Geno II T
Geno II T is a Type 2 pure water system with a 35 liter reservoir integrated into the housing. It produces 10 or 20 liters per hour and is designed for laboratories that have no room for a separate tank.
Request a quote| Water type | Type 2 (deionized) |
|---|---|
| Production rate | 10 or 20 L/h |
| Reservoir | 35 liters, integrated |
| Water quality | 1–15 MΩ·cm |
| Power | Below 60 W while processing water |
Geno II T as a Type 2 pure water system with integrated reservoir
Geno II T fits the same purification train as Geno II into a smaller housing with an integrated reservoir. No separate tank is needed; the unit is placed on the bench or hung on the wall, and the water is ready for use.
The system is suitable for laboratories with a daily consumption in the 100–200 liter range. Water used for buffer preparation, dilution, spectrophotometry, electrophoresis and glassware rinsing falls into this class.
Power consumption is below 60 W while processing water. In addition, the quiet internal pump and vibration-isolated mounting do not disturb staff working in the same room.
Operation and maintenance
The touchscreen shows the current water quality and the volume in liters in the reservoir. The interface is simple enough to be read without removing gloves.
The modules are designed to be replaced by the user. The manufacturer recommends mechanical maintenance by trained service personnel once a year.
- TC021 / TC022: Pretreatment module (for 10 and 20 L/h models)
- TC023: DI cartridge (2 per year)
- TC024: Tank air filter
- TC025: UV lamp (optional)
The current list of these codes is available on the pure water cartridges and filters page.
The unit is supplied with its first set of consumables, so operation can begin after installation without waiting for additional materials.
Correct use and common mistakes
Water that stands in the reservoir for a long time gradually absorbs carbon dioxide and particles from the air; the reservoir volume should therefore be matched to daily consumption. In laboratories with low consumption, regular use of the water helps maintain quality.
The tank air filter limits contaminants in the air entering the reservoir; if its replacement is delayed, the quality of the stored water decreases. Likewise, failing to replace the pretreatment module on time causes the DI cartridge to be exhausted earlier than expected.
Another common mistake is using Type 2 water for tasks that require Type 1, such as HPLC mobile phase or cell culture. A separate ultrapure water supply should be planned for these tasks.
Selection criteria for a Type 2 pure water system with reservoir
If daily consumption exceeds 200 liters, this model approaches its capacity limit; in that case, a Geno II with a separate reservoir is the better choice. If consumption has not been measured, simply recording the number of containers filled over one week provides an adequate starting point.
Dimensions are 500 × 485 × 330 mm and the weight is 20 kg. For wall mounting, it should be checked whether the wall can carry the load, because the filled weight increases by the weight of 35 liters of water.
If there are also tasks that require Type 1 water, such as HPLC or cell culture, a combined solution should be considered. Other options are listed in the Type 2 pure water systems section.
Technical specifications
| Water type | Type 2 (deionized) |
|---|---|
| Models | Geno II T 10 (10 L/h) · Geno II T 20 (20 L/h) |
| Water quality | 1–15 MΩ·cm |
| Inorganic removal | 98% |
| TOC reduction | 96% (UV model) |
| Daily capacity | 100 L (T 10) · 200 L (T 20) |
| Integrated reservoir | 35 liters |
| Feed water | 0.1–6 bar · < 1,400 µS/cm · 4–30 °C · hardness < 400 ppm · pH 4–10 |
| Dimensions (H×W×D) | 500 × 485 × 330 mm |
| Installed weight | 20 kg |
| Electrical | 100–240 V, 50/60 Hz, max. 1.5 A |
| Mounting | Bench or wall |
| Manufacturing standard | ISO 9001:2015 certified manufacturing |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
What is the difference between Geno II T and Geno II?
Geno II T carries a 35 liter reservoir in its housing and produces 10 or 20 liters per hour. Geno II produces 25 or 45 liters per hour and is installed with a separate 30, 60 or 100 liter reservoir. Geno II T is suitable for limited spaces and daily consumption of up to 200 liters.
Can Geno II T be wall-mounted?
Yes, bench or wall mounting is possible. For wall mounting, the load capacity of the wall should be checked in advance, since the weight of 35 liters of water is added to the unit's 20 kg.
Which consumables are replaced regularly on Geno II T?
The pretreatment module, the DI cartridge (replaced twice a year) and the tank air filter are the regular consumables; the UV lamp is optional. Replacement frequency depends on feed water quality and usage volume.