
DLAB
DCP and DUC Recirculating Chiller
The DCP series laboratory recirculating chiller cools the coolant down to -20 °C and pumps it to a rotary evaporator condenser, reactor jacket or external equipment. In addition to models with 4.5 L, 17 L and 20 L tanks, the series includes the DUC-10 chiller with ±0.1 °C precision; the models are listed by the manufacturer as coming soon.
Request a quote| Temperature range | -20 °C to room temperature (DCP) · 5–35 °C (DUC-10) |
|---|---|
| Cooling capacity (20 °C) | 700 W · 2,400 W · 3,200 W · 1,000 W (DUC-10) |
| Pump flow rate | 22 L/min (DCP) · adjustable 2–20 L/min (DUC-10) |
| Tank volume | 4.5 L · 17 L · 20 L · 7 L (DUC-10) |
| Temperature accuracy | ±0.3–0.5 °C (DCP) · ±0.1 °C (DUC-10) |
Product description
A laboratory recirculating chiller cools the fluid in its own tank and pumps it into an external circuit. On a rotary evaporator, this circuit is the condenser; the cold condenser condenses the evaporated solvent and recovers it in the receiving flask. Compared with cooling by tap water, the temperature remains constant and water consumption is eliminated.
The DCP series operates between -20 °C and room temperature. The temperature is held by a PT100 sensor and intelligent PID control; the display shows values with 0.1 °C resolution. The tank is filled from the top and drained from the rear; a level window at the front and overflow protection simplify everyday use.
The DUC-10 is a chiller targeting ±0.1 °C precision in the 5–35 °C range. It adjusts compressor output with a hot gas bypass and proportional cooling system, the pump flow rate can be varied between 2 and 20 L/min, and it is controlled via a 3.5-inch touchscreen.
Model comparison
| Model | Temperature range | Cooling capacity | Tank | Pump pressure | Accuracy |
|---|---|---|---|---|---|
| DCP-5 (coming soon) | -20 °C to room temperature | 700 W | 4.5 L | 0.3 bar | ±0.3 °C |
| DCP-17 (coming soon) | -20 °C to room temperature | 2,400 W | 17 L | 1.0 bar | ±0.5 °C |
| DCP-20 (coming soon) | -20 °C to room temperature | 3,200 W | 20 L | 1.0 bar | ±0.5 °C |
| DUC-10 (coming soon) | 5–35 °C | 1,000 W | 7 L | 1.3 bar | ±0.1 °C |
Cooling capacities are given for 20 °C; capacity decreases at lower temperatures. The refrigerant is R290 on the DCP-5 and DCP-17, R404A on the DCP-20, and R134a or optionally R1234yf on the DUC-10.
Applications
- Cooling of rotary evaporator condensers
- Providing a constant low temperature for reactor jackets and external heat exchangers
- Control of temperature-sensitive processes in pharmaceutical and chemistry laboratories
- Precision cooling in semiconductor and electronics applications (DUC-10)
Laboratory recirculating chiller selection criteria
- Cooling capacity: The condenser load increases with the amount of solvent evaporated and the bath power; for large-volume evaporators, a high-capacity model is considered.
- Target temperature: For low-boiling solvents, the DCP models reaching -20 °C are suitable; for applications requiring a constant and precise temperature, the DUC-10 is suitable.
- Circuit length: With long hose lines, pump pressure and pump head become important; the DCP-17 and DCP-20 have a pump head of 25 m.
- Power supply: The DCP-5 operates at 100/120 V, and the DCP-17 and DCP-20 at 200–240 V; the supply voltage is confirmed before ordering.
The chiller is used together with the RE100 laboratory rotary evaporator and pilot scale rotary evaporators; on the vacuum side, the C410 chemical diaphragm pump completes the system. Other options are found in the rotary evaporators and chillers category.
Technical specifications
| Temperature control | Intelligent PID, PT100 sensor |
|---|---|
| Display resolution | 0.1 °C |
| Display | LED (DCP) · 3.5-inch LCD touchscreen (DUC-10) |
| Refrigerant | R290 (DCP-5, DCP-17) · R404A (DCP-20) · R134a or R1234yf (DUC-10) |
| Maximum pump pressure | 0.3 bar (DCP-5) · 1.0 bar (DCP-17, DCP-20) · 1.3 bar (DUC-10) |
| Pump head | 5 m (DCP-5) · 25 m (DCP-17, DCP-20) |
| Hose connection | 8 mm ID (DCP-5) · 10 mm ID (others) |
| Installation | Floor-standing type |
| Continuous operation | 100% |
| Power supply | 100/120 V, 50/60 Hz (DCP-5) · 200–240 V, 50 Hz (DCP-17, DCP-20) · 100–120 V 60 Hz or 220–240 V 50 Hz (DUC-10) |
| Power | Max. 700 W (DCP-5) · 1,000 W (DCP-17) · 1,500 W (DCP-20) · 650 W (DUC-10) |
| Dimensions (W × D × H) | 230 × 490 × 450 mm (DCP-5) · 400 × 560 × 705 mm (DCP-17) · 450 × 600 × 1,100 mm (DCP-20) · 310 × 650 × 530 mm (DUC-10) |
| Ambient conditions | 5–40 °C, 80% relative humidity |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
What does a recirculating chiller offer compared with cooling by tap water?
The condenser temperature remains constant regardless of the seasonally varying tap water temperature; low-boiling solvents condense more efficiently and continuous running water is not required.
What is the difference between the DUC-10 and the DCP models?
The DCP models are general-purpose chillers cooling down to -20 °C. The DUC-10 is a precision chiller offering ±0.1 °C precision in the 5–35 °C range, adjustable pump flow rate and a touchscreen.
When will these models be available?
The series is listed by the manufacturer as coming soon. The delivery schedule and current technical data are confirmed at the quotation stage.
From the same category

C410 Chemical Diaphragm Vacuum Pump and VC100 Vacuum Controller
Chemical diaphragm pump reaching 13 mbar and programmable VC100 controller for rotary evaporation and vacuum filtration.

RE100 Series Rotary Evaporator
Laboratory rotary evaporators working with 50–3,000 mL flasks, with a heating bath from room temperature to 180 °C.

RE200-Pro and RE-E Pilot Scale Rotary Evaporator
Rotary evaporators with flask volumes from 5 L to 50 L for pilot production and large-volume solvent recovery.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote