The multi-position magnetic stirrer series enables several samples to be stirred simultaneously under the same conditions. The series includes seven options, from 4- and 6-channel models with individually heated positions to compact models that stir 10 or 15 samples on a single plate.

Request a quote
Number of positions4, 6, 10 or 15
HeatingNon-heating, 120 °C, 280 °C or 340 °C (depending on model)
Speed range0-1100 rpm or 200-1500 rpm
Capacity per position0.4 L, 3 L or 10 L water
DisplayLCD or analog scale

Product description

In parallel experiments, solubility tests and repeated sample preparation, placing each sample on a separate instrument strains both bench space and consistency of conditions. Multi-position magnetic stirrers solve this problem by processing samples on a single body with the same control logic.

The series consists of two groups. In the MS-H280-S4, MS-H280-S6 and MS-H340-S4 models, each position is a separate Ø134-135 mm plate and is heated; this design is suitable for parallel reactions with medium-volume beakers. The MS-M-S4 and MS-M-S6 offer the same plate design without heating. The MS-H-S10, MS-M-S10 and MS-T-S15 stir 10 or 15 small-volume samples of up to 0.4 L on a single plate.

All models use a brushless DC motor. This motor design reduces maintenance requirements in applications where many positions run for long periods.

Model comparison

ModelPositionsPlateHeatingSpeed rangeCapacity per positionDisplay
MS-H280-S44Ø134 mm, ceramic-coated25-280 °C200-1500 rpm3 LLCD
MS-H280-S66Ø134 mm, ceramic-coated25-280 °C200-1500 rpm3 LLCD
MS-H340-S44Ø135 mm, ceramic-coated25-340 °C200-1500 rpm10 LLCD
MS-M-S44Ø134 mm, ceramic-coatedNon-heating200-1500 rpm3 LLCD
MS-M-S66Ø134 mm, ceramic-coatedNon-heating200-1500 rpm3 LLCD
MS-H-S1010180x450 mm aluminumRoom temperature - 120 °C0-1100 rpm0.4 LAnalog scale
MS-M-S1010180x450 mm, silicone-coated stainless steelNon-heating0-1100 rpm0.4 LAnalog scale
MS-T-S1515460x304 mm aluminumNon-heating100-1500 rpm0.4 LLCD

On the 4- and 6-channel models, the speed and (on heated models) the temperature of each position are set independently. The heated 4- and 6-channel models support a PT1000 external temperature sensor and offer temperature control accuracy of ±1 °C below 100 °C. The MS-H280-S6 operates only on a 200-240 V supply.

Applications

  • Parallel testing of the same recipe under different conditions (synthesis screening)
  • Simultaneous sample preparation for solubility and stability tests
  • Simultaneous work by student groups in teaching laboratories
  • Serial preparation of small-volume buffers and standard solutions (10- and 15-position models)
  • Stirring of large numbers of culture media in microbiology and food laboratories

Multi-position magnetic stirrer selection criteria

The first selection criteria are sample volume and heating requirements. For volumes up to 3 L per beaker with heating, the MS-H280-S4 or S6 is suitable; for volumes up to 10 L and heating up to 340 °C, the MS-H340-S4. If no heating is required, the MS-M-S4 or MS-M-S6 is preferred.

If many samples are to be processed in small bottles and tubes, the 10-position MS-H-S10 (with heating up to 120 °C) or MS-M-S10 is selected, and the 15-position MS-T-S15 for the highest number of samples. The maximum stir bar length on these models is 40 mm.

When working with a single sample, the MS-H series hotplate stirrers or the non-heating MS, FlatSpin and EcoStir magnetic stirrers are more economical. Since one stir bar is required per position, planning together with a PTFE-coated magnetic stir bar set is recommended. Other options are listed under mixing and shaking products.

Technical specifications

Number of positions4, 6, 10 or 15 (depending on model)
PlateSeparate Ø134-135 mm plates (4- and 6-channel models); 180x450 mm or 460x304 mm common plate
Heating range25-280 °C, 25-340 °C, room temperature - 120 °C or non-heating
Temperature control accuracy±1 °C (<100 °C), ±1% (>100 °C) (heated 4- and 6-channel models)
External temperature sensorPT1000, ±0.2 °C (heated 4- and 6-channel models)
Speed range200-1500 rpm, 100-1500 rpm or 0-1100 rpm
Capacity per position (water)0.4 L, 3 L or 10 L
Maximum stir bar40 mm
MotorBrushless DC motor
Overheat protection420 °C (heated 4- and 6-channel models), 140 °C (MS-H-S10)
Protection classIP20 or IP21 (depending on model)
Power supply100-120 V / 200-240 V, 50/60 Hz (MS-H280-S6: 200-240 V, 50 Hz)
Weight3.2-12.7 kg (depending on model)

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Is each position heated separately on the 4- and 6-channel heated models?

Yes. On the MS-H280-S4, MS-H280-S6 and MS-H340-S4 models, start/stop, temperature and speed settings for each position are independent of one another. Different conditions can therefore be tested in parallel on the same instrument.

Which vessels are used with the 10- and 15-position models?

These models are designed for up to 0.4 L of water per position. Small beakers, bottles and vials are used with stir bars of up to 40 mm.

Are all samples stirred at the same speed?

On the MS-H-S10 and MS-M-S10 models, the 10 positions run with a single speed setting. On the MS-T-S15, the 15 positions are divided into three independent channels, and each channel can be run at a different speed and time. For homogeneous results, the same type of vessel, the same volume and the same size of stir bar are recommended.

When is a non-heating multi-position model sufficient?

For solubility tests, buffers stirred at room temperature and temperature-sensitive samples, the non-heating MS-M-S4, MS-M-S6, MS-M-S10 or MS-T-S15 is sufficient; these consume less energy than heated models.