DUKO LifeDUKO Life
Konica Minolta CM-25cG spectrophotometer with circumferential illumination

Konica Minolta

CM-25cG Color and Gloss Spectrophotometer

CM-25cG is a spectrophotometer with circumferential illumination that measures color and 60° gloss simultaneously in 45°c:0° geometry. Because 45°:0° geometry gives results close to the way the eye perceives a surface, it is preferred for quality control that is consistent with visual assessment.

Request a quote
Color geometry45°c:0° (circumferential illumination)
Gloss60°, 0–200 GU
Spectral range360–740 nm, 10 nm pitch
Measurement apertureMAV Ø8 mm / SAV Ø3 mm
Inter-instrument agreementΔE*ab 0.15

Product description

CM-25cG is a portable spectrophotometer that measures color in 45°c:0° geometry and provides a 60° gloss value in the same measurement. Circumferential illumination reduces deviations caused by rotating the sample on surfaces with directional texture.

45°:0° geometry does not include light specularly reflected from the surface in the measurement; the result is close to the conditions under which the human eye evaluates a surface. Taking the gloss value from the same point makes it easier to determine whether a color difference is caused by surface gloss or by the pigment.

The instrument works with Ø8 mm (MAV) and Ø3 mm (SAV) measurement apertures; the display supports a vertical operating mode.

CM-25cG is the renewed version of the CM-2500c model. A 60° gloss sensor has been added to the 45°:0° color geometry, combining color and gloss in a single instrument.

Applications

  • Color and gloss matching of automotive interior parts
  • Color compliance of high-visibility workwear (EN 471)
  • Quality control of paint and coating surfaces consistent with visual assessment
  • Measurement of textured and directional surfaces
  • Color control in textiles, especially fluorescent (neon) colored products

Key features of the spectrophotometer with circumferential illumination

Color measurement

A dual 40-element detector measures in the 360–740 nm range at 10 nm pitch. Repeatability is ΔE*ab 0.04 and inter-instrument agreement is ΔE*ab 0.15. Measurement time is approximately 1 second and the minimum interval is approximately 2 seconds.

Gloss measurement

60° gloss is measured with a white LED source over a range of 0–200 GU with 0.01 GU resolution. It complies with ISO 2813, ASTM D523, ASTM D2457, DIN 67530 and JIS Z 8741. Repeatability is 0.1 GU in the 0–10 GU range and 0.2 GU in the 10–100 GU range.

Data

The instrument stores 2,500 standards and 7,500 samples. USB 2.0 is standard and Bluetooth is optional. Approximately 3,000 measurements can be taken with the Li-ion battery.

On textured plastics, fabrics and directional surfaces, the measurement result can change when the sample is rotated relative to the instrument. Circumferential illumination reduces this directional dependence; nevertheless, for repeatable results the sample is placed in the same orientation for each measurement and the measurement point is recorded.

Selection criteria

If d:8° measurement including the specular component (SCI) is required, the CM-26dG offers the same gloss function with sphere geometry. For metallic and effect pigment surfaces, the CM-M6 should be considered, and for gloss measurement only, the Multi Gloss 268A.

Measurements taken with 45°:0° and d:8° geometries cannot be converted directly into one another. The geometry with which existing color standards are defined should be checked before selecting an instrument.

Recording, tolerance evaluation and reporting of measurement data can be performed with SpectraMagic NX2.

The general framework of color and gloss measurement is summarized on the laboratory technologies page; other models are listed under color and gloss measuring instruments. Color values are calculated according to the illuminant and observer conditions defined by the CIE colorimetry principles.

Technical specifications

Color geometry45°c:0°; ISO 7724/1, CIE No.15, ASTM E179/E1164, DIN 5033-7, JIS Z 8722 a
DetectorDual 40-element silicon photodiode array
Spectral range360–740 nm, 10 nm pitch
Reflectance range0–175%
Light sourceXenon lamp (color), white LED (gloss)
Color measurement areaMAV Ø8 mm, SAV Ø3 mm
Gloss60°, 0–200 GU, 0.01 GU resolution
Gloss standardsISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z 8741, JIS K 5600
Gloss measurement areaMAV Ø10 mm, SAV Ø3 mm
Measurement timeApprox. 1 s; minimum interval approx. 2 s
RepeatabilityΔE*ab 0.04; gloss 0.1 GU (0–10 GU), 0.2 GU (10–100 GU)
Inter-instrument agreementΔE*ab 0.15; gloss ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU)
Observer2° and 10°; LED illuminants included
Memory2,500 standards, 7,500 samples
ConnectivityUSB 2.0; Bluetooth optional
PowerLi-ion battery, approx. 3,000 measurements
Dimensions / weight81 × 81 × 224 mm; approx. 600 g

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

When is 45°:0° geometry preferred?

45°:0° geometry is preferred when the measurement result should be close to visual assessment. Because this geometry excludes specular reflection, differences in surface gloss are reflected in the color value.

What is the advantage of circumferential illumination?

Light reaching the sample at a 45° angle from all directions reduces position-dependent deviations on textured or directional surfaces.

What is the main difference between CM-25cG and CM-26dG?

Both instruments measure 60° gloss. CM-25cG measures color in 45°c:0° geometry, while CM-26dG measures SCI and SCE in d:8° geometry.

Which model replaced the CM-2500c?

The CM-2500c has been replaced by the CM-25cG. Using the same 45°:0° geometry, the model additionally provides a 60° gloss value in the same measurement.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote