DUKO LifeDUKO Life
TLC-FlashReader TLC plate reader

Advion Interchim Scientific

TLC-FlashReader

The TLC-FlashReader is a TLC plate reader that images thin-layer chromatography (TLC) plates under white light and 254 nm and 366 nm UV. It archives plates and transfers the image directly to puriFlash systems as a method.

Request a quote
Plate sizeUp to 8.5 cm wide × 12.5 cm high
Light sourcesWhite light, UV 254 nm, UV 366 nm (two lamps each)
UseStandalone or connected to puriFlash
SafetyLamps switch off automatically when the drawer is opened
Weight5.9 kg

Product description

A TLC plate is the fastest way to monitor the progress of a reaction in organic chemistry. However, visual assessment of the plate in a UV cabinet is subjective and leaves no permanent record.

The TLC-FlashReader images the plate in a closed drawer under three different light sources: white light, 254 nm and 366 nm UV. The image is saved digitally, providing a photo to attach to the laboratory notebook or an image to add to a report.

The plate image can also be transferred directly to the Genius module in the ClearPeak software. Genius suggests a suitable flash gradient and column size from the position of the TLC spots (Rf values); moving from TLC to a purification method requires no manual calculation.

TLC plate reader operating modes

  • Standalone mode: Connects to a computer with its own software; plates are imaged and archived.
  • Connected mode: Pairs with puriFlash 5th generation, XS 530 and 535-XL systems; the plate is transferred directly to the instrument software.

When the drawer is opened, the lamps switch off automatically; the user is not exposed to UV radiation. The plate holder is removable, making it easy to clean.

Recording reaction monitoring is valuable for patent and quality audits; a hand-drawn TLC sketch is no substitute for a digital image.

Role in the purification workflow

The TLC-FlashReader is used for method preparation before purification and for fraction checking afterward. The method generated from the plate image is transferred to systems such as the puriFlash XS 530, puriFlash 5.020 and puriFlash 535-XL. Which of the collected fractions are to be combined is also determined using TLC plates recorded with the same reader.

If the identity of the spots needs to be confirmed with mass information, the Plate Express TLC-MS interface is used. All TLC solutions are listed in the TLC systems section.

Correct use and common mistakes

Imaging a plate before it is fully dry causes spots to appear blurred due to solvent residue; the plate should therefore be dried before imaging. In addition, recording the same plate under both 254 nm and 366 nm prevents spots visible at only one wavelength from being missed. Adding sample and reaction information to archived images also makes later comparisons easier.

The reader's plate holder should be cleaned regularly; silica dust or stain residue left on the holder can create false spots in subsequent images. Since the holder is removable, this cleaning takes little time.

Technical assessment of the TLC plate reader

The instrument can also be used on its own; however, it delivers the greatest benefit together with puriFlash systems. If a flash system is already in place, compatibility is checked before ordering.

Versions with and without a tablet are available; the appropriate configuration is determined at the quotation stage.

Technical specifications

Accepted platesAny TLC plate up to 8.5 cm wide and 12.5 cm high
Light sourcesWhite light (2 lamps), UV 254 nm (2 lamps), UV 366 nm (2 lamps)
Operating modesStandalone software or connected to ClearPeak
CompatibilitypuriFlash 5th generation, XS 530, 535-XL
Connection2 USB cables
SafetyLamps switch off automatically when the drawer is opened
MaintenanceRemovable plate holder
Power supply110 V or 220 V
Weight5.9 kg

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Which plates does the TLC-FlashReader accept?

TLC plates up to 8.5 cm wide and 12.5 cm high can be read.

Can the instrument be used without puriFlash?

Yes. In standalone mode it connects to a computer with its own software; plates are imaged and archived. In connected mode, the image is transferred directly to the purification system software.

Is the user exposed to UV light?

No. The plate is imaged in a closed drawer, and the lamps switch off automatically when the drawer is opened.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote