DUKO LifeDUKO Life
DLAB OS-T Plus overhead stirrer with timer

DLAB

OS-T Plus Overhead Stirrer with Timer

The OS-T Plus overhead stirrer with timer is developed for applications where stirring time and sample temperature must be monitored together. The series consists of the OS-T40/OS-T60-Plus with 30 and 50 liter capacity and the two-speed-range OS-T400-Plus with 100 liter capacity.

Request a quote
Capacity (water)30 L, 50 L, 100 L
Max. torque40–400 N·cm
Timer1 min to 99 h 59 min
Temperature inputPT1000 (±0.2 °C)
Data interfaceRS485, Type-C, USB

Product description

The OS-T Plus series adds timing, temperature reading and data connectivity to the stirring platform of the OS series. An external PT1000 sensor connected to the instrument shows the sample temperature on the display with 0.1 °C resolution, so stirring and temperature monitoring are handled from the same panel.

The LCD display shows speed, torque, time and temperature together. A safety lock prevents settings from being changed accidentally during operation. The OS-T40 and OS-T60-Plus models support forward, reverse and intermittent stirring modes; this mode reduces build-up on the impeller in mixtures that form sediment.

Model comparison

ModelCapacity (water)Speed rangeMax. torqueMax. viscosityWeight
OS-T40-Plus30 L50–2,200 rpm40 N·cm10,000 mPa·s3.5 kg
OS-T60-Plus50 L50–2,200 rpm60 N·cm50,000 mPa·s3.5 kg
OS-T400-Plus100 LA: 10–400 rpm · B: 50–2,000 rpm400 N·cm150,000 mPa·s5.2 kg

The two-range speed design of the OS-T400-Plus allows thick mixtures requiring high torque at low speed and high-speed dispersing work to be handled with the same instrument.

Applications

  • Temperature-monitored synthesis and polymerization reactions
  • Dissolution and mixing steps that must be completed within a defined time
  • Pre-production trials of cosmetic creams, gels and emulsions
  • Liquid mixtures up to 100 liters at pilot scale

Correct use and logging

The temperature sensor is immersed in the sample so that it does not touch the impeller; leaving a distance between the sensor tip and the impeller keeps the measurement stable. In long stirring runs, the timer ends the process automatically after the required time and reduces operator-dependent variation.

USB, Type-C and RS485 connections allow speed, torque and temperature data to be recorded. These records serve as a reference when transferring laboratory conditions unchanged to pilot trials during scale-up. While the safety lock is active, settings do not change, so pressing a wrong key during operation does not affect the result.

The brushless DC motor on the OS-T40 and OS-T60-Plus models runs maintenance-free for long periods. The through-shaft design allows the vessel to be changed while the stirring element stays in place, which saves time in trials where the same recipe is repeated in different vessels. In addition, constant speed control maintains stirring conditions even if the sample viscosity changes during the reaction.

Overhead stirrer with timer selection criteria

Selection is based on sample volume, viscosity and logging requirements. For water-like samples up to 30 L, the OS-T40-Plus is sufficient; for mixtures around 50,000 mPa·s, the OS-T60-Plus should be considered, and for thicker mixtures or volumes approaching 100 L, the OS-T400-Plus.

If temperature reading and a timer are not needed, the OS series overhead stirrer is a simpler and more economical option. If heating is also required, the mixture can be processed on a hotplate stirrer or in a bath. Other options are in the mixing and shaking category.

Technical specifications

Capacity (water)30–100 L depending on model
Speed range50–2,200 rpm · OS-T400-Plus: 10–400 / 50–2,000 rpm
Timer1 min to 99 h 59 min
Max. torque40–400 N·cm depending on model
Max. viscosity10,000–150,000 mPa·s depending on model
Rotation modeForward, reverse, intermittent (OS-T40/T60-Plus)
Temperature sensorExternal PT1000, ±0.2 °C accuracy
Temperature display resolution0.1 °C
DisplayLCD: speed, torque, time, temperature
Data interfaceRS485, Type-C, USB
Chuck diameter2–10 mm
Power70–300 W depending on model
Power supply100–240 V, 50/60 Hz
Weight3.5–5.2 kg

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Does the temperature sensor heat the sample?

No. The PT1000 sensor only measures the sample temperature and shows it on the display; heating requires a separate hot plate or bath.

What is intermittent stirring for?

Stirring that changes direction or continues with pauses reduces the accumulation of solid particles around the impeller and helps the mixture disperse more homogeneously.

Why does the OS-T400-Plus have two speed ranges?

Range A provides high torque at 10–400 rpm and is intended for thick mixtures; range B offers fast stirring at 50–2,000 rpm for lower-viscosity work.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote