DLAB
DEP Series Electrophoresis Power Supply
The DEP series electrophoresis power supply operates in constant voltage, constant current and constant power modes for gel electrophoresis and blotting applications, and switches between modes automatically. In addition to the standard 300 V and 600 V models, the series includes the high-current DEP-300HC and the DEP-600HC, which will be available soon.
Request a quote| Voltage range | 0–300 V (DEP-300), 0–600 V (DEP-600) |
|---|---|
| Current range | 0–600 mA; 2500–3000 mA on HC models |
| Power range | 150–500 W (depending on model) |
| Operating mode | Constant voltage, current or power |
| Outputs | 4 sets, 4 tanks simultaneously |
Product description
An electrophoresis power supply is an instrument that drives the movement of molecules in the gel by supplying controlled direct current to the electrodes in the tank. Reproducible separation depends on keeping voltage or current constant throughout the run. The DEP series offers these three parameters continuously adjustable from zero and automatically switches to another mode when the limit of the selected mode is reached.
The instruments are programmed via a 4.3-inch touchscreen LCD, and up to 20 multi-step programs can be stored. Run parameters can be recorded via USB. After a power failure, settings are restored according to the needs of the experiment; a low-current protection function prevents bands from diffusing or samples from running out of the gel after electrophoresis has finished.
Model comparison
| Model | Voltage | Current | Power | Typical use |
|---|---|---|---|---|
| DEP-300 | 0–300 V | 0–600 mA | 0–150 W | Agarose and mini vertical gels |
| DEP-300HC | 0–300 V | 0–3000 mA | 0–400 W | High-current wet transfer |
| DEP-600 | 0–600 V | 0–600 mA | 0–360 W | Vertical and high-throughput electrophoresis and blotting |
| DEP-600HC (coming soon) | 0–600 V | 0–2500 mA | 0–500 W | Applications requiring high voltage and high current |
On all models, the resolution is 1 V for voltage, 1 mA for current and 1 W for power. The timer can be set from 1 minute to 99 hours 59 minutes, and all four output sockets can be used at the same time.
Applications
- SDS-PAGE and Native-PAGE protein electrophoresis
- DNA and RNA electrophoresis in agarose gels
- Wet transfer for Western blotting (high-current models)
- Teaching and research laboratories in which several tanks are run at the same time
The power supply is used with DL-Mini vertical tanks, DL-SUB horizontal tanks and DL-ZY transfer tanks.
Correct use
The power supply should not be operated before the tank connections are made and the lid is closed. Before starting a program, the voltage, current and time limits are checked for suitability for the gel type; if more than one tank is connected, it is verified that the total current does not exceed the instrument limit. Non-slip recesses that allow the instruments to be stacked save bench space; however, the ventilation openings must not be covered. At the end of the run, the program is stopped first and then the connecting leads are removed.
Electrophoresis power supply selection criteria
- Voltage requirement: 300 V is sufficient for agarose gels and mini vertical gels; for larger vertical gels and high-throughput separations, the 600 V models are preferred.
- Transfer: Wet transfer draws high current; the DEP-300HC is suitable for laboratories performing Western blots regularly.
- Simultaneous operation: The four output sockets can power four tanks at the same time; however, the total current and power limit is shared by all tanks.
- Recording requirements: Parameter logging via USB provides traceability in laboratories that must report experimental conditions.
The instrument has no-load, overtemperature, overvoltage, overcurrent, load change and ground leakage protection; no-load detection can be disabled for low-current applications. All electrophoresis products are listed in the electrophoresis category.
Technical specifications
| Display | 4.3-inch touchscreen LCD |
|---|---|
| Output type | Constant voltage, constant current, constant power (continuously adjustable, automatic crossover) |
| Voltage range | 0–300 V (DEP-300, 300HC); 0–600 V (DEP-600, 600HC) |
| Current range | 0–600 mA (DEP-300, 600); 0–3000 mA (DEP-300HC); 0–2500 mA (DEP-600HC) |
| Power range | 0–150 W (DEP-300); 0–360 W (DEP-600); 0–400 W (DEP-300HC); 0–500 W (DEP-600HC) |
| Resolution | 1 V, 1 mA, 1 W |
| Timer | 1 minute to 99 hours 59 minutes |
| Programs | Up to 20 multi-step programs |
| Interface | USB |
| Output sockets | 4 sets |
| Protection | No-load, overtemperature, overvoltage, overcurrent, load change, ground leakage |
| Operating environment | 0–40 °C, max. 95% relative humidity |
| Dimensions | 310 × 260 × 115 mm |
| Weight | 1.90–2.05 kg (depending on model) |
| Certification | CE, UKCA, FCC, ICES; CB and cTUVus |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
Should constant voltage or constant current be used?
Constant voltage is generally preferred for agarose and SDS-PAGE gels, as the separation time is more predictable. For wet transfer, constant current is mostly used to limit heating.
Can four tanks be run with different programs at the same time?
The four output sockets can be used at the same time, but the same output value is applied to all of them. Separate power supplies are recommended for tanks requiring different conditions.
When are the HC models needed?
Because the HC models can deliver high current, they are used for wet transfer and large-volume tanks. In laboratories performing only gel electrophoresis, the standard models are sufficient.
From the same category

DL-Mini Vertical Electrophoresis Tank
Mini-format vertical electrophoresis tanks for separating protein and nucleic acid samples in polyacrylamide gels.

DL-ZY Transfer (Blotting) Electrophoresis Tank
Wet transfer tanks with platinum electrodes that transfer proteins from polyacrylamide gels to membranes.

DL-SUB Horizontal Electrophoresis Tank
Horizontal electrophoresis tanks with platinum electrodes, working with agarose gels for DNA separation and molecular weight determination.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote