DL-SUB Horizontal Electrophoresis Tank

The DL-SUB horizontal electrophoresis tank is a system used for the rapid separation, identification and sizing of DNA and RNA fragments in agarose gels. The series includes four models, from the compact DL-SUB01 with a 60 × 75 mm gel to the DL-SUB03+ with a 130 × 200 mm gel and built-in blue light.

Request a quote
ApplicationDNA and RNA separation in agarose gels
Gel sizeFrom 60 × 75 mm to 130 × 200 mm
Buffer volume300 mL (SUB01), 800 mL (SUB03)
Electrode99.99% platinum, removable
VisualizationBlue light transillumination system (DL-SUB03+)

Product description

In a horizontal electrophoresis tank, the agarose gel lies horizontally in a tray beneath the buffer solution. Samples are loaded into the wells of the gel, and in the electric field the negatively charged nucleic acids migrate toward the positive electrode at different speeds according to their size. PCR product checks, restriction enzyme digestion and plasmid analysis are the most common tasks for this method.

In the DL-SUB series, the tank body is made of one-piece injection-molded transparent polycarbonate; this design prevents leakage. The electrodes are 99.99% pure platinum and can be removed for maintenance. A polarity limiter prevents the lid from being fitted the wrong way round. On the larger models, an adjustment knob on the base keeps the tank level; a background strip on the tray makes sample loading easier.

Model comparison

ModelGel size (W × L)CombBuffer volumeKey feature
DL-SUB0160 × 75 mm1.0 / 1.5 mm, 6 or 11 wells300 mLCompact design, vented lid that prevents fogging
DL-SUB02120 × 120, 120 × 60, 60 × 120, 60 × 60 mmUp to 4 rows of combs on the large gelNot specifiedFour gel sizes, tray with fluorescent ruler
DL-SUB03130 × 200 mm, 130 × 150 mm1.0 mm 14, 18, 26 wells; 1.5 mm 18 wells800 mLHigh-throughput use, lid with blue light shield
DL-SUB03+130 × 200 mm, 130 × 150 mmOptionalNot specifiedBuilt-in blue light, up to 200 samples per run

The matrix-type blue light transillumination system on the DL-SUB03+ allows bands to be monitored while electrophoresis is running when working with safe DNA stains excited by blue light. The blue light switches off automatically after 5 minutes to protect LED life.

Applications

  • Size and purity checks of PCR products
  • Plasmid and genomic DNA analysis
  • Examination of restriction enzyme digestion products
  • DNA fragment preparation prior to cloning
  • Genotyping studies in which many samples are screened on a single gel (DL-SUB03, DL-SUB03+)

Products checked on agarose gels are mostly prepared in TC series PCR thermal cyclers. Using an orbital shaker during gel staining and destaining shortens the time and gives uniform results.

Horizontal agarose gel electrophoresis tank selection criteria

  • Number of samples: The DL-SUB01 suits a small number of PCR checks, the DL-SUB02 flexible work with different gel sizes, and the DL-SUB03 or DL-SUB03+ high sample numbers.
  • Visualization: If bands are to be monitored during the run, the DL-SUB03+ with built-in blue light reduces the need for a separate imaging step.
  • Buffer consumption: A small tank uses less buffer; operating costs fall for frequent, small-scale runs.
  • Power supply: Agarose gels are usually run at 100–150 V; DEP series power supplies can power four tanks at the same time.

For protein separation, DL-Mini vertical electrophoresis tanks are preferred. All systems are listed in the electrophoresis category.

Technical specifications

ApplicationNucleic acid separation, identification and molecular weight determination in agarose gels
Gel sizeDL-SUB01: 60 × 75 mm · DL-SUB02: 120 × 120, 120 × 60, 60 × 120, 60 × 60 mm · DL-SUB03 and 03+: 130 × 200, 130 × 150 mm
CombDL-SUB01: 1.0/1.5 mm, 6/11 wells · DL-SUB03: 1.0 mm 14/18/26 wells, 1.5 mm 18 wells
Buffer volumeDL-SUB01: 300 mL · DL-SUB03: 800 mL
Electrode99.99% pure platinum, removable
BodyTransparent polycarbonate, injection-molded
SafetyPolarity limiter (prevents reversed fitting)
Blue lightDL-SUB03+: built-in matrix-type blue light, automatic switch-off after 5 minutes
Sample capacityDL-SUB03+: up to 200 samples per run

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Which stains are used with the blue light model?

The blue light system on the DL-SUB03+ is designed for use with safe nucleic acid stains excited by blue light. Stains excited by UV require a separate UV imaging system.

How is the gel size selected?

Gel size is selected according to the number of samples and the required separation distance. A long gel separates fragments of similar size better, while a wide gel allows more samples to be loaded per run.

How are the electrodes maintained?

The platinum electrodes are removable. Rinsing them with pure water and drying them after each use prevents buffer residue and salt buildup; a damaged electrode can be replaced separately.