puriFlash flash chromatography columns and dry-load cartridges

Advion Interchim Scientific

puriFlash Columns and Consumables

puriFlash flash chromatography columns are a family of columns and consumables offering more than thirty-five phase options for flash and preparative purification. The range includes particle sizes down to 15 µm, silica and polymer packings, and dry-load cartridges that require no piston.

Request a quote
Number of phasesMore than 35 selectivities
PackingSpherical silica and polymer
ParticleWide range including 15 µm
Dry-load4 g – 300 g, piston-free
PressureStandard 22 bar · ClearConnect 15 bar

Why column selection matters

The real factor that determines the outcome of a purification is the column, not the instrument. With the wrong phase, no separation can be achieved on the same instrument; with the right phase, pure product can be obtained in a single run.

The manufacturer packs the columns with its own packing technology and offers more than thirty-five selectivities. This covers a wide range from nonpolar to ionic compounds.

There are two main packing families. Silica is a rigid support that does not swell with solvent; its selectivity is high but its pH stability is limited (usually 2–7.5). Polymer packings are stable between pH 1 and 14 and have higher loading capacities; they are advantageous for the purification of polar compounds.

Flash chromatography column families

Interchim chromatography consumables are grouped on separate pages according to their intended use. Each page details the phase, particle size and format options:

Particle size and loading capacity

The smaller the particle size, the sharper the separation. Flash columns with 15 µm packing give separation close to preparative HPLC, so the same task can be performed in less time or with a higher load.

High-capacity columns allow more sample to be loaded on a smaller column. Solvent consumption and waste costs decrease.

  • Standard puriFlash columns: Luer-lock inlet, luer-slip outlet; stable up to 22 bar.
  • ClearConnect Premium columns: Luer-lock at inlet and outlet; fully leak-tight connection, up to 15 bar.
  • Dry-load cartridges: From 4 g to 300 g; require no piston or special adapter and withstand twice the pressure of standard cartridges.
  • Preparative LC and axial compression columns: Prepacked columns for scale-up.

Solid (dry-load) injection

If the crude sample does not dissolve in the mobile phase, liquid injection is not possible. The sample is adsorbed onto silica, C18 or diatomaceous earth and loaded dry.

Dry loading also prevents the sample from spreading at the column head. As a result, resolution, yield and the purity of the collected product increase.

The appropriate column is determined by the structure of the sample and the TLC result. When Rf values and the solvent system are provided, a phase and size recommendation is presented together with the rationale.

Technical assessment

The column is a consumable item independent of the instrument and can exceed the instrument in annual cost. Establishing a realistic consumables budget for the first year is recommended; a cost analysis can be carried out at the quotation stage.

If a flash instrument of a different brand is in use, these columns are compatible with most systems; compatibility is confirmed once the connection type is specified.

The columns are used with the puriFlash XS 530 compact flash chromatography system, puriFlash 5.020 and puriFlash 5.050; larger formats are used with pilot and process scale systems. The solvent of the collected fractions can be removed with a parallel evaporator. For an overview of the method, see the laboratory technologies page.

Frequently asked questions

Should a silica or polymer-packed column be selected?

Silica is the first choice for routine normal phase purification. For strongly acidic or basic conditions and very polar compounds, polymer packings with a wide pH range are considered.

When is a dry-load cartridge needed?

If the crude sample does not dissolve in the mobile phase, or if liquid injection causes band broadening at the column head, the sample is adsorbed onto a sorbent and loaded with a dry-load cartridge.

How is the column format selected?

The format is selected according to the amount of crude product to be purified and the difficulty of the separation. For easy separations a higher percentage of the packing mass can be loaded; difficult separations require a larger column.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.