DUKO LifeDUKO Life
DLAB portable pH and multiparameter meter

DLAB

Portable pH and Multiparameter Meters

Portable pH meters and multiparameter meters are instruments with a 3.5-inch color display and a rechargeable lithium battery, intended for measurements carried between the field and the laboratory. The single-parameter series includes pH, ORP, conductivity and two types of dissolved oxygen models; the multiparameter series includes combinations that measure pH, conductivity and oxygen together.

Request a quote
pH range and accuracy-2.000 to 20.000 pH; ±0.002 pH
Conductivity range0–2000 mS/cm (with K=10 cell)
Dissolved oxygen0–20 mg/L (polarographic), 0–50 mg/L (optical)
Data loggingUp to 3000 groups
Protection and powerIP57; rechargeable lithium battery, Type-C

Product description

Portable meters offer higher accuracy and a wider measuring range than pocket instruments; the electrode is separate from the body and connected by cable. This design makes it possible to work with different probes depending on the application.

The single-parameter series includes DPH10 (pH and ORP), DORP10 (ORP), DEC10 (conductivity, TDS, salinity, resistivity), DDO10 (polarographic dissolved oxygen) and DDOPRO10 (optical dissolved oxygen). In the multiparameter series, DPC10 measures pH and conductivity, DPD10 pH and oxygen, DCD10 conductivity and oxygen, and DPCD10 measures pH, conductivity and oxygen together.

The instruments come with a 3.5-inch color TFT display, timed data logging and memory for up to 3000 groups. Charging is via a Type-C connection; the housing is rated IP57.

Model comparison

ModelMeasured parametersSeries
DPH10pH, mV (ORP), temperatureSingle-parameter
DORP10ORP, temperatureSingle-parameter
DEC10Conductivity, TDS, salinity, resistivity, temperatureSingle-parameter
DDO10Dissolved oxygen (polarographic), temperatureSingle-parameter
DDOPRO10Dissolved oxygen (optical), temperatureSingle-parameter
DPC10pH, ORP, conductivity groupMultiparameter
DPD10pH, ORP, dissolved oxygenMultiparameter
DCD10Conductivity group, dissolved oxygenMultiparameter
DPCD10pH, ORP, conductivity group, dissolved oxygenMultiparameter

pH accuracy is ±0.002 pH, conductivity accuracy is ±0.5% of full scale, and polarographic oxygen accuracy is ±0.30 mg/L. For oxygen measurement, pressure (0–200 kPa) and temperature (0–50 °C) compensation are automatic, while salinity compensation (0–45 ppt) is manual.

Applications

  • Environmental monitoring and field water analysis
  • Oxygen and pH monitoring in aquaculture
  • Control of fermentation and culture media
  • Comparative measurement of process points at treatment plants

For fixed use in the laboratory, benchtop multiparameter meters that measure the same parameters can also be considered.

Maintenance and use recommendations

On the polarographic oxygen sensor, the membrane and electrolyte are renewed at regular intervals; the sensor must be allowed to polarize before measurement. The pH electrode is kept in storage solution between uses.

In conductivity mode, cell constant calibration and standard solution calibration are supported. Selecting a standard close to the measuring range improves the reliability of results for low-conductivity samples.

Portable pH meter selection criteria

Selection is made first according to the parameter combination. Single-parameter models suit field teams monitoring a single variable, while multiparameter models suit environmental studies in which several parameters must be recorded together on the same sample.

For dissolved oxygen, the polarographic sensor is economical but requires polarization before measurement and membrane maintenance. The optical sensor offers a wider range (0–50 mg/L) and reduces maintenance requirements. For replacement probes, see the pH electrodes, ORP electrodes and dissolved oxygen sensors pages. For a lighter field solution, pocket testers are suitable.

Technical specifications

pH range-2.000 to 20.000 pH
pH resolution and accuracy0.1 / 0.01 / 0.001; ±0.002 pH ± 1 digit
pH calibration1, 2 or 3 points, automatic
ORP range and accuracy-1999.9 to +1999.9 mV; ±0.03% of full scale
Conductivity range0–2000 mS/cm (K=10); matched test range 0–200 mS/cm
TDS / resistivity / salinity0–100.0 g/L / 5.000 Ω·cm–100.0 MΩ·cm / 0–100 ppt
Conductivity accuracy±0.5% of full scale ± 1 digit
Dissolved oxygenPolarographic 0.00–20.00 mg/L (±0.30 mg/L); optical 0.00–50.00 mg/L
Oxygen saturation0.0–200.0%
Temperature0.0–100.0 °C, ±0.2 °C
Display3.5-inch color TFT
Data logging3000 groups, timed logging
PowerRechargeable lithium battery, Type-C charging
Protection ratingIP57

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between polarographic and optical oxygen sensors?

The polarographic sensor works by an electrochemical reaction; it requires a polarization time before measurement and regular membrane and electrolyte maintenance. The optical sensor is based on the luminescence principle, needs no warm-up time and requires less maintenance; on the DDOPRO10 it offers a 0–50 mg/L range.

Should a multiparameter meter or two separate instruments be preferred?

If parameters are to be recorded together on the same sample, a multiparameter meter provides a single display and a single data file. If parameters are measured at different points by different people, separate instruments simplify the workflow.

Is the instrument damaged if it falls into water?

The housing is rated IP57 and protected against brief immersion in water. Nevertheless, keeping the connector socket dry and cleaning it after use is recommended.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote