DLAB
DispensMate Bottle-Top Dispenser
The DLAB DispensMate series is a family of bottle-top dispensers mounted directly on the reagent bottle that deliver the set volume with every stroke. The standard model is designed for routine reagents, the Pro model for acids, bases and organic solvents, and the HF model for hydrofluoric acid.
Request a quote| Volume range | 0.5 mL to 100 mL (depending on model) |
|---|---|
| Systematic error | ±0.5% (at nominal volume) |
| Random error | ±0.2% (at nominal volume) |
| Autoclave | 121 °C |
| Adapters | S40, GL32, GL38, GL25, GL28 |
Product description
A bottle-top dispenser repeatedly dispenses reagent at the set volume without transferring it from the bottle to another container. This reduces the risk of chemical contact and spills, keeps the reagent bottle in a closed system and delivers the same volume with every dose.
The DLAB DispensMate series includes three models. The DispensMate, with PTFE, FEP, borosilicate glass and PP components, is designed for routine reagent dispensing. The DispensMate-Pro offers broader chemical compatibility with glass or PTFE piston options and is fully autoclavable. The DispensMate-HF is manufactured specifically for hydrofluoric acid with a high-purity ceramic piston and FEP tubing.
Model comparison
| Model | Volume ranges | Piston | Suitable reagents | Autoclave |
|---|---|---|---|---|
| DispensMate | 0.5–5 · 1–10 · 2.5–25 · 2.5–30 · 5–50 · 5–60 mL | Inert components (PTFE, FEP, borosilicate glass, PP) | Routine reagent dispensing | 121 °C (parts in contact with liquid) |
| DispensMate-Pro | 0.5–5 · 1–10 · 2.5–25 · 5–50 · 10–100 mL | Glass or PTFE; glass piston option for 5, 10, 25 mL | Acids, bases, salt solutions, organic solvents | 121 °C (fully) |
| DispensMate-HF | 1–10 mL | High-purity ceramic piston and cylinder | Hydrofluoric acid | - |
The published accuracy values of the standard DispensMate model are shown below; the Pro model has the same values in the shared volume ranges.
| Volume range | Graduation | Systematic error | Random error |
|---|---|---|---|
| 0.5–5 mL | 0.1 mL | ±25 µL (±0.5%) | ±10 µL (±0.2%) |
| 1–10 mL | 0.2 mL | ±50 µL (±0.5%) | ±20 µL (±0.2%) |
| 2.5–25 mL | 0.5 mL | ±125 µL (±0.5%) | ±50 µL (±0.2%) |
| 2.5–30 mL | 0.5 mL | ±150 µL (±0.5%) | ±60 µL (±0.2%) |
| 5–50 mL | 1.0 mL | ±250 µL (±0.5%) | ±100 µL (±0.2%) |
| 5–60 mL | 1.0 mL | ±300 µL (±0.5%) | ±120 µL (±0.2%) |
Applications
- Routine dispensing of acids, bases and salt solutions
- Sample preparation with organic solvents (DispensMate-Pro)
- Standard solution preparation and reagent dispensing under sterile conditions
- Hydrofluoric acid dosing in trace analysis preparation (DispensMate-HF)
Because hydrofluoric acid rapidly etches glass and poses a serious health risk, it is not dispensed with standard dispensers. On the DispensMate-HF, all parts in contact with liquid are made of ceramic and FEP materials resistant to this acid.
Bottle-top dispenser selection criteria
- Reagent: For routine aqueous reagents, the DispensMate is selected; for organic solvents, the DispensMate-Pro; for hydrofluoric acid, the DispensMate-HF.
- Volume: The model is chosen so that the most frequently dispensed dose falls in the upper half of the range.
- Bottle neck: The standard adapters fit S40, GL32, GL38, GL25 and GL28 necks.
- Sterilization: If sterile dispensing is required, the fully autoclavable Pro model is suitable.
For a motorized solution with the dose set on a display, the dFlow electronic dispenser, and for titration, the dTrite electronic burette should be considered. For small volumes, the StepMate repeater pipette can be used. Other products are found in the liquid handling category.
Technical specifications
| Volume ranges (DispensMate) | 0.5–5 · 1–10 · 2.5–25 · 2.5–30 · 5–50 · 5–60 mL |
|---|---|
| Volume ranges (DispensMate-Pro) | 0.5–5 · 1–10 · 2.5–25 · 5–50 · 10–100 mL |
| Volume range (DispensMate-HF) | 1–10 mL |
| Systematic error | ±0.5% (at nominal volume, DispensMate and Pro) |
| Random error | ±0.2% (at nominal volume, DispensMate and Pro) |
| DispensMate-HF accuracy (10 mL) | Systematic ±50 µL (±0.5%) · random ±20 µL (±0.2%) |
| Material (DispensMate) | PTFE, FEP, borosilicate glass, PP |
| Piston (DispensMate-Pro) | Glass or PTFE |
| Material (DispensMate-HF) | Ceramic piston, cylinder, valve ball and seat; FEP inlet and outlet tubing |
| Autoclave | 121 °C (Pro fully; parts in contact with liquid on the standard model) |
| Adapters | S40, GL32, GL38, GL25, GL28 |
| Standard (DispensMate-HF) | ISO 8655 |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
What is the difference between the DispensMate and the DispensMate-Pro?
The standard model is designed for routine aqueous reagents. The Pro model offers broader chemical compatibility, including organic solvents, with glass or PTFE piston options and is fully autoclavable.
Why does hydrofluoric acid require a separate dispenser?
Hydrofluoric acid etches glass. Standard dispensers containing a glass piston are therefore not used; the DispensMate-HF, whose parts in contact with liquid are ceramic and FEP, is preferred.
Which bottles does the dispenser fit?
The instrument is supplied with S40, GL32, GL38, GL25 and GL28 adapters. For a different bottle neck, the suitable adapter is determined before ordering.
From the same category

SafeVac, EcoVac and SmartVac Vacuum Aspirator
Vacuum aspirators with 4 L, 2 L and 1 L bottles that safely collect cell culture and plate washing waste.

Levo Pipette Controller and Pipette Pump
Motorized Levo controllers working with 0.1–100 mL serological pipettes and the manual Levo E pipette pump.

HiPette Single-Channel Mechanical Pipette
Fully autoclavable single-channel mechanical pipette family offering adjustable volume options from 0.1 µL to 10 mL.

HiPette Multichannel Mechanical Pipette
Color-coded, fully autoclavable 8-, 12- and 16-channel mechanical pipettes for 96- and 384-well plates.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote