DLAB
MX-T6 Tube Roller and SK-R30 Rocking Rotator
Tube rollers and rocking rotators mix blood collection tubes and centrifuge tubes in batches by rolling them or rocking them on a tilted plane. The MX-T6 series offers six-roller rolling, while the SK-R30 series offers rocking motion on short, long and double-layer platforms.
Request a quote| Motion | Rolling and rocking (MX-T6) · rocking rotation (SK-R30) |
|---|---|
| Speed range | 0–70 rpm (MX-T6) · 0–30 rpm (SK-R30) |
| Load capacity | 4 kg (MX-T6) · 1 kg (SK-R30) |
| Rollers | 6, 280 mm (MX-T6) |
| Motor | Brushless DC |
Product description
In tubes containing blood and viscous liquids, mixing must be slow and continuous to avoid damaging cells. The MX-T6 tube roller rotates tubes on six rollers while simultaneously rocking them with a 24 mm amplitude; this combined motion disperses sediment in the contents quickly. The rollers are easy to clean, and the instrument can be used in cold rooms and incubators.
The SK-R30 rocking rotators move tubes back and forth at a fixed tilt angle. Short, long and double-layer long platform options adapt to different tube loads in clinics and blood banks. Silicone mat accessories prevent the tubes from slipping.
Model comparison
| Model | Motion | Speed range | Control | Load / tilt | Dimensions (D × W × H) |
|---|---|---|---|---|---|
| MX-T6-Pro | Rolling and rocking | 10–70 rpm | LCD, 1–1,199 min timer | 4 kg | 485 × 250 × 100 mm |
| MX-T6-S+ | Rolling and rocking | 0–70 rpm | Scale, continuous | 4 kg | 485 × 250 × 100 mm |
| SK-R30S-E | Rocking rotation | 0–30 rpm | Continuous | 1 kg, 30° ±3° | 295 × 160 × 120 mm |
| SK-R30L-E | Rocking rotation | 0–30 rpm | Continuous | 1 kg, 30° ±3° | 405 × 160 × 120 mm |
| SK-R30D-E | Rocking rotation, double layer | 0–30 rpm | Continuous | 1 kg, 40° ±3° | 405 × 160 × 160 mm |
Applications
- Standardized mixing of blood collection tubes before analysis
- Batch sample pretreatment in hospital laboratories and blood banks
- Keeping cell suspensions and viscous reagents homogeneous
- Long-term gentle mixing in cylindrical vessels
Correct use
Tubes are placed parallel to the rollers with spacing between them; overlapping tubes do not rotate evenly. The load capacity must not be exceeded: observing the 4 kg limit for the MX-T6 and the 1 kg limit for the SK-R30 protects motor life. The rollers and silicone mats are cleaned by wiping with disinfectant.
For blood tubes, mixing time is determined according to the laboratory's own procedure; the timer on the MX-T6-Pro keeps this time identical for every batch. The instrument should be installed on a flat, vibration-free surface; a sloping surface causes tubes to slide to one end.
Tube roller selection criteria
The MX-T6 series suits heavy loads and large numbers of tubes, while the SK-R30 series suits a lighter, more compact solution. If mixing time is to be recorded in the protocol, the MX-T6-Pro with LCD display and timer is preferred. If bench space is limited, the double-layer SK-R30D-E provides twice the tube capacity on the same footprint.
If tubes need to be mixed by 360° rotation, the MX-RD and MX-RL tube rotator is used, and a vortex mixer for fast single-tube mixing. Other options are in the mixing and shaking category; for clinical use, see the applications page.
Technical specifications
| Motion type | MX-T6: rolling and rocking · SK-R30: rocking rotation |
|---|---|
| Speed range | MX-T6-Pro: 10–70 rpm · MX-T6-S+: 0–70 rpm · SK-R30: 0–30 rpm |
| Amplitude | 24 mm (MX-T6) |
| Tilt angle | SK-R30S/L-E: 30° ±3° · SK-R30D-E: 40° ±3° |
| Rollers | 6, 280 mm length (MX-T6) |
| Load capacity | MX-T6: 4 kg · SK-R30: 1 kg |
| Timer | 1–1,199 min (MX-T6-Pro) |
| Motor | Brushless DC |
| Power | MX-T6: 25–30 W · SK-R30: 15 W |
| Power supply | 100–240 V, 50/60 Hz |
| Weight | MX-T6: 4.5–5.1 kg · SK-R30: 1.8–2.2 kg |
| Ambient conditions | 5–40 °C, 80% relative humidity |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
Does a tube roller damage blood tubes?
No. The low-speed rotation of the rollers and the gentle rocking motion are designed to mix the contents without disrupting cells.
Can the MX-T6 be used inside an incubator?
Yes. The manufacturer states that the MX-T6-Pro is compatible with cold rooms and incubators; ambient conditions must remain within the limits in the technical table.
What does platform length change in the SK-R30 series?
The short platform saves space for a small number of tubes; the long and double-layer platforms allow more tubes to be mixed simultaneously. The load limit is 1 kg on every model.
From the same category

OS Series Mechanical (Overhead) Stirrer
OS series overhead stirrers with brushless motors for water-equivalent volumes of up to 20, 40 and 70 liters.

MS-H Series Hotplate Stirrer
MS-H series hotplate stirrers with a 5-inch plate, heating up to 340 °C and stirring up to 20 L of water.

Multi-Position Magnetic Stirrers
Parallel sample preparation with 4-, 6-, 10- and 15-position DLAB magnetic stirrers, with or without heating.

MS, FlatSpin and EcoStir Magnetic Stirrers
Non-heating DLAB magnetic stirrers, from the ultra-slim FlatSpin to the MS7-S with a 7-inch glass-ceramic plate.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote