DLAB MicroPette Plus autoclavable adjustable-volume pipette

DLAB

MicroPette Plus Fixed and Adjustable Volume Pipette

The MicroPette Plus fixed and adjustable volume pipette family can be autoclaved at 121 °C and 1 atm without any preparation. Single-channel adjustable models cover 0.1 µL to 20 mL, and fixed-volume models offer 12 volume options from 5 µL to 5000 µL.

Request a quote
Adjustable volume0.1 µL–20 mL
Fixed volume5 µL–5000 µL, 12 options
Autoclave121 °C, 1 atm, no preparation
UV resistanceYes
Volume settingRotary counter and digital display

Product description

MicroPette Plus is a mechanical pipette family that offers both adjustable and fixed-volume models in the same design. The pipette can be autoclaved at 121 °C and 1 atm pressure without disassembly or pretreatment, and is also suitable for UV disinfection.

On the adjustable models, the rotary counter and digital display allow fast and accurate volume setting. Fixed-volume models eliminate the risk of setting errors in routine work where a single volume is repeated continuously. A quick tip ejector and material resistant to harsh chemicals make daily use easier.

The family also includes fully autoclavable 8- and 12-channel models with enhanced UV resistance. These models bring the same material approach as the single-channel series to the multichannel format.

Model comparison

ModelChannelsVolume options
MicroPette Plus adjustable volume10.1–2.5 µL · 0.5–10 µL · 2–20 µL · 5–50 µL · 10–100 µL · 20–200 µL · 50–200 µL · 100–1000 µL · 200–1000 µL · 1000–5000 µL · 500–5000 µL · 1000–10000 µL · 2000–20000 µL
MicroPette Plus fixed volume15 µL · 10 µL · 20 µL · 25 µL · 50 µL · 100 µL · 200 µL · 250 µL · 500 µL · 1000 µL · 2000 µL · 5000 µL
MicroPette Plus UV-resistant8 and 1220–200 µL (8-channel) · 30–300 µL (8-channel) · 20–200 µL (12-channel) · 30–300 µL (12-channel)

The accuracy values published by the manufacturer for the adjustable-volume MicroPette Plus at the maximum test volume are as follows.

Volume rangeIncrementSystematic error (at maximum volume)Random error (at maximum volume)
0.1–2.5 µL0.05 µL±0.0625 µL ±2.5%±0.05 µL ±2.00%
0.5–10 µL0.1 µL±0.1 µL ±1.00%±0.08 µL ±0.80%
2–20 µL0.5 µL±0.18 µL±0.08 µL
5–50 µL0.5 µL±0.3 µL ±0.60%±0.15 µL ±0.30%
10–100 µL1 µL±0.80 µL ±0.80%±0.15 µL ±0.15%
20–200 µL1 µL±1.20 µL ±0.60%±0.30 µL ±0.15%
50–200 µL1 µL±1.20 µL ±0.60%±0.30 µL ±0.15%
100–1000 µL5 µL±6.00 µL ±0.60%±2.00 µL ±0.20%
200–1000 µL5 µL±6.00 µL ±0.60%±2.00 µL ±0.20%
1000–5000 µL50 µL±25.00 µL ±0.50%±7.50 µL ±0.15%
500–5000 µL50 µL±25.00 µL ±0.50%±7.50 µL ±0.15%
1000–10000 µL100 µL±60.00 µL ±0.60%±20.00 µL ±0.20%
2000–20000 µL100 µL±120.00 µL ±0.60%60.00 µL ±0.30%

Applications

  • Routine tests in which the same volume is repeated continuously (fixed-volume models)
  • Microbiology and cell culture work requiring frequent sterilization
  • Analytical laboratories working with harsh chemicals
  • PCR setup areas where UV disinfection is routine

Selection criteria for fixed and adjustable volume pipettes

If a single volume is repeated throughout the day, a fixed-volume model eliminates the risk of setting errors. If different volumes are used, an adjustable model is more flexible. In laboratories with frequent autoclaving, the maintenance steps recommended by the manufacturer should also be included in the schedule.

All 8- and 12-channel adjustable models are on the MicroPette Plus multichannel pipette page. For a color-coded alternative, the HiPette series can be considered. For sterile work, filter pipette tips are recommended; all options are in the liquid handling category.

The manufacturer recommends a 12-hour cooling and drying period after autoclaving, and lubrication of the piston and seals every 10 autoclave cycles.

Technical specifications

Adjustable volume range0.1 µL–20 mL (single-channel)
Fixed volume options5, 10, 20, 25, 50, 100, 200, 250, 500, 1000, 2000 and 5000 µL
UV-resistant models8 and 12 channels, 20–200 µL and 30–300 µL
Autoclave121 °C, 1 atm, no preparation required
After autoclaving12 hours of cooling and drying
MaintenancePiston and seal lubrication every 10 autoclave cycles
Volume settingRotary counter, digital display
Tip ejectionQuick tip ejector
Chemical resistanceMaterial resistant to harsh chemicals

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

When is a fixed-volume pipette preferred?

A fixed-volume pipette is preferred for routine tests in which the same volume is repeated throughout the day. As there is no setting step, the risk of working with the wrong volume is eliminated.

Should the pipette be disassembled before autoclaving?

No. MicroPette Plus can be autoclaved at 121 °C and 1 atm without any preparation. A cooling and drying period of approximately 12 hours is recommended after autoclaving.

What does the UV-resistant model provide?

UV-resistant models are designed to withstand material degradation over time in areas with routine UV disinfection, such as PCR workstations.