DUKO LifeDUKO Life
Avidity Science Geno CL clinical laboratory reagent water system

Avidity Science

Geno CL

Geno CL is a centralized clinical laboratory reagent water system that produces clinical laboratory reagent water (CLRW). With four capacity options from 50 to 200 liters per hour, RO/EDI cassette technology and a 10 inch touchscreen, it supplies high-throughput autoanalyzers.

Request a quote
Water typeCLRW (clinical laboratory reagent water)
Capacity50 · 100 · 150 · 200 L/h
Water quality>10 MΩ·cm · TOC < 30 ppb · bacteria < 10 CFU/mL
Display10 inch touchscreen
DesignSingle cabinet, service access on castors

Geno CL as a clinical laboratory reagent water system

Clinical chemistry and immunology analyzers require a continuous supply of water of defined quality for reagent preparation and washing. The CLRW quality used for this purpose is defined in the CLSI document GP40. Geno CL produces this water in a single cabinet and delivers it to the analyzer.

Capacity can be selected in four steps from 50 to 200 L/h. When the laboratory grows or the number of analyzers increases, the system can be upgraded thanks to its dual-stream RO/EDI cassette design.

The dual-stream design also provides redundancy. If one cassette goes offline, the system does not stop completely; this is important to keep testing uninterrupted in a clinical laboratory. Other sector-specific requirements are summarized on the applications page.

Monitoring and data logging

The 10 inch touchscreen uses an icon-based interface. Built-in maintenance videos are also available on the unit, reducing the training burden when staff change.

Data logs can be transferred to cloud storage over a secure connection. This feature is used directly when water quality records must be presented during an accreditation audit.

Password-protected access and prioritized alarm notifications are provided. For example, a non-critical warning does not appear on screen with the same weight as a fault that would stop testing.

Keeping water quality records together with analyzer calibration and control records allows the source of an unexpected result deviation to be found quickly.

Installation and dimensions

The cabinet measures 1852 × 750 × 600 mm, with an operating depth of 800 mm. Net weight is 182 kg and operating weight is 292 kg. An area of 450 × 800 mm must be left free for maintenance access.

Feed water must be at 1–6 bar pressure; the flow rate is 190 L/h for the 50 and 100 CL models and 380 L/h for the 150 and 200 CLD models. Hardness is required to be below 20 ppm and free chlorine below 0.2 ppm. If mains water exceeds these values, pre-softening is required.

In clinical installations, the water system is placed in a technical area with service access rather than next to the analyzer. Planning the layout before ordering the unit avoids the cost of running pipework later.

Selection criteria for a clinical water system

This is a centralized system; installation, commissioning and periodic maintenance are carried out according to plan. Who will perform the installation and within what time frame is stated in writing at the quotation stage.

The water quality requirement defined by the analyzer manufacturer should be shared at the quotation stage, because not every system that meets the CLRW requirement can deliver the flow rate each analyzer needs; quality and flow rate are therefore checked together. Other centralized solutions are listed in the reverse osmosis and centralized systems section.

Technical specifications

Water typeCLRW: clinical laboratory reagent water
ModelsGENO 50 CL · 100 CL/CLD · 150 CLD · 200 CLD
Production rate50 · 100 · 150 · 200 L/h (20 °C)
Inorganic> 10 MΩ·cm (25 °C)
Organic (TOC)< 30 ppb
Bacteria< 10 CFU/mL
Particles0.2 µm filter
Silica< 0.05 mg/L
Dispense flow rate7.5 L/min (1 bar)
Feed water1–6 bar · 10–2,000 µS/cm · hardness < 20 ppm · free chlorine < 0.2 ppm · pH 4–10
Dimensions (H×W×D)1852 × 750 × 600 mm
Weight182 kg (net) · 292 kg (operating)
Electrical110–230 V, 50/60 Hz, max. 1,160 W
Display10 inch touchscreen, icon-based
DataCloud-connected logging, password-protected access

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is CLRW?

CLRW (Clinical Laboratory Reagent Water) is the class of reagent water used in clinical laboratories for reagent preparation and analyzer supply. At the Geno CL outlet, values of resistivity above 10 MΩ·cm, TOC below 30 ppb and bacteria below 10 CFU/mL are specified.

Can the capacity of Geno CL be increased later?

The dual-stream RO/EDI cassette design allows the system to be upgraded when the number of analyzers increases. Upgrade options and transitions between models are determined at the quotation stage.

What infrastructure must be prepared for installation?

Feed water at 1–6 bar pressure, a flow rate of 190 or 380 L/h depending on the model, a drain and an area of 450 × 800 mm for maintenance access are required. Pre-softening should be planned where mains water hardness exceeds 20 ppm.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote