DUKO LifeDUKO Life
DLAB TopPette adjustable-volume single-channel mechanical pipette

DLAB

TopPette Mechanical Pipette

The TopPette adjustable-volume mechanical pipette family is designed for everyday pipetting with low plunger force and a digital volume display. The pipettes are calibrated to ISO 8655 and each is delivered with an individual test certificate.

Request a quote
Channels1, 8 or 12
Volume range0.1 µL–20 mL (single-channel)
CalibrationISO 8655, certificate per pipette
AutoclaveLower part autoclavable
DisplayDigital volume display

Product description

TopPette is a mechanical pipette family developed for routine pipetting, with a lightweight body and low plunger force. The digital volume display allows the set value to be read clearly; the pipettes are calibrated to ISO 8655 and each comes with an individual test certificate.

The lower part of the pipette is autoclavable and resistant to aggressive chemicals. Removable parts and the supplied tools allow calibration and maintenance to be performed in the laboratory.

Among the single-channel models, there is also a corded version with an on/off switch for use with instruments that require precise timing, such as coagulation analyzers. The 8- and 12-channel models are compatible with 96-well plates and are also offered as the model the manufacturer calls magnetic (magnetic suction).

Model comparison

ModelChannelsVolume ranges
TopPette single-channel10.1–2.5 µL · 0.5–10 µL · 2–20 µL · 5–50 µL · 10–100 µL · 20–200 µL · 50–200 µL · 100–1000 µL · 200–1000 µL · 500–5000 µL · 1000–5000 µL · 1000–10000 µL · 2000–10000 µL · 2000–20000 µL
TopPette 8-channel magnetic80.5–10 µL · 5–50 µL · 10–100 µL · 20–200 µL · 50–200 µL · 30–300 µL · 50–300 µL
TopPette 12-channel120.5–10 µL · 5–50 µL · 50–300 µL
TopPette 8-channel80.5–10 µL · 5–50 µL · 50–300 µL
TopPette 12-channel magnetic120.5–10 µL · 5–50 µL · 10–100 µL · 20–200 µL · 30–300 µL · 50–300 µL

The accuracy values published by the manufacturer for the single-channel TopPette at the maximum test volume are as follows.

Volume rangeIncrementSystematic error (at maximum volume)Random error (at maximum volume)
0.1–2.5 µL0.05 µL±0.0625 µL ±2.5%±0.05 µL ±2.00%
0.5–10 µL0.1 µL±0.1 µL ±1.00%±0.08 µL ±0.80%
2–20 µL0.5 µL±0.18 µL±0.08 µL
5–50 µL0.5 µL±0.3 µL ±0.60%±0.15 µL ±0.30%
10–100 µL1 µL±0.80 µL ±0.80%±0.15 µL ±0.15%
20–200 µL1 µL±1.20 µL ±0.60%±0.30 µL ±0.15%
50–200 µL1 µL±1.20 µL ±0.60%±0.30 µL ±0.15%
100–1000 µL5 µL±6.00 µL ±0.60%±2.00 µL ±0.20%
200–1000 µL5 µL±6.00 µL ±0.60%±2.00 µL ±0.20%
500–5000 µL50 µL±25.00 µL ±0.50%±7.50 µL ±0.15%
1000–5000 µL50 µL±25.00 µL ±0.50%±7.50 µL ±0.15%
1000–10000 µL100 µL±60.00 µL ±0.60%±20.00 µL ±0.20%
2000–10000 µL100 µL±60.00 µL ±0.60%±20.00 µL ±0.20%
2000–20000 µL100 µL±120.00 µL ±0.60%60.00 µL ±0.30%

Applications

  • Pipetting that requires traceable calibration in quality control and analytical laboratories
  • Timed dispensing with coagulation analyzers in clinical laboratories (switch version)
  • Preparation of buffers and solutions at the milliliter level (up to 20 mL)
  • 8- and 12-channel dispensing into 96-well plates

Selection criteria for adjustable-volume mechanical pipettes

In laboratories where calibration certificates are required during audits, the individual test certificate supplied with each TopPette is a practical advantage. If a fully autoclavable body is required, the HiPette or MicroPette Plus series are more suitable.

For serial dispensing and repetitive pipetting, the StepMate repeater pipette can be considered, and for volumes above 10 mL, pipette controllers. Compatible tips are in the pipette tips category.

The pipette's accuracy performance is best exploited when the volume range is selected so that the most frequently used volume falls in the upper half of the range.

Technical specifications

Number of channels1, 8 or 12
Volume range0.1 µL–20 mL (single-channel), 0.5–300 µL (8 and 12 channels)
Volume displayDigital
CalibrationTo ISO 8655, test certificate per pipette
AutoclaveLower part autoclavable
Chemical resistanceLower part resistant to aggressive chemicals
MaintenanceCalibration and maintenance tools supplied
Special versionCorded single-channel model with on/off switch
ComplianceRoHS

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the main difference between TopPette and HiPette?

On TopPette, the lower part of the pipette is autoclavable and each pipette comes with an individual test certificate. HiPette has a fully autoclavable body. The choice depends on sterilization needs and calibration documentation requirements.

What is the switch version of TopPette used for?

The version with an on/off switch and cable is designed for applications where dispensing must be timed with an instrument, such as coagulation analyzers.

Can pipette calibration be performed in the laboratory?

The tools supplied with the pipette allow calibration and maintenance to be performed in the laboratory. A precision balance and pure water of known temperature are used for gravimetric checks.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote