DLAB
StepMate Repeater Pipette (Stepper)
DLAB StepMate is a repeater pipette (stepper) that dispenses liquid aspirated once in consecutive equal doses. It works with seven different dispenser tips from 0.5 mL to 50 mL and offers step volumes from 10 µL to 5 mL.
Request a quote| Step volume | 10 µL–5 mL (depending on tip) |
|---|---|
| Dispenser tips | 0.5 mL–50 mL, 7 sizes |
| Consecutive steps | Up to 48 |
| Systematic error | ±0.2%–±0.8% (depending on tip) |
| Random error | ≤0.2%–≤0.7% (depending on tip) |
Product description
A repeater pipette is used for tasks in which the same liquid is dispensed in equal volumes into many vessels. The user aspirates liquid into the dispenser tip once, then each press of the button delivers the set step volume. This eliminates a separate aspiration for each well, shortening the process and reducing repetitive movement.
DLAB StepMate is operated with one hand thanks to its slim, lightweight body. A durable tip-holding lever secures single-use polypropylene dispenser tips from 0.5 mL to 50 mL. The tip volume and the selected step together determine the total number of steps; up to 48 consecutive steps can be dispensed from a single aspiration.
Model comparison
StepMate is a single body; the step volume and accuracy vary with the dispenser tip fitted. The published values are below.
| Dispenser tip | Step volume options | Systematic error | Random error |
|---|---|---|---|
| 0.50 mL | 10 · 20 · 30 · 40 · 50 µL | ±0.8% | ≤0.7% |
| 1.25 mL | 25 · 50 · 75 · 100 · 125 µL | ±0.8% | ≤0.5% |
| 2.50 mL | 50 · 100 · 150 · 200 · 250 µL | ±0.8% | ≤0.4% |
| 5.00 mL | 100 · 200 · 300 · 400 · 500 µL | ±0.4% | ≤0.3% |
| 12.50 mL | 250 · 500 · 750 · 1000 · 1250 µL | ±0.3% | ≤0.3% |
| 25.00 mL | 500 · 1000 · 1500 · 2000 · 2500 µL | ±0.2% | ≤0.3% |
| 50.00 mL | 1000 · 2000 · 3000 · 4000 · 5000 µL | ±0.2% | ≤0.2% |
Applications
- Bulk reagent loading into 96- and 384-well plates
- Dispensing master mix in PCR and qPCR setup
- ELISA, cell and microbial culture work
- Dispensing standard solutions and buffers
- Repetitive dosing of viscous, dense or volatile liquids
As the dispenser tip works on the positive displacement principle, there is no air cushion. Consistent dispensing is therefore achieved even with viscous, dense or high-vapor-pressure liquids.
Selection criteria for repeater pipettes
- Step volume: The dose to be dispensed determines the tip choice; 0.5 mL or 1.25 mL tips are used for small doses.
- Total volume: The more wells to be filled from one aspiration, the larger the tip that is preferred.
- Liquid type: With viscous and volatile liquids, a repeater pipette gives more consistent results than an air-displacement pipette.
- Tip stock: Dispenser tips are single-use; stock is planned according to consumption.
If an electronic solution is preferred, the multi-dispensing mode of the dPette+ electronic pipette performs a similar task with a motor. For dispensing reagents directly from the bottle, bottle-top dispensers are suitable. All options are among the liquid handling products; general information on methods is on the technologies page.
Technical specifications
| Dispensing principle | Positive displacement, single-use dispenser tip |
|---|---|
| Dispenser tip volumes | 0.5 · 1.25 · 2.5 · 5 · 12.5 · 25 · 50 mL |
| Step volume range | 10 µL–5 mL (depending on tip) |
| Consecutive steps | Up to 48 from a single aspiration |
| Systematic error | ±0.2%–±0.8% (depending on tip) |
| Random error | ≤0.2%–≤0.7% (depending on tip) |
| Tip material | Polypropylene |
| Tip holding | Durable tip-holding lever |
| Body | Slim, lightweight and robust |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
What is the difference between a repeater pipette and an electronic pipette?
A repeater pipette uses a positive-displacement dispenser tip and operates mechanically. An electronic pipette operates with a motor and an air-displacement tip. With viscous and volatile liquids, a repeater pipette gives more consistent results.
How many steps can be dispensed from one aspiration?
The number of steps depends on the tip volume and the selected step volume, and reaches up to 48 steps from a single aspiration.
Can dispenser tips be reused?
The tips are single-use polypropylene tips. To prevent the risk of contamination, a new tip is recommended for each liquid or sample.
From the same category

SafeVac, EcoVac and SmartVac Vacuum Aspirator
Vacuum aspirators with 4 L, 2 L and 1 L bottles that safely collect cell culture and plate washing waste.

Levo Pipette Controller and Pipette Pump
Motorized Levo controllers working with 0.1–100 mL serological pipettes and the manual Levo E pipette pump.

DispensMate Bottle-Top Dispenser
DispensMate dispensers mounted on the reagent bottle, adjustable from 0.5 to 100 mL; HF model for hydrofluoric acid.

HiPette Single-Channel Mechanical Pipette
Fully autoclavable single-channel mechanical pipette family offering adjustable volume options from 0.1 µL to 10 mL.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote