DUKO LifeDUKO Life
Dohmeyer cryogenic spiral freezer

Dohmeyer

Cryogenic Spiral Freezer

The cryogenic spiral freezer continuously processes products that require long freezing times in a small footprint, with capacity up to 5000 kg/h and retention times of up to 4 hours.

Request a quote
CapacityUp to 5000 kg/h
Retention time20 minutes to 4 hours
RefrigerantLiquid nitrogen (-196 °C) or liquid CO2 (-78 °C)
ControlPLC and HMI, recipe storage
Protection ratingIP69K

Product description

The cryogenic spiral freezer is a continuously operating industrial line in which the product is frozen with liquid nitrogen or liquid CO2 as it travels up or down on a conveyor belt wound in a spiral. Since the belt length is concentrated along the vertical axis, long retention times are achieved in a much smaller footprint than with a straight tunnel. Capacity reaches up to 5000 kg/h.

The retention time is adjustable between 20 minutes and 4 hours. For this reason, the spiral freezer is preferred for products that require a longer retention time than a tunnel offers, such as thicker portions.

Applications

  • Food products requiring a longer retention time than a tunnel provides
  • High-volume, continuous food freezing lines
  • Production facilities with limited floor space
  • Production in which different products are processed on the same line with stored recipes

Effect of cryogenic freezing in the spiral freezer

The heat transfer coefficient in cryogenic freezing is 100–140 W/m²·K; in mechanical forced-air systems this value is 15–17 W/m²·K. As a result, freezing time is shortened by more than about 75%. For example, 50 g of bread freezes in 4 minutes with the cryogenic method and in 18 minutes with the mechanical method; 50 g of mozzarella freezes in 5 and 22 minutes, respectively.

According to the manufacturer's data, the spiral freezer takes up to 75% less space than a mechanical tunnel and keeps product moisture loss below 0.5%; in mechanical systems this loss is around 3–5%. Also according to the manufacturer's data, the isothermal design increases heat transfer by about 15%. Ice crystals below 10 µm formed during fast freezing help preserve texture and appearance after thawing.

Technical assessment

The line is controlled by a PLC and operated via an HMI screen. With recipe storage, settings such as belt speed and temperature can be saved and recalled for different products. The N+1 safety circuit is a redundant design intended to maintain safe operation even if a critical component fails. The IP69K protection rating indicates resistance to washdowns with high-pressure hot water.

Spiral diameter, number of tiers, belt width and refrigerant consumption are not published values; this information is confirmed with the manufacturer's data sheet at the quotation stage.

Selection criteria

When choosing between a spiral and a tunnel, the retention time required by the product is considered first. For thin products that freeze in a few minutes, the cryogenic tunnel freezer is usually sufficient; when long retention time, high hourly capacity and limited floor space all apply, the spiral design stands out. Liquid nitrogen provides deeper cooling down to -196 °C, while liquid CO2 is limited to -78 °C.

With cryogenic lines, the investment cost is usually lower than for a mechanical system, while the operating cost is higher due to gas consumption. Other line options are listed on the cryogenic lines page.

Technical specifications

ManufacturerDohmeyer
Operation typeContinuous, spiral conveyor
CapacityUp to 5000 kg/h
Retention time20 minutes to 4 hours
RefrigerantLiquid nitrogen (-196 °C) or liquid CO2 (-78 °C)
ControlPLC and HMI, recipe storage
SafetyN+1 safety circuit
Protection ratingIP69K
Space requirementUp to 75% less than a mechanical tunnel, according to the manufacturer's data
Moisture lossBelow 0.5%, according to the manufacturer's data
Spiral diameter, number of tiers, belt widthConfirmed with the manufacturer's data sheet at the quotation stage

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

When is a spiral freezer preferred over a tunnel?

If the product requires a retention time between 20 minutes and 4 hours, hourly capacity is high and floor space is limited, the spiral freezer is the more suitable option.

How does the cryogenic spiral freezer affect product weight loss?

According to the manufacturer's data, moisture loss stays below 0.5%; in mechanical systems this value is around 3–5%. Lower moisture loss helps preserve the quantity of saleable product.

Should liquid nitrogen or liquid CO2 be chosen?

Liquid nitrogen provides deeper and faster cooling down to -196 °C; liquid CO2 is limited to -78 °C. The choice is made at the quotation stage according to the product, target temperature and the facility's gas supply infrastructure.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote