Stainless steel preparative HPLC column puriFlash PREP

Advion Interchim Scientific

Preparative HPLC Columns (puriFlash PREP and Uptisphere)

The preparative HPLC column family delivers high-purity preparative separations with puriFlash PREP and Uptisphere Strategy phases, 5–15 µm particles and 4.6–60 mm internal diameters.

Request a quote
SeriespuriFlash PREP, puriFlash BIO, Uptisphere Strategy
Particle size5, 10, 15 µm
Internal diameter4.6 / 10 / 21.2 / 30 / 50 / 60 mm
Length50–275 mm
BodyStainless steel

Product description

Preparative HPLC columns are used for difficult separations where flash chromatography is not sufficient and for purity targets above 98 percent. Small particle size packing (5–15 µm) and a stainless steel body operating at high pressure make it possible to achieve resolution close to analytical separation at milligram and gram scale.

Interchim offers two series in this area. puriFlash PREP carries the same phase chemistry as the flash columns (C18-HP, C18-XS, C18-AQ, NH2, SI-HP, Diol) in preparative particle sizes, making it easier to transfer a method developed at flash scale to preparative scale. Uptisphere Strategy is the preparative counterpart of phases used in analytical HPLC and is suited to scaling up directly from an analytical method.

Preparative HPLC column size selection

The internal diameter of the column determines the amount of sample that can be loaded. 4.6 mm columns are used for method development and loading studies, 10 mm columns for tens of milligrams, 21.2 and 30 mm columns for hundreds of milligrams to grams, and 50 and 60 mm columns for work above gram scale. When scaling up, the flow rate is increased in proportion to the square of the internal diameter.

  • Internal diameter: 4.6, 10.0, 21.2, 30.0, 50.0, 60.0 mm
  • Length: 50, 100, 150, 250, 275 mm
  • Particle size: 5 µm for highest resolution, 10 µm for balance, 15 µm for low pressure and high load

High-pressure dry-load

For samples that are poorly soluble in the mobile phase, puriFlash high-pressure dry-load cartridges connect to preparative HPLC systems. They attach to 1/8" tubing with a 5/16"-24 (Valco-type) threaded connection and are reusable. Length options of 50–150 mm are available for 21.2 mm and 30 mm internal diameters, and 50–100 mm for 50 mm internal diameter.

Technical evaluation

The inner surface of the column bodies is typically machined to 8 µinch roughness, and the packings are packed at pressures of up to 550 bar; a sample distributor spreads the flow evenly at the bed inlet. This design helps maintain peak shape even at high loading. The maximum operating pressure of the column has not been published; compatibility with the system is confirmed at the quotation stage.

The columns are used with standard preparative HPLC systems; preparative HPLC systems such as the puriFlash 5.250 and puriFlash 5.400-UV also work with these columns. For the same phases at analytical scale, see the scalable analytical HPLC columns.

Since steel columns are reusable, the washing and storage procedure determines column life. Reversed phase columns are stored in an appropriate proportion of organic solvent; buffered mobile phase is not left inside the column.

Technical specifications

puriFlash PREP phasesC18-HP, C18-XS, C18-AQ, NH2, SI-HP (5, 10, 15 µm); RP-AQ (15 µm); Diol (10, 15 µm)
puriFlash BIO prepBIO 100 / 200 / 300 phases, 5, 10, 15 µm
Uptisphere Strategy prepC18-HQ, C18-3, C18-RP, PHC4, HILIC-HIA, HILIC-HIT (5, 10, 15 µm); SI (5, 10 µm)
Internal diameter4.6 / 10.0 / 21.2 / 30.0 / 50.0 / 60.0 mm
Length50 / 100 / 150 / 250 / 275 mm
BodyStainless steel, inner surface typically 8 µinch
Packing pressureUp to 550 bar
High-pressure dry-load5/16"-24 connection; 50–150 mm for 21.2 and 30 mm ID, 50–100 mm for 50 mm ID

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between a preparative HPLC column and a flash column?

Preparative columns operate at high pressure with 5–15 µm particles and a stainless steel body and deliver higher resolution. Flash columns use coarser particles at low pressure and are used to purify larger quantities quickly.

How is an analytical method transferred to preparative scale?

A column with the same phase chemistry in a preparative particle size is selected; the flow rate is increased in proportion to the square of the internal diameter and the sample load in proportion to the column volume.

Which particle size should be selected?

5 µm is preferred for the highest resolution, 10 µm for a balance of resolution and pressure, and 15 µm for low pressure and high loading.