Advion Interchim Scientific
Uptisphere Strategy Analytical HPLC Columns
Uptisphere Strategy is a scalable analytical HPLC column series offering the same phase from 1.7 µm to 15 µm. With C18-HQ, PHC4, HILIC and silica phases in 2.1–4.6 mm internal diameters, it simplifies the transition from analytical to preparative scale.
Request a quote| Phases | C18-HQ, C18-3, C18-RP, PHC4, HILIC-HIA/HIT, SI, C12, BPH, PFP |
|---|---|
| Particle size | 1.7–15 µm (depending on phase) |
| Internal diameter | 2.1 / 3.0 / 4.0 / 4.6 mm |
| Length | 25–300 mm |
| Pore size | 100 Å |
Product description
Uptisphere Strategy is Interchim's analytical HPLC column series. The key feature of the series is that the same phase is manufactured in particle sizes ranging from 1.7 µm to 15 µm. A method developed at analytical scale can be transferred to a preparative column without changing the phase chemistry, which reduces surprises caused by selectivity differences during scale-up.
The columns are offered in 2.1, 3.0, 4.0 and 4.6 mm internal diameters and in lengths from 25 mm to 300 mm. 10 × 10 mm guard column cartridges and a holder are also available to protect the columns.
Scalable analytical HPLC column phases
- C18-HQ: 100 Å, 425 m²/g, 19% carbon, pH 1–10; general-purpose reversed phase with a wide pH range
- C18-3 and C18-RP: C18 alternatives with different selectivity; a second option in method development
- PHC4: Selectivity different from C18 through phenyl and aromatic interactions
- HILIC-HIA and HILIC-HIT: Hydrophilic interaction chromatography for highly polar compounds not retained on C18
- SI: Normal phase analytical separations
- BPH, PFP, C12: Separations requiring special selectivity, such as positional isomers and halogenated compounds
Technical evaluation
Particle size is selected according to the pressure limit of the instrument. 1.7 and 2.2 µm columns deliver high resolution in a short time on UHPLC systems; 3 and 5 µm columns are common on standard HPLC systems; 10 and 15 µm options are for the transition to preparative scale. In the Interchim catalog these columns are listed with a 500 bar label; the maximum pressure for the dimension to be used is confirmed against the data sheet.
Pore size, surface area and pH range are taken from Interchim catalogs and should be confirmed against the current data sheet for the phase and format to be ordered.
Reversed phase, HILIC and chiral options from other brands are listed on the HPLC columns page, and preparative versions of the same phases on the preparative HPLC column page.
The risk of particle-related clogging is higher with 1.7 and 2.2 µm columns; passing samples through UptiDisc syringe filters and transferring them to 9 mm screw HPLC vials is recommended. At preparative scale, the same phases can be used with preparative HPLC systems such as the puriFlash 5.250.
Correct use
When a new column is put into service, it is equilibrated with the recommended mobile phase and the initial pressure value is recorded. This reference makes it easier to tell whether increasing backpressure in the following weeks is caused by clogging or by a change in mobile phase. In addition, regular replacement of the guard column cartridge protects the analytical column.
Technical specifications
| C18-HQ | 100 Å, 425 m²/g, 19% C, pH 1–10; 1.7 / 2.2 / 3 / 5 / 10 / 15 µm |
|---|---|
| C18-3 | 100 Å, 425 m²/g; 3 / 5 / 10 / 15 µm |
| C18-RP, PHC4, HILIC-HIA, HILIC-HIT | 2.2–15 µm (PHC4 and HILIC-HIA: 100 Å, 300 m²/g; HILIC-HIA pH 2–7) |
| SI | 2.2–10 µm |
| C12 | 2.2 / 5 µm |
| BPH, PFP | 3 / 5 µm |
| Internal diameter | 2.1 / 3.0 / 4.0 / 4.6 mm |
| Length | 25 / 30 / 50 / 75 / 100 / 125 / 150 / 250 / 300 mm |
| Guard column | 10 × 10 mm cartridge and holder |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
How is an analytical method transferred to preparative scale?
A column with the same phase in a preparative particle size is selected; the flow rate is increased in proportion to the square of the internal diameter and the sample load in proportion to the column volume. A preparative column dimension and flow recommendation is prepared based on the analytical method.
Which particle size should be selected for UHPLC?
1.7 and 2.2 µm columns deliver high resolution in a short time on UHPLC systems. On standard HPLC systems, 3 and 5 µm columns are preferred due to the pressure limit.
How to choose between C18-HQ and PHC4?
C18-HQ is a general-purpose reversed phase with a wide pH range. If aromatic and structurally similar compounds do not separate on C18, the phenyl-interaction PHC4 offers a different selectivity.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote