BENCHTOP Multi-Parameter Benchtop Meter
The multi-parameter benchtop meter measures pH, conductivity and dissolved oxygen on the same instrument, reducing the need for several meters in the laboratory. In the BENCHTOP series, the DPC100 measures pH and conductivity, the DPD100 pH and oxygen, the DCD100 conductivity and oxygen, and the DPCD100 all three parameters together; each model has a touchscreen T version.
Request a quote| Parameter combinations | pH + conductivity, pH + oxygen, conductivity + oxygen, all three |
|---|---|
| pH accuracy | ±0.01 pH (classic), ±0.002 pH (touchscreen) |
| Conductivity accuracy | ±1.0% (classic), ±0.5% (touchscreen) of full scale |
| Dissolved oxygen | 0.00–20.00 mg/L, ±0.30 mg/L |
| Protection class | IP54 |
Product description
In water analysis, quality control and biological studies, conductivity or dissolved oxygen is frequently measured together with pH on the same sample. The multi-parameter benchtop meter combines these measurements on a single display; the electrodes are connected to separate channels and each parameter operates with its own calibration.
The classic series (DPC100, DPD100, DCD100, DPCD100) has a simple interface and memory for 450 readings. In the touchscreen series (DPC100T, DPD100T, DCD100T, DPCD100T), accuracy increases, pH calibration extends to 5 points and 5000 readings are stored per parameter; data can be transferred to a computer.
The kits come with electrodes suited to the measured parameters, buffer and standard solutions, a flexible electrode holder and a power adapter.
Model comparison
| Model (classic / touchscreen) | pH and ORP | Conductivity group | Dissolved oxygen |
|---|---|---|---|
| DPC100 / DPC100T | Yes | Yes | - |
| DPD100 / DPD100T | Yes | - | Yes |
| DCD100 / DCD100T | - | Yes | Yes |
| DPCD100 / DPCD100T | Yes | Yes | Yes |
The conductivity group covers conductivity, TDS, salinity and resistivity values. The upper conductivity limit is 200 mS/cm on the classic models and 2000 mS/cm with a K=10 cell on the touchscreen models. Dissolved oxygen is measured on all models in the range of 0.00–20.00 mg/L with an accuracy of ±0.30 mg/L.
Applications
- Joint reporting of pH and conductivity in laboratory water analysis
- Monitoring of pH and oxygen in fermentation and culture media
- Conductivity and oxygen monitoring in industrial water and process water control
- Multi-parameter water quality assessment in environmental laboratories
If resistivity and conductivity are to be monitored at the outlet of a pure water system, the meter should be considered together with Type 1 ultrapure water systems.
Recommendations for accurate measurement
In multi-parameter measurement, the electrodes are placed in the sample at the same depth without touching each other. Since the conductivity cell can be affected by the filling solution of the pH electrode, the measurement sequence and electrode positions should be kept constant.
- Each parameter is calibrated separately with its own standard solution
- For oxygen measurement, the sample is stirred gently without creating air bubbles
- For pure water measurements, conductivity is read in a closed vessel
Electrode maintenance differs for each parameter: the pH electrode is stored in storage solution, the conductivity cell clean and dry, and the oxygen sensor with its membrane protected. This distinction directly affects electrode life on multi-channel instruments.
Multi-parameter benchtop meter selection criteria
First, the parameters that need to be measured together on the same sample are determined; unnecessary channels increase cost and the electrode maintenance workload. If only pH is to be measured, the single-parameter benchtop pH meter is more suitable.
In regulated laboratories, the touchscreen series stands out because data transfer and calibration records are required. For electrode and sensor selection, see the pH electrodes, benchtop conductivity meters and dissolved oxygen sensors pages. For the same combinations in the field, portable multi-parameter meters are available.
Technical specifications
| pH range | -2.00 to 20.00 pH (classic); -2.000 to 20.000 pH (touchscreen) |
|---|---|
| pH accuracy | ±0.01 pH (classic); ±0.002 pH (touchscreen) |
| pH calibration | 1–3 points (classic); 1–5 points (touchscreen) |
| ORP accuracy | ±0.1% of full scale (classic); ±0.03% (touchscreen) |
| Conductivity range | 0–200 mS/cm (classic); 0–2000 mS/cm, K=10 (touchscreen) |
| TDS / resistivity / salinity | 0–100.0 g/L / 5 Ω·cm–100.0 MΩ·cm / 0–100 ppt |
| Conductivity accuracy | ±1.0% of full scale (classic); ±0.5% (touchscreen) |
| Conductivity temperature compensation | 0.0–50.0 °C |
| Dissolved oxygen | 0.00–20.00 mg/L, ±0.30 mg/L |
| Temperature accuracy | ±0.2 °C |
| Memory | 450 readings (classic); 5000 readings/parameter (touchscreen) |
| Data transfer | USB flash drive and printer; computer on the touchscreen series |
| Power | DC 12 V adapter |
| Protection class | IP54 |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
Are the parameters measured simultaneously on a multi-parameter meter?
Since the electrodes are connected to separate channels, the parameters can be read together on the same sample. Calibration of each parameter, however, is performed separately with its own standard solution.
Which combination is suitable for water analysis?
For routine water analysis, the DPC100 or DPC100T, which measures pH and conductivity together, is sufficient. If oxygen is also to be reported, the three-parameter DPCD100 or DPCD100T should be selected.
Does the classic model have a computer connection?
The classic series exports data via USB flash drive or a wireless printer. Direct connection to a computer is available on the touchscreen series.
From the same category

BENCHTOP Single-Parameter Benchtop pH Meter
Classic and touchscreen BENCHTOP meters; single-parameter models for pH, conductivity or dissolved oxygen.

Benchtop Conductivity Meters
Benchtop instruments that measure conductivity, TDS, salinity and resistivity in the laboratory, with cell options suitable for everything from ultrapure water to concentrated solutions.

Reference and ORP Electrodes
Reference electrodes for half-cell measurements; ORP electrodes with platinum, gold and silver rings.

pH Electrodes
Glass- and plastic-body pH electrodes selected according to sample type; more than 40 models.