DLAB
BENCHTOP Single-Parameter Benchtop pH Meter
The BENCHTOP benchtop pH meter family consists of single-parameter instruments that measure pH, conductivity or dissolved oxygen with high accuracy on the laboratory bench. The classic series (DPH100, DEC100, DDO100) offers a simple interface; the touchscreen series (DPH100T, DEC100T, DDO100T) adds ±0.002 pH accuracy, calibration with up to 5 points and memory for 5000 measurements.
Request a quote| Models | pH, conductivity or dissolved oxygen |
|---|---|
| pH accuracy | ±0.01 pH (classic), ±0.002 pH (touchscreen) |
| pH calibration | Up to 3 points (classic) or 5 points (touchscreen) |
| Memory | 450 readings (classic), 5000 readings/parameter (touchscreen) |
| Protection class | IP54 |
Product description
The benchtop pH meter is the most frequently used measuring instrument in the laboratory, from buffer preparation to sample analysis. The BENCHTOP series consists of models that each focus on a single parameter: DPH for pH and ORP, DEC for the conductivity group and DDO for dissolved oxygen.
The classic series speeds up routine measurements with a white backlit display, automatic calibration and a stable reading indicator. The touchscreen series, with an interface that guides users through graphics and text, timed data logging and PC connectivity, is intended for laboratories that require traceability.
The kits come with an electrode, calibration solutions, a flexible electrode holder and a power adapter. The touchscreen series also includes a temperature probe and a magnetic stirrer.
Model comparison
| Model | Parameter | Accuracy | Calibration | Data transfer |
|---|---|---|---|---|
| DPH100 | pH, ORP, temperature | ±0.01 pH | 1–3 points | USB flash drive, printer |
| DEC100 | Conductivity, TDS, salinity, resistivity | ±1.0% of full scale | 1 point | USB flash drive, printer |
| DDO100 | Dissolved oxygen, temperature | ±0.30 mg/L | Automatic | USB flash drive, printer |
| DPH100T | pH, ORP, temperature | ±0.002 pH | 1–5 points | USB flash drive, PC, printer |
| DEC100T | Conductivity, TDS, salinity, resistivity | ±0.5% of full scale | 1 point | USB flash drive, PC, printer |
| DDO100T | Dissolved oxygen, temperature | ±0.30 mg/L | Automatic | USB flash drive, PC, printer |
The classic DPH100 measures in the range of -2.00 to 20.00 pH and the touchscreen DPH100T in the range of -2.000 to 20.000 pH. The DEC100T reaches up to 2000 mS/cm with a K=10 cell; the upper limit of the classic DEC100 is 200 mS/cm.
Applications
- Sample and buffer pH measurement in quality control laboratories
- Conductivity monitoring of pure water and ultrapure water (DEC models)
- Dissolved oxygen monitoring in fermentation and biological studies (DDO models)
- Solution preparation and verification in chemistry laboratories
The accuracy of pH measurement depends largely on the electrode. For selecting the body and connection suited to the sample type, see pH electrodes, and for ORP measurement, ORP and reference electrodes.
Recommendations for accurate measurement
Calibration and measurement should be performed at the same temperature, or automatic temperature compensation should be kept on. The electrode is rinsed with pure water between samples; the glass membrane is dried by gently blotting with a clean tissue, without rubbing.
- Buffer solutions are not left open and are not reused
- The reading is taken after the instrument's stability indicator appears
- If the electrode slope is low, cleaning or replacement is considered
Benchtop pH meter selection criteria
If ±0.01 pH accuracy and 3-point calibration are sufficient for routine measurements, the classic series is an economical choice. If work is carried out over a wide pH range and 5-point calibration and data transfer to a computer are required, the touchscreen series should be preferred.
In conductivity measurement, the cell constant determines the measuring range; this topic is explained in detail on the benchtop conductivity meters page. If more than one parameter is required on the same instrument, the multi-parameter BENCHTOP meters should be considered. All options are listed in the pH and electrochemistry category.
Technical specifications
| pH range | -2.00 to 20.00 pH (classic); -2.000 to 20.000 pH (touchscreen) |
|---|---|
| pH accuracy | ±0.01 pH (classic); ±0.002 pH (touchscreen) |
| pH calibration | 1–3 points (classic); 1–5 points (touchscreen) |
| ORP range | -1999.9 to +1999.9 mV |
| Temperature | -9.9 to 130.0 °C (classic); 0.0–100.0 °C (touchscreen); ±0.2 °C |
| Conductivity range | 0–200 mS/cm (DEC100); 0–2000 mS/cm (DEC100T, K=10) |
| Conductivity accuracy | ±1.0% of full scale (DEC100); ±0.5% (DEC100T) |
| Dissolved oxygen | 0.00–20.00 mg/L, ±0.30 mg/L; saturation 0–200% |
| Oxygen compensation | Pressure 0–200 kPa and temperature automatic; salinity 0–45 ppt manual |
| Memory | 450 readings (classic); 5000 readings/parameter (touchscreen) |
| Data transfer | USB flash drive and printer; PC connection on the touchscreen series |
| Power | DC 12 V adapter |
| Protection class | IP54 |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
What is the main difference between the classic and touchscreen BENCHTOP?
The touchscreen series offers ±0.002 pH accuracy, calibration with up to 5 points, memory for 5000 readings per parameter and PC connectivity. The classic series, with ±0.01 pH accuracy, 3-point calibration and memory for 450 readings, is sufficient for routine work.
How often should a pH meter be calibrated?
Under heavy use, calibration is recommended at the start of each measuring day. Calibration should be performed with at least two buffers covering the measuring range; as the electrode slope decreases, cleaning or replacement of the electrode should be considered.
Which accessories are included in the kit?
The classic kit includes an electrode, calibration solutions, a power adapter and a flexible electrode holder. The touchscreen kit additionally includes a temperature probe, a PC cable and a magnetic stirrer.
From the same category

BENCHTOP Multi-Parameter Benchtop Meter
Classic and touchscreen BENCHTOP meters that measure pH, conductivity and dissolved oxygen in a single instrument.

Benchtop Conductivity Meters
Benchtop instruments that measure conductivity, TDS, salinity and resistivity in the laboratory, with cell options suitable for everything from ultrapure water to concentrated solutions.

Reference and ORP Electrodes
Reference electrodes for half-cell measurements; ORP electrodes with platinum, gold and silver rings.

pH Electrodes
Glass- and plastic-body pH electrodes selected according to sample type; more than 40 models.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote