Even if a coating has the correct color and gloss, it is not adequate if it cracks when the substrate is bent. These instruments measure the mechanical durability of the coating.

The impact test is performed by dropping a defined weight from a defined height and checking whether the coating cracks. The mandrel test measures flexibility by bending the panel over a cylindrical or conical mandrel. The cross-cut test evaluates resistance to detachment from the substrate based on flaking in a grid pattern cut into the coating.

These tests are included in customer specifications for automotive, household appliance, metal packaging and general industrial paints.

Selection criteria for coating durability testers

  • The standard to be followed and the geometry it requires
  • Size and thickness of the test panel
  • Measuring range: impact energy, mandrel diameters
  • How the results will be reported

The standard defined in the customer specification needs to be provided to us. The instrument is selected according to the geometry of the standard; a similar instrument is not sufficient.

Mandrel, cross-cut and impact test options

The catalog models and their key technical values are listed below. The full technical table and current pricing are provided in the quotation.

  • Cylindrical Mandrel Tester: "Quick and easy to use." · "12 stainless steel mandrels of different diameters: Ø2, Ø3, Ø4, Ø5, Ø6, Ø8, Ø10, Ø12, Ø16, Ø20, Ø25, Ø32 mm" · "All mandrels are precision-machined from high-hardness stainless steel; the 2 mm and 3 mm mandrels are hardened"
  • Conical Mandrel Tester: Size: 300 mm × 120 mm × 80 mm · Weight: 8 kg · Mandrel diameter: 3.1 ± 0.1 mm to 38 ± 0.1 mm
  • Cross Hatch Adhesion Tester, option 1: Number of teeth: 6 · Number of cutting edges: 8 · Cutting tooth spacing: 2 mm
  • Cross Hatch Adhesion Tester, option 2: Number of teeth: 6 · Cutting edges: 8 · Cutting tooth spacing: 1 mm
  • Impact Tester: Features: "Height-limiting ring/collar (stop) allows the operator to set different impact depths. / The aluminum oxide guide tube is manufactured with special technology and never fades or rusts. / The guide tube is produced in a special mold, and the clearance with the weight is precisely controlled." · Instrument scale length: 0–100 cm (40 in) · Standard weights: indented main weight 1000 g (1 pc); additional weight 1000 g (1 pc); additional weight 2000 g (1 pc)

Technical considerations

Test panels and reference specimens are separate items.

Most of these instruments are mechanical and have a long service life. Calibration and verification requirements are specified in writing at the quotation stage.

These tests are defined in ISO 6272-1 (impact), ISO 1519 (cylindrical mandrel) and ISO 2409 (cross-cut) respectively. When test panels are prepared with a paint film applicator, film thickness is kept constant; other products are in the coating and durability testing category.

Frequently asked questions

What is the difference between cylindrical and conical mandrel tests?

In the cylindrical mandrel test, the panel is bent successively over mandrels of different diameters and the smallest diameter at which the coating does not crack is determined. A conical mandrel covers small and large diameters together in a single bend, so the point where cracking begins is visible on one panel.

How is the 1 mm or 2 mm tooth spacing selected for the cross-cut test?

Tooth spacing is selected according to coating thickness and substrate hardness. Narrow spacing is used for thin coatings and wider spacing for thicker coatings; the spacing to be used is specified in the test standard or customer specification.

How is the impact test result evaluated?

After impact, the coating surface is inspected for cracking, lifting or detachment from the substrate. The result is usually reported as the highest drop height or impact energy at which the coating remains undamaged.