DUKO LifeDUKO Life
DLAB D1524R refrigerated microcentrifuge with LCD display and lid

DLAB

D1524R and DG1616R Refrigerated Centrifuge

The refrigerated centrifuge series includes two models for separating heat-sensitive samples such as enzymes, proteins and nucleic acids at low temperature. The D1524R delivers 21,380×g with microtubes and cools down to -20 °C; the DG1616R offers 16,000 rpm and 28,621×g with a 7-inch touchscreen.

Request a quote
Maximum speed15,000 rpm (D1524R) · 16,000 rpm (DG1616R)
Maximum RCF21,380×g (D1524R) · 28,621×g (DG1616R)
Temperature range-20 °C to 40 °C (D1524R) · -10 °C to 40 °C (DG1616R)
Pre-coolingFrom room temperature to 4 °C in 7 min (D1524R)
DisplayLCD (D1524R) · 7-inch touchscreen (DG1616R)

Product description

A refrigerated centrifuge holds the rotor chamber at the set temperature while spinning at high speed. During long high-speed runs, friction and motor heat can warm the sample; cooling is therefore essential in protocols where enzyme activity or protein structure must be preserved.

The D1524R is a benchtop model that works with microtubes. The temperature is set between -20 °C and 40 °C, and the chamber cools from room temperature to 4 °C in approximately 7 minutes; if the set value is below ambient, the compressor starts pre-cooling automatically. It provides 10 program memories, 9-level acceleration/deceleration, an imbalance alarm and an electromagnetic lid lock.

The DG1616R, with its 7-inch touch interface and 16,000 rpm speed, is aimed at a wider range of applications. It offers a maximum force of 28,621×g, temperature control from -10 °C to 40 °C and timed operation up to 99 hours 59 minutes or continuous operation.

Model comparison

ModelSpeed rangeMax. RCFTemperature rangeDisplayPowerWeight
D1524R200–15,000 rpm21,380×g-20 °C to 40 °CLCD500 W30 kg
DG1616R300–16,000 rpm28,621×g-10 °C to 40 °C7-inch touchscreen1,050 W90 kg

The D1524R is used with rotor options for 24 × 1.5/2 mL, 36 × 0.2/0.5 mL, 4 × PCR8 strips and 12 or 18 × 5 mL. For the DG1616R, the rotor and adapter selection is determined according to the application at the quotation stage.

Applications

  • Low-temperature precipitation in enzyme and protein work
  • Temperature-sensitive nucleic acid protocols such as RNA isolation
  • Cell fractionation and organelle separation steps
  • Sample processing requiring a cold chain in biobanking and clinical research

Typical workflows by industry are summarized on the applications page.

Correct use and maintenance

In a refrigerated centrifuge, condensation can form in the chamber after operation. The chamber is dried by leaving the lid open for a while; if accumulated water is not wiped off, there is a risk of icing and corrosion over time.

Sample tubes are placed after the chamber has reached the target temperature. If the rotor and adapters are pre-cooled, temperature equilibrium is reached faster in the first run.

Refrigerated centrifuge selection criteria

  • Tube format: If work is mainly done with 1.5/2 mL microtubes, the D1524R is sufficient.
  • Force and volume: For applications requiring more than 21,380×g or a larger rotor, the DG1616R should be considered.
  • Placement: The DG1616R weighs 90 kg and measures 623 × 640 × 375 mm; a sturdy bench or stand is required.
  • Electrical: The DG1616R draws 1,050 W; a dedicated power circuit is recommended.

For microtube work that does not require cooling, a high-speed microcentrifuge, and for large-volume rotors, a high-speed benchtop centrifuge are more economical options. All models are found in the centrifuges and vacuum category.

Technical specifications

Speed range200–15,000 rpm, 100 rpm increments (D1524R) · 300–16,000 rpm, 1 rpm increments (DG1616R)
Maximum RCF21,380×g, 10×g increments (D1524R) · 28,621×g, 1×g increments (DG1616R)
Speed accuracy±20 rpm (DG1616R)
Temperature range-20 °C to 40 °C (D1524R) · -10 °C to 40 °C (DG1616R)
Run time30 s to 99 min, continuous (D1524R) · 30 s to 99 h 59 min 59 s, continuous (DG1616R)
Acceleration / deceleration25 s / 25 s (D1524R) · 9 levels (DG1616R)
Program memory10 programs (D1524R)
MotorBrushless DC
Noise≤56 dB (D1524R)
Power500 W (D1524R) · 1,050 W (DG1616R)
Power supply100–120 V / 200–240 V, 50/60 Hz
Dimensions (W × D × H)332 × 553 × 283 mm (D1524R) · 623 × 640 × 375 mm (DG1616R)
SafetyDual lid lock, overspeed and overtemperature detection, self-diagnosis, imbalance alarm

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is pre-cooling used for?

The chamber is brought to the target temperature before the sample is placed, so the sample does not warm up during the first minutes of the run. On the D1524R, the chamber cools from room temperature to 4 °C in approximately 7 minutes.

Is a refrigerated centrifuge necessary for every protocol?

No. Most routine plasmid and DNA work is carried out at room temperature. Cooling is required for temperature-sensitive samples such as RNA, enzymes and proteins, or for long high-speed runs.

Can the rotors be autoclaved?

The high-strength aluminum alloy rotors of the D1524R are fully autoclavable at 121 °C and feature a three-layer seal.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.