expression CMS compact mass spectrometer

Advion Interchim Scientific

expression CMS

expression CMS is a compact mass spectrometer that fits on a benchtop. It offers a range of m/z 10–1200 in the expression S model and m/z 10–2000 in the L model; with ESI, APCI and ASAP ion source options, it switches between positive and negative ion mode within a single analysis.

Request a quote
Mass rangem/z 10–1200 (S) · m/z 10–2000 (L)
Ion sourceESI, APCI or APCI/ASAP
PolarityPositive/negative ion mode switching within a single analysis (50 ms)
Mass accuracy± 0.1 m/z units
Dimensions66 × 28 × 56 cm · 32 kg

Product description

Mass spectrometers are usually instruments located in a separate analytical unit and requiring expert users. The expression CMS, by contrast, with dimensions of 66 × 28 × 56 cm and a weight of 32 kg, is designed to be installed directly on the bench in the synthesis laboratory.

Being able to perform mass confirmation on the chemist's own bench shortens the synthesis cycle; instead of sending the sample to a central analytical unit and waiting, the reaction result is available within a short time.

The instrument can be connected to a purification system. When used together with puriFlash systems, fractions are collected by mass; compounds that are not visible by UV but have a known mass are not missed.

With the Plate Express interface, analysis can be performed directly from a TLC plate, and with the ASAP probe directly from solid and liquid samples.

Technical approach of the compact mass spectrometer

Ion sources

ESI, APCI and APCI/ASAP options are available. ESI is suitable for polar and ionizable compounds, APCI for less polar compounds. ASAP (atmospheric solids analysis probe) allows solid samples to be analyzed directly without a dissolution step.

Positive/negative ion mode switching

Switching between positive and negative ion mode takes 50 ms within a single analysis; this allows compounds of different structure in a mixture to be seen in a single run.

Software

Mass Express is used for instrument control and data acquisition, Data Express for data processing, and CheMS for workflow selection and automatic parameter optimization. The software is designed with users who are not mass spectrometry specialists in mind.

Installation requirements

  • Nitrogen supply: 60 psi, purity above 98%, consumption below 10 L/min
  • LC/MS-grade solvents
  • Power supply: 100–240 VAC, 47–63 Hz, 915 VA (including computer)
  • Ambient temperature: 21 °C ± 3 °C; ± 1 °C for best performance
  • Computer running Windows 10 or 11 with at least 8 GB of memory

Nitrogen quality and consumption are the main items of operating cost. The choice between a nitrogen generator and nitrogen cylinders is made by a cost analysis based on usage intensity.

Integration with purification and TLC

Connected to purification systems such as the puriFlash 5.020, puriFlash 5.050 and puriFlash 5.250, the expression CMS enables fractions to be collected by mass. When used with the Plate Express TLC-MS interface, the identity of TLC spots is confirmed directly. All models are listed in the mass spectrometry solutions section.

Technical assessment of the compact mass spectrometer

A mass spectrometer is an instrument that needs support after purchase. Service, spare parts and training terms are clearly stated in the quotation.

Selecting the ion source appropriate to the compound type is critical. When the sample type is provided, an ion source recommendation is presented together with the rationale.

Technical specifications

Mass rangeexpression S: m/z 10–1200 · expression L: m/z 10–2000
Ion sourceESI, APCI or APCI/ASAP
Ion modePositive and negative; switching within a single analysis
Ion mode switching time50 ms
Flow rangeESI 10 µL/min – 1 mL/min · APCI 10 µL/min – 2 mL/min
Scan speed10,000 m/z units/second
Sensitivity100:1 S/N with 10 pg reserpine in SIM mode (m/z 609.3)
Mass accuracy± 0.1 m/z units (over the full range)
Mass stability0.1 m/z units over 12 hours (at m/z 1200)
Dynamic range4.5 orders of magnitude (decades)
Nitrogen supply60 psi, 98%+ purity nitrogen, < 10 L/min
Power supply100–240 VAC, 47–63 Hz, 915 VA
Dimensions66 × 28 × 56 cm
Weight32 kg
SoftwareMass Express, Data Express, CheMS

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Should ESI or APCI be selected?

ESI is preferred for polar and ionizable compounds, APCI for less polar compounds. If solid samples need to be analyzed without a dissolution step, the ASAP probe is used.

What is the difference between expression S and expression L?

The difference is in the mass range: the S model measures in the range m/z 10–1200 and the L model in the range m/z 10–2000. The L model is chosen for work with larger molecules.

What infrastructure does the instrument require?

It requires a nitrogen supply of more than 98% purity at 60 psi, LC/MS-grade solvents, 100–240 VAC power and an ambient temperature of 21 °C ± 3 °C.