DLAB
MicroPette Plus Fixed and Adjustable Volume Pipette
The MicroPette Plus fixed and adjustable volume pipette family can be autoclaved at 121 °C and 1 atm without any preparation. Single-channel adjustable models cover 0.1 µL to 20 mL, and fixed-volume models offer 12 volume options from 5 µL to 5000 µL.
Request a quote| Adjustable volume | 0.1 µL–20 mL |
|---|---|
| Fixed volume | 5 µL–5000 µL, 12 options |
| Autoclave | 121 °C, 1 atm, no preparation |
| UV resistance | Yes |
| Volume setting | Rotary counter and digital display |
Product description
MicroPette Plus is a mechanical pipette family that offers both adjustable and fixed-volume models in the same design. The pipette can be autoclaved at 121 °C and 1 atm pressure without disassembly or pretreatment, and is also suitable for UV disinfection.
On the adjustable models, the rotary counter and digital display allow fast and accurate volume setting. Fixed-volume models eliminate the risk of setting errors in routine work where a single volume is repeated continuously. A quick tip ejector and material resistant to harsh chemicals make daily use easier.
The family also includes fully autoclavable 8- and 12-channel models with enhanced UV resistance. These models bring the same material approach as the single-channel series to the multichannel format.
Model comparison
| Model | Channels | Volume options |
|---|---|---|
| MicroPette Plus adjustable volume | 1 | 0.1–2.5 µL · 0.5–10 µL · 2–20 µL · 5–50 µL · 10–100 µL · 20–200 µL · 50–200 µL · 100–1000 µL · 200–1000 µL · 1000–5000 µL · 500–5000 µL · 1000–10000 µL · 2000–20000 µL |
| MicroPette Plus fixed volume | 1 | 5 µL · 10 µL · 20 µL · 25 µL · 50 µL · 100 µL · 200 µL · 250 µL · 500 µL · 1000 µL · 2000 µL · 5000 µL |
| MicroPette Plus UV-resistant | 8 and 12 | 20–200 µL (8-channel) · 30–300 µL (8-channel) · 20–200 µL (12-channel) · 30–300 µL (12-channel) |
The accuracy values published by the manufacturer for the adjustable-volume MicroPette Plus at the maximum test volume are as follows.
| Volume range | Increment | Systematic error (at maximum volume) | Random error (at maximum volume) |
|---|---|---|---|
| 0.1–2.5 µL | 0.05 µL | ±0.0625 µL ±2.5% | ±0.05 µL ±2.00% |
| 0.5–10 µL | 0.1 µL | ±0.1 µL ±1.00% | ±0.08 µL ±0.80% |
| 2–20 µL | 0.5 µL | ±0.18 µL | ±0.08 µL |
| 5–50 µL | 0.5 µL | ±0.3 µL ±0.60% | ±0.15 µL ±0.30% |
| 10–100 µL | 1 µL | ±0.80 µL ±0.80% | ±0.15 µL ±0.15% |
| 20–200 µL | 1 µL | ±1.20 µL ±0.60% | ±0.30 µL ±0.15% |
| 50–200 µL | 1 µL | ±1.20 µL ±0.60% | ±0.30 µL ±0.15% |
| 100–1000 µL | 5 µL | ±6.00 µL ±0.60% | ±2.00 µL ±0.20% |
| 200–1000 µL | 5 µL | ±6.00 µL ±0.60% | ±2.00 µL ±0.20% |
| 1000–5000 µL | 50 µL | ±25.00 µL ±0.50% | ±7.50 µL ±0.15% |
| 500–5000 µL | 50 µL | ±25.00 µL ±0.50% | ±7.50 µL ±0.15% |
| 1000–10000 µL | 100 µL | ±60.00 µL ±0.60% | ±20.00 µL ±0.20% |
| 2000–20000 µL | 100 µL | ±120.00 µL ±0.60% | 60.00 µL ±0.30% |
Applications
- Routine tests in which the same volume is repeated continuously (fixed-volume models)
- Microbiology and cell culture work requiring frequent sterilization
- Analytical laboratories working with harsh chemicals
- PCR setup areas where UV disinfection is routine
Selection criteria for fixed and adjustable volume pipettes
If a single volume is repeated throughout the day, a fixed-volume model eliminates the risk of setting errors. If different volumes are used, an adjustable model is more flexible. In laboratories with frequent autoclaving, the maintenance steps recommended by the manufacturer should also be included in the schedule.
All 8- and 12-channel adjustable models are on the MicroPette Plus multichannel pipette page. For a color-coded alternative, the HiPette series can be considered. For sterile work, filter pipette tips are recommended; all options are in the liquid handling category.
The manufacturer recommends a 12-hour cooling and drying period after autoclaving, and lubrication of the piston and seals every 10 autoclave cycles.
Technical specifications
| Adjustable volume range | 0.1 µL–20 mL (single-channel) |
|---|---|
| Fixed volume options | 5, 10, 20, 25, 50, 100, 200, 250, 500, 1000, 2000 and 5000 µL |
| UV-resistant models | 8 and 12 channels, 20–200 µL and 30–300 µL |
| Autoclave | 121 °C, 1 atm, no preparation required |
| After autoclaving | 12 hours of cooling and drying |
| Maintenance | Piston and seal lubrication every 10 autoclave cycles |
| Volume setting | Rotary counter, digital display |
| Tip ejection | Quick tip ejector |
| Chemical resistance | Material resistant to harsh chemicals |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
When is a fixed-volume pipette preferred?
A fixed-volume pipette is preferred for routine tests in which the same volume is repeated throughout the day. As there is no setting step, the risk of working with the wrong volume is eliminated.
Should the pipette be disassembled before autoclaving?
No. MicroPette Plus can be autoclaved at 121 °C and 1 atm without any preparation. A cooling and drying period of approximately 12 hours is recommended after autoclaving.
What does the UV-resistant model provide?
UV-resistant models are designed to withstand material degradation over time in areas with routine UV disinfection, such as PCR workstations.
From the same category

SafeVac, EcoVac and SmartVac Vacuum Aspirator
Vacuum aspirators with 4 L, 2 L and 1 L bottles that safely collect cell culture and plate washing waste.

Levo Pipette Controller and Pipette Pump
Motorized Levo controllers working with 0.1–100 mL serological pipettes and the manual Levo E pipette pump.

DispensMate Bottle-Top Dispenser
DispensMate dispensers mounted on the reagent bottle, adjustable from 0.5 to 100 mL; HF model for hydrofluoric acid.

HiPette Single-Channel Mechanical Pipette
Fully autoclavable single-channel mechanical pipette family offering adjustable volume options from 0.1 µL to 10 mL.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote