Avidity Science
Alto I
Alto I is a Type 1 ultrapure water system fed from an existing RO or deionized water line. It dispenses at up to 2 liters per minute with 18.2 MΩ·cm resistivity and TOC below 5 ppb; a 185/254 nm dual-wavelength UV lamp is standard.
Request a quote| Water type | Type 1 ultrapure |
|---|---|
| Quality | 18.2 MΩ·cm · TOC ≤ 5 ppb |
| Dispensing | Up to 2 L/min |
| Volumetric dispensing | 0.1–25 liters |
| Feed | RO, distilled or deionized water |
Alto I as a Type 1 ultrapure water system
Alto I is a polishing system that takes pretreated water and converts it into Type 1 ultrapure water. It can receive feed water from Geno II, the Puro III reverse osmosis water system or the laboratory's existing RO line.
Ultrapure water is defined by parameters beyond conductivity. At the Alto I outlet, the water has 18.2 MΩ·cm resistivity, TOC below 5 ppb, bacteria below 1 CFU/mL and particles below 0.22 µm.
The dual-wavelength UV lamp (185 and 254 nm) both breaks down organic matter and keeps the microbial load under control. The UV lamp is therefore the key element that keeps Type 1 water quality consistent.
Applications
- Molecular biology, immunology and pharmacology
- Cell and tissue culture
- Mobile phase and dilution water for HPLC, IC, GC, MS and ICP-MS
- Graphite furnace atomic absorption
- DNA sequencing, genomics and proteomics
- Electrochemistry
The UF model also guarantees endotoxin, RNase, DNase and protease levels. The UF model is therefore preferred for cell culture and RNA work.
Installation and consumables
Benchtop, under-bench or wall mounting is possible. In addition to the integrated dispensing gun, up to two remote dispensing guns can be added.
The conductivity of the feed water must be below 40 µS/cm; the unit is therefore not connected directly to the mains. An RO or DI system is required upstream; if a Type 2 system is already in place, Alto I is installed on top of it.
- TC003: UV lamp (1 per year)
- TC009: Endure purification pack 2 (2 per year)
- TC004 / TC011: Point-of-use filter
- TC010: Sanitization pack
- AV018: IQ/OQ documentation
All of these consumables are listed on the pure water cartridges and filters page.
For a new installation from scratch, the Duo II·I combined system should also be considered instead of a Puro III and Alto I pair. This option is usually more advantageous in terms of space and initial investment.
Selection criteria for a Type 1 ultrapure water system
The first question in selection is the feed water: if the laboratory has an RO or Type 2 line, Alto I is connected directly to it. If there is no feed line, a unit that runs from the mains or a combined system is more suitable.
The second criterion is the application. For example, the standard model is sufficient for HPLC and ICP-MS, whereas the UF model is required for cell culture and RNA work. Other options are listed in the Type 1 ultrapure water systems section.
Technical specifications
| Water type | Type 1 ultrapure (ASTM Type 1) |
|---|---|
| Models | ALTO TOC · ALTO TOC UF |
| Water quality | 18.2 MΩ·cm (25 °C) |
| TOC | ≤ 5 ppb |
| Bacteria | < 1 CFU/mL |
| Particles | < 0.22 µm |
| Dispense rate | Up to 2 L/min |
| Volumetric dispensing | 0.1–25 liters |
| UF model | Endotoxin 0.001 EU/mL · RNase < 1 pg/mL · DNase < 5 pg/mL · protease < 0.15 µg/mL |
| UV | 185 / 254 nm dual wavelength |
| Feed water | RO, distilled or deionized · < 40 µS/cm · hardness < 20 ppm · 4–30 °C |
| Dimensions (H×W×D) | 500 × 490 × 290 mm |
| Installed weight | 23 kg |
| Electrical | 100–240 V, 50/60 Hz, max. 3.0 A |
| Mounting | Benchtop, under-bench or wall |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
Can Alto I be connected directly to mains water?
No. Alto I is a polishing system, and the conductivity of its feed water must be below 40 µS/cm. A system that supplies RO, distilled or deionized water is therefore required upstream.
What is the difference between ALTO TOC and ALTO TOC UF?
Both models deliver 18.2 MΩ·cm and TOC below 5 ppb. In addition, the UF model guarantees endotoxin, RNase, DNase and protease levels and is recommended for cell culture and RNA work.
How often is the UV lamp replaced?
The manufacturer recommends replacing the TC003 UV lamp once a year. A lit lamp is not sufficient on its own; its intensity decreases over time.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote