puriFlash XS-Vap parallel evaporator

Advion Interchim Scientific

puriFlash XS-Vap

puriFlash XS-Vap is a parallel evaporator that evaporates solvent from up to 90 samples simultaneously using nitrogen flow and a heated water bath. It works with a range of tube and vial sizes from 1 mL to 250 mL.

Request a quote
CapacityUp to 90 samples simultaneously
Volume1 mL–250 mL
HeatingHeated water bath
GasNitrogen, recommended 3 bar (max. 6 bar)
Weight35 kg

Product description

After purification, solvent must be removed from a large number of fractions. On a rotary evaporator, this is done sample by sample and takes hours. XS-Vap directs nitrogen onto the sample surfaces and evaporates up to 90 samples simultaneously.

While the heated water bath warms the samples from below, the nitrogen flow removes vapor from the liquid surface; the combination of the two effects accelerates evaporation.

Needle height is adjusted manually, and nitrogen flow is monitored with the control valve and pressure gauge on the instrument. The evaporation program is entered via the integrated display.

Compatible vessel and tube sizes

The instrument works with a wide range of tubes and vials; compatibility of the vessels to be used is checked before ordering.

  • 250 mL bottle (tapered or straight)
  • 18 × 150 mm (25 mL tube) · 16 × 150 mm (22 mL) · 16 × 100 mm (12 mL) · 13 × 100 mm (10 mL)
  • 17 × 60 mm (8 mL vial) · 15 × 45 mm (4 mL vial) · 12 × 32 mm (2 mL vial)
  • 2 mL microcentrifuge tubes
  • Other sizes on request

Advantages of the parallel evaporator

In laboratories performing flash purification, the bottleneck is usually not the purification itself but the subsequent solvent removal step; while purification is completed in an hour, drying the fractions can take hours.

Parallel evaporation eliminates this bottleneck. As the samples are dried under the same conditions, drying-related variation between samples is also reduced.

Nitrogen consumption is a significant operating cost with these instruments. The cost difference between a nitrogen generator and nitrogen cylinders can be analyzed at the quotation stage according to the intensity of use.

Use with purification systems

XS-Vap is designed for batch drying of fractions generated after flash and preparative purification. For example, the 18 × 150 mm tubes used in the fraction collector of the puriFlash XS 530 or puriFlash 5.020 can be transferred to the instrument and dried directly. Fractions are thus processed without transfer to another vessel, reducing the risk of sample loss.

For laboratories working with a small number of samples, the six-position puriVap 6 nitrogen evaporator is better suited in scale. All models are in the parallel evaporators section.

Correct use and common mistakes

Keeping the nitrogen pressure higher than necessary increases the risk of splashing and nitrogen consumption. The flow should therefore be increased gradually, and the needle height readjusted as the liquid level drops. The water bath temperature should also be selected taking into account the boiling point of the solvent and the thermal stability of the sample.

Technical considerations for the parallel evaporator

The instrument is certified under CE in accordance with the low voltage and electromagnetic compatibility directives. If required, the declaration of conformity is provided with the quotation.

The nitrogen line, regulator and fittings should be included in the quotation; the condition of the existing installation is checked before installation.

Technical specifications

CapacityUp to 90 samples simultaneously
Volume range1 mL–250 mL
HeatingHeated water bath
ControlProgram via integrated display
Needle systemManual height adjustment
Gas supplyNitrogen; maximum 6 bar, recommended 3 bar
Power100–120 V or 220–240 V
Dimensions37 × 40 × 60 cm (W × D × H)
Weight35 kg
CertificationCertified under 2014/35/EU (LVD) and 2014/30/EU (EMC)

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between XS-Vap and a rotary evaporator?

A rotary evaporator processes samples one at a time. XS-Vap evaporates up to 90 samples simultaneously using nitrogen flow and a heated water bath, which saves time in laboratories drying many fractions.

Which vessel sizes can be used?

Tubes, vials and bottles from 1 mL to 250 mL can be used. Supported sizes include, for example, 18 × 150 mm tubes, 2–8 mL vials, 250 mL bottles and 2 mL microcentrifuge tubes.

What nitrogen supply is required?

The recommended nitrogen pressure for the instrument is 3 bar, with a maximum of 6 bar. A nitrogen generator or cylinders can be used; the choice is based on a cost comparison according to the intensity of use.