CryoXpert carousel controlled-rate freezer

Dohmeyer

CryoXpert Carousel Controlled-Rate Freezer

The CryoXpert carousel controlled-rate freezer operates with liquid nitrogen, and its largest model freezes more than 40,000 standard 2 mL vials in a single batch while maintaining the cold chain.

Request a quote
Capacity10,000, 20,000 and 40,000 vials (2 mL)
RefrigerantLiquid nitrogen
ShelvingRotating carousel
DefrostingAutomatic defrost
Compliance21 CFR Part 11, ISO 13485, GMP

Product description

A controlled-rate freezer aims to preserve cell and active ingredient structure by cooling the product according to a defined temperature profile. With vaccines and cell-based products, the larger the batch, the harder it becomes for every vial to experience the same conditions; for this reason, distribution within the chamber and the access arrangement become critical in high-capacity systems.

The CryoXpert carousel model is a cabinet-type solution in Dohmeyer's medical series developed for high-volume production. The shelves are arranged as a carousel; this design provides access to individual samples while helping to maintain the cold chain. The largest model holds more than 40,000 standard 2 mL vials in a single batch.

Applications

  • Freezing of vial and ampoule batches in vaccine production
  • Bulk freezing of high-count vial and ampoule batches
  • Cryopreservation of gametes and embryos

Technical assessment

Liquid nitrogen is fed into the chamber through a vacuum-insulated manifold. A proportional process valve on the manifold adjusts the nitrogen flow according to the profile, while a separate safety shut-off valve cuts the supply in an unexpected situation. Vacuum insulation reduces heat gain in the line, helping the nitrogen reach the chamber in liquid form.

The automatic defrost function removes ice that accumulates on chamber surfaces between consecutive batches and keeps maintenance intervals regular. Access is restricted by an RFID card panel; 21 CFR Part 11 compliant software maintains an audit trail and generates encrypted PDF reports. UPS support keeps the control system running during a power failure.

The cooling rate and minimum operating temperature have not been published for this model. Suitability for the target freezing profile is confirmed with the manufacturer's data sheet at the quotation stage.

Installation, safety and process integration

The most important safety issue with liquid nitrogen freezers is that nitrogen gas accumulating in an enclosed space dilutes the oxygen in the air. For this reason, the room housing the unit should have mechanical ventilation and a fixed oxygen sensor, and the exhaust line should be vented to the outside. In addition, keeping the line from the liquid nitrogen tank to the unit short reduces both heat gain and nitrogen loss.

In a GMP environment, the unit is commissioned after installation through installation, operational and performance qualification (IQ/OQ/PQ) steps; the temperature distribution in the chamber is documented by a mapping study. Routine maintenance includes checking seals, valves and the calibration status of the probes.

Capacity planning for controlled-rate freezer selection

The model is selected according to the number of vials to be frozen in a single batch. The 10,000-vial model is 2240 mm wide and the 40,000-vial model 3140 mm wide; all models are 2320 mm high. Before installation, door clearance, ceiling height and the routing of the liquid nitrogen line should be checked.

If bags or large bottles are to be frozen instead of vials, the CryoXpert cabinet pharmaceutical blast freezer can be considered.

For smaller batches, the CryoXpert chest-type model is a suitable starting point. All models in the series are listed in the controlled-rate freezing systems section.

Technical specifications

ManufacturerDohmeyer (CryoXpert series)
RefrigerantLiquid nitrogen
CXP-CAB-10K2240 × 1350 × 2320 mm (W × D × H), 10,000 vials
CXP-CAB-20K2540 × 1550 × 2320 mm (W × D × H), 20,000 vials
CXP-CAB-40K3140 × 2260 × 2320 mm (W × D × H), 40,000 vials
Vial referenceStandard 2 mL vial
ShelvingCarousel, individual sample access
Nitrogen supplyVacuum-insulated manifold, proportional process valve, safety shut-off valve
DefrostingAutomatic defrost
Access and dataRFID panel, 21 CFR Part 11, encrypted PDF report
Power securityUPS
Quality systemISO 13485, GMP
Cooling rate, minimum temperatureConfirmed with the manufacturer's data sheet at the quotation stage

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the purpose of the carousel design?

The carousel arrangement provides access to individual samples in the batch while helping to maintain the cold chain. Details of the access arrangement are confirmed with the manufacturer's data sheet at the quotation stage.

Which containers can it be used with?

The model is primarily designed for vials and ampoules. Capacity values are based on standard 2 mL vials; loading for other sizes is evaluated at the quotation stage.

How does it differ from a mechanical freezer?

In cryogenic systems, the heat transfer coefficient is in the range of 100–140 W/m²·K; in mechanical forced-air systems this value remains around 15–17 W/m²·K. Faster heat removal ensures short freezing times even with large batches.