DUKO LifeDUKO Life
DLAB HiPette autoclavable single-channel mechanical pipette

DLAB

HiPette Single-Channel Mechanical Pipette

HiPette is a fully autoclavable mechanical pipette family offering single-channel adjustable volume options between 0.1 µL and 10 mL. The family includes the standard HiPette, the color-coded HiPette Colorful and the HiPette-LTS models working with LTS tips.

Request a quote
Channels1 (single-channel)
Volume range0.1 µL to 10 mL (depending on model)
SterilizationFully autoclavable
Plunger force1st stop 4 N, 2nd stop 10 N
SeriesHiPette, HiPette Colorful, HiPette-LTS

Product description

HiPette is a fully autoclavable mechanical pipette family designed for everyday liquid transfer. Because the entire pipette can be sterilized at high temperature and pressure, no separate preparation step is needed in areas requiring sterile work, such as cell culture and microbiology.

The models in the family share the same body design but differ in how they are used. The standard HiPette covers the basic need with a wide volume range. The HiPette Colorful marks volume ranges with a color scale, reducing the likelihood of selecting the wrong pipette in busy laboratories. The HiPette-LTS is designed to work with thin-walled LTS tips and provides a lighter touch for users who pipette frequently.

According to manufacturer data, the first stop operates with a force of 4 N and the second stop with 10 N. This low force limits hand and wrist fatigue during prolonged serial pipetting.

Model comparison

ModelChannelsVolume rangesDistinguishing feature
HiPette10.1–2.5 µL · 0.5–10 µL · 2–20 µL · 5–50 µL · 10–100 µL · 20–200 µL · 30–300 µL · 100–1,000 µL · 1,000–5,000 µL · 500–5,000 µL · 2,000–10,000 µL · 1,000–10,000 µLWide volume range, volume lock
HiPette Colorful10.1–2.5 µL · 0.5–10 µL · 2–20 µL · 5–50 µL · 10–100 µL · 20–200 µL · 30–300 µL · 100–1,000 µL · 500–5,000 µL · 1,000–10,000 µLColor-coded body by volume range
HiPette-LTS10.1–2.5 µL · 0.5–10 µL · 2–20 µL · 5–50 µL · 10–100 µL · 20–200 µL · 30–300 µL · 100–1,000 µLLTS tip system, light plunger feel

The table below shows the accuracy values published by the manufacturer for the HiPette volume ranges at the largest test volume.

Volume rangeIncrementSystematic error (at largest volume)Random error (at largest volume)
0.1–2.5 µL0.002 µL±0.04 µL ±1.4%±0.02 µL ±0.7%
0.5–10 µL0.01 µL±0.10 µL ±1.0%±0.04 µL ±0.4%
2–20 µL0.02 µL±0.20 µL ±1.0%±0.06 µL ±0.3%
5–50 µL0.05 µL±0.45 µL ±0.9%±0.15 µL ±0.3%
10–100 µL0.1 µL±0.80 µL ±0.8%±0.20 µL ±0.2%
20–200 µL0.2 µL±1.20 µL ±0.6%±0.40 µL ±0.2%
30–300 µL0.2 µL±1.80 µL ±0.6%±0.60 µL ±0.2%
100–1,000 µL1 µL±6.00 µL ±0.6%±2.00 µL ±0.2%
1,000–5,000 µL5 µL±30.00 µL ±0.6%±10 µL ±0.2%
500–5,000 µL5 µL±30.00 µL ±0.6%±10.00 µL ±0.2%
2,000–10,000 µL10 µL±60.00 µL ±0.6%±20.00 µL ±0.2%
1,000–10,000 µL10 µL±60.00 µL ±0.6%±20.00 µL ±0.2%

Applications

  • Standard and reagent preparation, sample dilution and routine liquid transfer
  • Cell culture and microbiology work requiring a sterile environment
  • Quick recognition of volume ranges with color-coded models in teaching laboratories
  • Analytical laboratories performing highly repetitive pipetting with LTS tips

For suitable tip selection, bulk pipette tips and, for protection against contamination, filter pipette tips are considered together.

Autoclavable mechanical pipette selection criteria

Selection is made first according to the volume range to be used. Since a pipette's accuracy usually reaches its best value in the upper part of the range, it is recommended that the frequently used volume should not be close to the lower limit of the selected model.

If many wells are dispensed into at the same time, multichannel HiPette models significantly reduce the workload. For repetitive dispensing and long series, electronic pipettes, and for routine fixed-volume tasks, mini pipettes are considered as alternatives. Other liquid handling products are found in the liquid handling category.

After autoclaving, the pipette should be left to cool and dry completely; gravimetric verification at one volume is then recommended as a daily check.

Technical specifications

Number of channels1
Volume range0.1 µL to 10 mL (depending on model)
Volume incrementOne-thousandth of the range (e.g. 0.002 µL on the 0.1–2.5 µL model)
First / second stop force4 N / 10 N
SterilizationFully autoclavable
Volume settingOne-touch volume lock
Color codingOn HiPette Colorful models
Tip systemLTS tips on HiPette-LTS models
Body weightUnder 100 g (HiPette Colorful)

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between the HiPette and the HiPette-LTS?

The HiPette-LTS is designed to work with thin-walled LTS tips. Attaching and ejecting tips requires less force; it is therefore preferred for frequent and prolonged pipetting.

Can the entire pipette be autoclaved?

Yes. The HiPette family is designed to be fully autoclavable. After autoclaving, the pipette should be allowed to cool and dry.

What is the advantage of the color-coded model?

On HiPette Colorful models, each volume range is marked with a different color. This prevents the wrong pipette from being selected on benches where several pipettes are used and simplifies the training of new staff.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.