DUKO LifeDUKO Life
DLAB D1008 mini centrifuge with transparent lid and 8-place rotor

DLAB

D1008 and D1012UA Mini Centrifuge

The mini centrifuge series consists of compact instruments designed for short operations such as PCR preparation and collecting droplets from the tube wall. The D1008 reaches 7,000 rpm when the lid is closed; the D1012UA offers 10,000 rpm and time and speed setting via its OLED display.

Request a quote
Maximum speed7,000 rpm (D1008) · 10,000 rpm (D1012UA)
Maximum RCF2,680×g (D1008) · up to 7,490×g (D1012UA)
Capacity8 × 2 mL or 4 × PCR8 (D1008) · 12 × 2 mL + 4 × PCR8 (D1012UA)
Run timeContinuous (D1008) · 10 s to 20 min (D1012UA)
Weight0.6 kg (D1008) · 1.5 kg (D1012UA)

Product description

A mini centrifuge is a small instrument kept ready on the bench that collects liquid adhering to the tube wall at the bottom with spins of a few seconds. It is used when preparing PCR mixes, in intermediate steps of nucleic acid extraction and to collect reagents from the cap, without occupying a larger centrifuge.

The D1008 has a dual start and stop design: it starts running when the lid is closed and stops when it is opened. It reaches 7,000 rpm within seconds and brakes; operating noise does not exceed 45 dB. The rotor is mounted with a clamp lock design and changed without tools. The instrument is offered in blue and green color options.

The D1012UA reaches 10,000 rpm, and users can switch between speed and time on its OLED display. Thanks to wide-voltage technology, the speed is not affected by fluctuations in mains voltage. Soft braking and quick stop modes can be selected.

Model comparison

ModelMax. speedMax. RCFRotor capacityNoiseWeight
D10087,000 rpm2,680×g8 × 0.2/0.5/1.5/2 mL · 32 × 0.2 mL PCR · 4 × PCR8 strips≤45 dB0.6 kg
D1012UA10,000 rpm6,708×g (1.5/2 mL) · 6,596–7,490×g (PCR8)12 × 0.5/1.5/2 mL + 4 × PCR8 strips · 44 × 0.2 mL PCR≤58 dB1.5 kg

Applications

  • Quick spin-down when preparing PCR and qPCR mixes
  • Collecting droplets from the tube wall in DNA and RNA work
  • Intermediate steps of nucleic acid extraction
  • Processing of small-volume samples before and after experiments

Correct use and maintenance

In a mini centrifuge too, tubes must be placed opposite each other in the rotor with equal volumes. If a single tube is to be spun, a balance tube filled with the same volume of water is placed opposite it; an unbalanced load increases vibration and wears the rotor bearings over time.

Tubes with caps that are not fully closed can open during the run and contaminate the rotor. Caps are therefore checked before starting, and the rotor and chamber are wiped with a damp cloth at regular intervals. In case of a spill, the rotor is removed and the parts are cleaned separately.

Mini centrifuge selection criteria

  • Speed requirement: For collecting droplets only, the D1008 is sufficient; if small precipitates need to be separated, the D1012UA with its higher RCF is selected.
  • Time control: If reproducible run times are required, the D1012UA, adjustable between 10 seconds and 20 minutes, is suitable.
  • Capacity: If 1.5/2 mL tubes and PCR strips need to be spun at the same time, the combined rotor of the D1012UA is preferred.

For extraction and purification steps in microtubes that require higher force, a high-speed microcentrifuge is used. The mini centrifuge is usually part of the same workflow as a vortex mixer and a PCR thermal cycler. All models are found in the centrifuges and vacuum category.

Technical specifications

Maximum speed7,000 rpm (D1008) · 10,000 rpm (D1012UA)
Maximum RCF2,680×g (D1008) · 6,708×g, 1.5/2 mL (D1012UA)
Rotor capacityDepending on model, see comparison table
Run timeContinuous (D1008) · 10 s to 20 min (D1012UA)
MotorDC motor
DisplayNone (D1008) · OLED (D1012UA)
Noise≤45 dB (D1008) · ≤58 dB (D1012UA)
Power supplyAC 100–240 V, 50/60 Hz; 20 W (D1008) · 40 W (D1012UA)
Dimensions (D × W × H)160 × 170 × 122 mm (D1008) · 210 × 180 × 130 mm (D1012UA)
Weight0.6 kg (D1008) · 1.5 kg (D1012UA)
Color optionsBlue or green (D1008)
CertificationsCE, UKCA, FCC, ICES, CB, cTUVus

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between a mini centrifuge and a high-speed microcentrifuge?

A mini centrifuge is designed for short spins in the range of a few thousand g and collects liquid at the bottom of the tube. A high-speed microcentrifuge reaches 15,000 rpm and more than 20,000×g and is used in precipitate separation and purification steps.

Does the D1008 have a timer?

The D1008 is designed for continuous operation; it spins when the lid is closed and stops when it is opened. If timed operation is required, the D1012UA is preferred.

Can PCR strips and 2 mL tubes be spun at the same time?

The rotor of the D1012UA holds 12 × 0.5/1.5/2 mL tubes together with 4 PCR8 strips at the same time. On the D1008, the tube rotor and the PCR strip rotor are mounted separately.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote