DLAB DG1616 high-speed benchtop centrifuge with touchscreen

DLAB

DM1224, DM1424 and DG1616 High-Speed Centrifuge

The high-speed benchtop centrifuge series consists of models for two different needs. The DM1224 and DM1424 reach 12,000 rpm and 13,680×g with a 24-place capillary tube rotor; the DG1616 offers 16,000 rpm, 28,621×g and capacity up to 4 × 400 mL.

Request a quote
Maximum speed12,000 rpm (DM1224, DM1424) · 16,000 rpm (DG1616)
Maximum RCF13,680×g (DM) · 28,621×g (DG1616)
Capacity24 × capillary tubes (DM) · up to 4 × 400 mL (DG1616)
DisplayLCD (DM) · 7-inch touchscreen (DG1616)
MotorBrushless DC

Product description

The centrifuges on this page are designed for tasks that exceed the capacity or rotor type of microcentrifuges. The DM1224 and DM1424 are high-speed models operating with a 24-place capillary tube rotor. Capillary tube centrifuges are used for small-volume separations such as hematocrit determination in blood samples.

The DM1424 is adjustable from 200 to 12,000 rpm in 10 rpm increments and provides ±20 rpm speed accuracy; it includes automatic rotor recognition, overspeed and overtemperature detection and automatic self-diagnosis. The DM1224 is a simpler model with a lid lock, operating from 500 to 12,000 rpm in 100 rpm increments.

The DG1616 reaches 16,000 rpm and 28,621×g, with a capacity of up to 4 × 400 mL. It offers a 7-inch touch interface, a magnetic lid lock that closes with one hand, programs that can be saved and 9-level acceleration/deceleration. Its aluminum alloy rotors can be autoclaved at 121 °C.

Model comparison

ModelSpeed rangeMax. RCFCapacitySpeed accuracyPowerWeight
DM1224500–12,000 rpm13,680×g24 × capillary tubes±100 rpm380 W8.5 kg
DM1424200–12,000 rpm13,680×g24 × capillary tubes±20 rpm160 W10.5 kg
DG1616300–16,000 rpm28,621×gUp to 4 × 400 mL±20 rpm650 W70 kg

Applications

  • Hematocrit and small-volume blood separation with capillary tubes (DM series)
  • Pelleting of large-volume cell suspensions and culture media (DG1616)
  • Separations requiring high force in biochemistry and microbiology laboratories
  • Routine clinical laboratory centrifugation

Correct use and maintenance

Before being placed in the rotor, capillary tubes are sealed at one end with sealing compound and positioned with the sealed end facing outward. Broken or cracked capillary tubes should not be used, as they can contaminate the rotor chamber at high speed.

In large-volume rotors, the weights of bottles in opposite positions should be close to each other. Balancing by weighing is more reliable than equalizing volumes. Rotors are cleaned and dried after use; the aluminum rotors of the DG1616 can be autoclaved at 121 °C when required.

When the rotor is changed, the maximum speed is limited to the value permitted by the rotor. The rotor and adapters to be used are therefore determined together before ordering, based on the force value in the protocol.

High-speed benchtop centrifuge selection criteria

  • Sample format: For capillary tube work, the DM1224 or DM1424 is selected; for conical tubes and bottles, the DG1616 is selected.
  • Speed precision: If protocol reproducibility is important, the DM1424 with ±20 rpm accuracy and automatic rotor recognition is preferred.
  • Temperature: For large-volume heat-sensitive samples, the refrigerated DG1616R should be considered.

The refrigerated version of the DG1616 is on the refrigerated centrifuge page. For routine work with 15 and 50 mL tubes, a low-speed centrifuge and compatible conical centrifuge tubes are considered together. All options are found in the centrifuges and vacuum category.

Technical specifications

Speed range500–12,000 rpm (DM1224) · 200–12,000 rpm (DM1424) · 300–16,000 rpm (DG1616)
Speed increment100 rpm (DM1224) · 10 rpm (DM1424) · 1 rpm (DG1616)
Maximum RCF13,680×g (DM1224, DM1424) · 28,621×g (DG1616)
Run time10 s to 99 min (DM1224) · 30 s to 99 min (DM1424) · 30 s to 99 h 59 min 59 s (DG1616); continuous operation
Acceleration / deceleration40 s / 40 s (DM1224) · 30 s / 30 s (DM1424) · 9 levels (DG1616)
DisplayLCD (DM) · 7-inch touchscreen (DG1616)
MotorBrushless DC
SafetyLid lock; overspeed detection, self-diagnosis and automatic rotor recognition on the DM1424
Other functionsSpeed/RCF switching, short spin, audible alarm (DM series)
Power supplySingle phase 200–240 V; 100–120 V option for the DM1424 and DG1616
Dimensions (W × D × H)280 × 364 × 213 mm (DM1224) · 280 × 364 × 274 mm (DM1424) · 440 × 640 × 375 mm (DG1616)

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is a capillary tube centrifuge used for?

A capillary tube centrifuge is used to separate very small-volume blood samples at high speed; its most common application is hematocrit determination.

What is the difference between the DM1224 and the DM1424?

Both models reach 13,680×g with a 24-place capillary tube rotor. The DM1424 offers finer speed increments, ±20 rpm speed accuracy, automatic rotor recognition and additional safety detection functions.

Does the DG1616 provide cooling?

The DG1616 is a non-refrigerated model. If cooling is required at the same speed and force values, the DG1616R, which cools down to -10 °C, is selected.