DUKO LifeDUKO Life
DLAB DL-Mini vertical electrophoresis tank and gel cassettes

DLAB

DL-Mini Vertical Electrophoresis Tank

The DL-Mini vertical electrophoresis tank is a mini-format system designed for separating protein and small-volume nucleic acid samples in polyacrylamide gels. The DL-Mini01 runs two 8.3 × 7.3 cm gels and the DL-Mini04 runs 1–4 gels at the same time; gel thickness can be selected as 0.75, 1.0 or 1.5 mm.

Request a quote
ApplicationSDS-PAGE, Native-PAGE, small nucleic acid gels
Gel size8.3 × 7.3 cm
Number of gels2 (DL-Mini01), 1–4 (DL-Mini04)
Gel thickness0.75 · 1.0 · 1.5 mm
Comb10 or 15 wells

Product description

A vertical electrophoresis tank is a system in which a polyacrylamide gel cast between two glass plates is placed upright in buffer solution and samples are separated by size in an electric field. The most common application in protein analysis is SDS-PAGE; the same setup is also used for native protein gels and small nucleic acid fragments.

In the DL-Mini series, the glass plate and gasket are either integrated or permanently fixed to the long plate; this design prevents leakage during gel casting. The electrodes are made of 99.99% pure platinum wire. The lid cannot be fitted in the wrong orientation, and the electrical connection is cut when it is opened; this feature reduces electrical risk during operation.

Model comparison

ModelGel capacityGel thicknessCombCompatible transfer tank
DL-Mini012 gels, 8.3 × 7.3 cm0.75 · 1.0 · 1.5 mm10 or 15 wellsDL-ZY02
DL-Mini041–4 gels0.75 · 1.0 · 1.5 mm10 or 15 wellsDL-ZY03

On the DL-Mini04, the cam-lock gel frame aligns the glass plates in a single motion, and the one-piece casting stand allows two gels to be prepared at the same time. The manufacturer specifies an SDS-PAGE run time of 45 minutes at a constant 200 V for this model.

Applications

  • Protein purity checks and molecular weight estimation (SDS-PAGE)
  • Protein separation prior to Western blotting
  • Investigation of protein complexes under native conditions (Native-PAGE)
  • High-resolution separation of small DNA and RNA fragments
  • Molecular biology exercises in teaching laboratories

After the gel is run, it must be gently agitated during staining and destaining; SK-O orbital shakers are used for this task.

Correct use

Clean, grease-free glass plates before casting ensure that polymerization proceeds evenly and that the gel adheres well to the plate. Overlaying the top surface with water or isopropanol after pouring the resolving gel creates a straight boundary. The buffer solution should be freshly prepared for each run, and the inner and outer chambers filled to the manufacturer's marks. After the run, the tank is rinsed with pure water and left to dry; not leaving the gaskets in buffer for long periods extends their service life.

Vertical electrophoresis tank selection criteria

  • Daily number of gels: If two gels per run are sufficient, the DL-Mini01 is preferred; if up to four gels are needed, the DL-Mini04 is preferred.
  • Western blot plans: If transfer to a membrane will follow separation, the compatible DL-ZY transfer tank is selected together with the tank.
  • Power supply: Vertical systems are usually run at constant voltage; four-output DEP series power supplies can power multiple tanks at the same time.
  • Gel thickness: Thin gels give sharper bands, while thick gels allow more sample to be loaded; the plate and comb set is determined accordingly.

For separating nucleic acids in agarose gels, horizontal electrophoresis tanks are more suitable. All systems are listed in the electrophoresis category.

Technical specifications

Gel size8.3 × 7.3 cm
Number of gelsDL-Mini01: 2 · DL-Mini04: 1–4
Gel thickness0.75 mm, 1.0 mm, 1.5 mm (optional)
Comb options10 or 15 wells
Electrode99.99% pure platinum
SealingIntegrated glass plate and gasket (DL-Mini01), edge gasket fixed to the plate (DL-Mini04)
SafetyPower is cut when the lid is opened; keyed to prevent incorrect orientation
SDS-PAGE run time45 minutes at a constant 200 V (DL-Mini04, manufacturer data)
Compatible transfer tankDL-ZY02 (DL-Mini01), DL-ZY03 (DL-Mini04)

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the main difference between the DL-Mini01 and DL-Mini04?

The DL-Mini01 is a dual-plate tank that runs two gels at the same time. The DL-Mini04, with its cam-lock frame, offers flexible use with 1–4 gels and simplifies plate alignment.

Can these tanks be used for DNA electrophoresis?

Small nucleic acid fragments can be separated in polyacrylamide gels in a vertical system. For routine DNA checks and large fragments, however, horizontal tanks working with agarose gels are more practical.

Which power supply should be used?

For vertical gels, a power supply capable of delivering a constant voltage of 300 V or more is sufficient. The DEP-300 and DEP-600 models, with their four outputs, can power several tanks at the same time.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote