Advion Interchim Scientific
puriFlash Reversed Phase and Functionalized Flash Columns
The puriFlash reversed phase flash column family purifies polar, ionic and chiral compounds with C18, CN, NH2, Diol, SCX, SAX, polymer and chiral phases.
Request a quote| Phase groups | Reversed phase, polar, ion exchange, polymer, chiral |
|---|---|
| Particle size | 15–100 µm (depending on phase) |
| pH range | C18-XS 1–10; Polymer X 1–13 |
| Formats | F0004–F1600 |
| Pressure rating | 22 bar |
Product description
Silica does not solve every separation. For highly polar, water-soluble, ionic or chiral compounds, normal phase falls short, and the sample is either not retained on the column at all or cannot be recovered. This is where puriFlash reversed phase and functionalized flash columns come in. With the same column body and formats, they make it possible to change the chemistry of the separation.
Interchim offers more than thirty-five selectivities in its flash range. This page brings together the non-silica phases; for normal phase, see the silica flash columns.
Reversed phase flash column phase groups
Reversed phase (C18)
C18-HP is a general-purpose reversed phase column. With its wide pH range (1–10), C18-XS is used for basic compounds and high-pH methods. C18-AQ and RP-AQ operate in nearly 100 percent aqueous mobile phase without phase collapse and are suitable for retaining highly polar compounds in reversed phase.
Polar and normal phase alternatives
CN, Diol and NH2 phases present a less active surface than silica. They are preferred for sensitive compounds that degrade on or cannot be recovered from silica, as well as for sugars and polar heterocycles. The NH2 phase can also be used for HILIC-type separations.
Ion exchange and mixed mode
SCX (strong cation) and SAX (strong anion) phases retain charged compounds; they are used for purifying amines, acids and zwitterionic compounds and as a catch-and-release step. The MM1 mixed-mode phase (reversed phase and SCX) combines both mechanisms in a single column.
Polymer, alumina and chiral
The Polymer X phase (PSDVB) is stable across pH 1–13 and operates under strongly acidic or basic conditions that silica cannot withstand. Neutral and basic alumina are alternatives to silica for acid-sensitive compounds. The IA, IC, ID and OD-I chiral flash columns, with immobilized polysaccharide phases, enable preparative-scale separation of enantiomers.
Technical evaluation
The phases are offered in particle sizes from 15 µm to 100 µm; options vary by phase. The columns share the same body, connections and pressure rating (22 bar) as the silica columns, so they are used on the same instrument with the same method infrastructure. The chiral phases are 20 µm and are available in formats from F0004 to F0220, depending on the phase.
Pore size, surface area and pH range are taken from Interchim catalogs and should be confirmed against the current data sheet for the phase and format to be ordered.
Because reversed phase work uses an aqueous mobile phase, drying the collected fractions takes longer; the parallel evaporator puriFlash XS-Vap can be used for this step. The columns work with flash chromatography systems such as the puriFlash 5.050.
Selection criteria
To choose the right phase, a preliminary trial by TLC or analytical HPLC is recommended. A phase and format recommendation is prepared based on the structure, solubility and target purity of the compound. For large molecules such as peptides and oligonucleotides, the wide-pore puriFlash BIO columns are more suitable.
Technical specifications
| C18-HP | 100 Å, 300 m²/g; 15, 30, 50 µm; pH 1.5–7.5 |
|---|---|
| C18-XS | 100 Å, 300 m²/g; 15, 30 µm; pH 1–10 |
| C18-AQ | 100 Å, 300 m²/g; 15, 30 µm; pH 2–7.5 |
| RP-AQ | 60 Å, 500 m²/g; 15, 30 µm; pH 2–7.5 |
| CN | 60 Å, 500 m²/g; 15, 50 µm |
| Diol | 60 Å, 500 m²/g; 15, 30, 50 µm |
| NH2 | 100 Å, 300 m²/g; 15, 30, 50 µm |
| SCX / SAX | 50 µm; 0.3 meq/g capacity |
| MM1 (reversed phase + SCX) | 100 Å, 400 m²/g; 50 µm |
| Polymer X (PSDVB) | 100 Å, 800 m²/g; 40 µm; pH 1–13 |
| Alumina N / B | 60 Å, 200 m²/g; 32–63 µm; pH 1–12 |
| Chiral | IA, IC, ID, OD-I; 20 µm |
| Formats | F0004–F1600 (depending on phase) |
| Pressure rating | 22 bar / 319 psi |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
Can reversed phase flash columns be reused?
With appropriate washing and conditioning, C18 columns can generally be used more than once. Reuse depends on the cleanliness of the sample and on compounds remaining from the previous run; single use is recommended for pharmaceutical and purity-critical work.
How is the appropriate phase determined?
The polarity and charge of the compound are decisive. C18-AQ or Diol are considered for polar compounds that are retained too strongly on silica, SCX or SAX for charged compounds, and chiral phases for enantiomers.
From the same category

puriFlash Columns and Consumables
Flash columns in more than 35 selectivities, dry-load cartridges and injection consumables.

puriFlash Silica Flash Columns
Prepacked flash columns with SI-HP, SI-HC and standard silica packing, from 4 g to 1.6 kg; compatible with any flash system.

puriFlash BIO Peptide and Biomolecule Columns
Reversed phase flash and preparative columns with 100, 200 and 300 Å pores; for synthetic peptide and biomolecule purification.

Preparative HPLC Columns (puriFlash PREP and Uptisphere)
Stainless steel preparative HPLC columns with 5, 10 and 15 µm packing, from 4.6 mm to 60 mm internal diameter, plus high-pressure dry-load.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote