The DLAB thermomixer heats samples in tubes while mixing them at 200–1,500 rpm with a 3 mm orbit. The HM100-Pro heats and mixes, while the HCM100-Pro also cools down to 15 °C below ambient; both models are available in versions with mechanical or magnetic block fixing.

Request a quote
Temperature range15 °C below ambient to 100 °C (HCM100-Pro)
Mixing speed200–1,500 rpm
Orbit3 mm
Programs9 programs
DisplayTFT

Product description

A thermomixer combines the temperature control of a dry block heater with the motion of a mixer. Because the sample is mixed continuously while it is heated, temperature and reagent distribution within the tube are more homogeneous, and a separate vortexing step is no longer needed.

The DLAB HM100-Pro and HCM100-Pro thermomixers show speed, temperature and time simultaneously on a TFT display. Blocks are exchanged without tools, and the instrument automatically recognizes the installed block. Both models are offered in two versions of block attachment: mechanical fixing and magnetic fixing.

Model comparison

ModelFunctionTemperature rangeCooling rateMixing
HM100-Pro (mechanical / magnetic)Heating and mixingRoom temperature to 100 °C (setting 15–100 °C)None200–1,500 rpm, 3 mm
HCM100-Pro (mechanical / magnetic)Heating, cooling and mixing15 °C below ambient to 100 °C (setting 0–100 °C)5 °C/min (from 100 °C to ambient) · 0.5 °C/min (below ambient)200–1,500 rpm, 3 mm

On both models, the maximum heating rate is 5.5 °C/min, and temperature control accuracy and uniformity in the 20–45 °C range are ±0.5 °C. Overheat protection is triggered at 150 °C.

Applications

  • DNA, RNA and plasmid isolation and purification
  • Sample lysis and proteinase K digestion
  • Restriction digestion and ligation
  • Nucleic acid and protein denaturation
  • PCR mix preparation
  • Bacterial culture and pellet resuspension

With its cooling function, the HCM100-Pro allows protocols that require bringing the sample below ambient temperature after the reaction to be run without switching to a second instrument.

Correct use

The mixing speed should be selected according to tube volume and fill level. In completely full tubes, high speeds can cause leakage around the cap; it is therefore recommended to start at low speed and to check the tube caps. Saving heating and mixing steps as programs allows the same protocol to be applied reproducibly by different users. Keeping the block lid closed also limits condensation on the tube caps and heat loss at high temperatures.

Thermomixer selection criteria

  • Cooling requirement: If the protocol includes a below-ambient step, the HCM100-Pro is selected; if it involves only heating and mixing, the HM100-Pro is selected.
  • Block attachment: If fast block exchange is the priority, the magnetic version is preferred; if the block should be mechanically locked to the housing, the mechanical version is preferred.
  • If mixing is not required: For temperature control only, the H100-Pro and HC110-Pro thermo control blocks are a more economical option.

For tube mixing tasks that do not require heating, MX series vortex mixers can be used; to hold a large number of tubes at a constant temperature, HB series dry block heaters can be used. Other options are found in the heating and temperature control category.

Technical specifications

FunctionHeating and mixing (HM100-Pro) · heating, cooling and mixing (HCM100-Pro)
Temperature rangeRoom temperature to 100 °C (HM100-Pro) · 15 °C below ambient to 100 °C (HCM100-Pro)
Temperature setting range15–100 °C (HM100-Pro) · 0–100 °C (HCM100-Pro)
Control accuracy (20–45 °C)±0.5 °C
Uniformity (20–45 °C)±0.5 °C
Heating rateUp to 5.5 °C/min
Cooling rate (HCM100-Pro)5 °C/min (from 100 °C to ambient) · 0.5 °C/min (below ambient)
Mixing speed200–1,500 rpm
Orbit3 mm
Timer0 min to 99 h 59 min
Program memory9
Overheat protection150 °C
DisplayTFT
Power200 W
Power supply110/220 V, 50/60 Hz
Dimensions and weight200×235×120 mm · 7.3 kg

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between a thermomixer and a dry block heater?

A dry block heater only controls temperature. A thermomixer also mixes the tubes at 200–1,500 rpm, so reagent and temperature distribution remain homogeneous during heating.

Is there a performance difference between the mechanical and magnetic versions?

No, both versions have the same temperature and mixing specifications. The difference lies in how the block is fixed to the housing and how convenient block exchange is.

Which tubes can be used?

Interchangeable blocks are offered to fit common tube types. The suitable block combination is determined at the quotation stage based on the tube size and quantity to be used.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote