DUKO LifeDUKO Life
CryoXpert cabinet pharmaceutical blast freezer

Dohmeyer

CryoXpert Cabinet Pharmaceutical Blast Freezer

The CryoXpert cabinet pharmaceutical blast freezer doses liquid nitrogen through vacuum-insulated proportional valves and freezes pharmaceutical liquids at a rate adjustable from 0.1 to 60 °C/min.

Request a quote
Cooling rate0.1–60 °C/min
RefrigerantLiquid nitrogen, proportional valve control
ModelsCXP-PBF-2300, CXP-PBF-3300
SafetyN+1 safety circuit, magnetic door lock
Compliance21 CFR Part 11, ISO 13485, GMP

Product description

A pharmaceutical blast freezer is an industrial cabinet that brings large volumes of pharmaceutical liquids below the freezing point quickly and in a controlled manner. Fast freezing limits the formation of large ice crystals that can damage cell and protein structure. In cryogenic freezing, intracellular crystals remain below 10 µm, whereas in mechanical systems they can exceed 50 µm.

The CryoXpert cabinet model is the solution for large batches in Dohmeyer's medical series. The cabinet has a wide door opening 2000 mm high. Cooling is achieved by dosing liquid nitrogen through vacuum-insulated proportional valves, and the rate is programmed in the range of 0.1–60 °C/min.

Applications

  • Freezing of pharmaceutical liquids containing active ingredients and intermediates
  • Bulk freezing in bags and large plastic bottles
  • Shelf freezing of vial batches inside the cabinet
  • Pharmaceutical processes from R&D to clinical production

Technical assessment

Because the proportional valves continuously adjust the nitrogen flow, the profile is followed more smoothly than in systems that operate fully open or fully closed. The magnetic door lock prevents the door from being opened during the process; the heated lid limits icing. The N+1 safety circuit ensures that a backup circuit takes over if a critical component fails.

Access is authorized by RFID card. 21 CFR Part 11 compliant software records all operations in the audit trail and generates an encrypted PDF report; a UPS protects the control system against power failures. The general advantages of cryogenic freezing are summarized on the technologies page.

Manufacturer sources give inconsistent values for the cabinet volume. For this reason, internal dimensions are used instead of volume; the exact volume and minimum operating temperature are confirmed with the manufacturer's data sheet at the quotation stage.

Installation, safety and maintenance

Since a cabinet blast freezer uses a significant amount of liquid nitrogen for large batches, the facility's nitrogen tank capacity and filling frequency should be evaluated together with the batch plan. Mechanical ventilation and an oxygen sensor in the area where the unit is located, and venting of evaporated nitrogen to the outside through the exhaust, are basic safety requirements.

In pharmaceutical production, the cabinet is qualified after installation through IQ/OQ/PQ steps, and temperature mapping is performed with an empty and a loaded chamber. Product probes and proportional valves should be included in the periodic maintenance plan, and door seals should be checked regularly for icing and wear.

Selection criteria

The main difference between the two models is the door opening and internal width. The CXP-PBF-2300 offers a door width of 850 mm and the CXP-PBF-3300 a door width of 1050 mm; both models have an internal height of 1900 mm. Selection takes into account the size of the loading equipment, the quantity of product per batch and the ceiling height of the facility.

For smaller batches or laboratory scale, the CryoXpert chest controlled-rate freezer is a suitable starting point.

Technical specifications

ManufacturerDohmeyer (CryoXpert series)
Cooling rate0.1–60 °C/min
Nitrogen controlVacuum-insulated proportional valves
CXP-PBF-2300 door opening850 × 2000 mm
CXP-PBF-2300 internal dimensions1360 × 850 × 1900 mm (D × W × H)
CXP-PBF-2300 external dimensions1800 × 2480 × 2550 mm
CXP-PBF-3300 door opening1050 × 2000 mm
CXP-PBF-3300 internal dimensions1560 × 1050 × 1900 mm (D × W × H)
CXP-PBF-3300 external dimensions2000 × 2680 × 2550 mm
DoorMagnetic lock, heated lid
SafetyN+1 safety circuit, UPS
Access and dataRFID, 21 CFR Part 11, encrypted PDF report
Quality systemGMP, ISO 13485
Volume, minimum temperatureConfirmed with the manufacturer's data sheet at the quotation stage

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Are blast freezing and controlled-rate freezing the same thing?

This cabinet offers both: because the rate is adjustable in the range of 0.1–60 °C/min, both slow, programmed profiles and fast blast freezing can be applied. The appropriate profile is determined by the product formulation.

Which containers can be frozen?

It is designed for vials, bags, large plastic bottles and pharmaceutical liquids.

Why is the cabinet volume not given in liters?

Since manufacturer sources give different volume values, internal dimensions are used instead. The exact volume is confirmed with the manufacturer's data sheet at the quotation stage.

Is there moisture loss during freezing?

Most moisture loss occurs between -1 and -5 °C. Cryogenic systems pass through this zone in less than 3 minutes, keeping the loss below 1%; in mechanical systems this takes 10–30 minutes and the loss is around 3–5%.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote