Konica Minolta Multi Gloss 268A three-angle gloss meter

Konica Minolta

Multi Gloss 268A Three-Angle Gloss Meter

Multi Gloss 268A is a portable three-angle gloss meter whose 20°, 60° and 85° geometries cover every gloss level, from matte to high-gloss surfaces. Broad standards compliance and AA battery operation make it practical for quality control both in the laboratory and in the field.

Request a quote
Measurement angles20° · 60° · 85°
Measurement range20°: 0–2000 · 60°: 0–1000 · 85°: 0–160 GU
Repeatability0.2 GU (below 100 GU)
Memory999 measurements
Weight400 g

Product description

Multi Gloss 268A is a general-purpose gloss meter that combines three measurement angles in a single housing. The 20° angle is used for high-gloss, the 60° angle for medium-gloss and the 85° angle for matte surfaces. Laboratories that inspect product groups with different gloss levels can cover the entire range with a single instrument.

A separate measurement area is defined for each angle: 10×10 mm for 20°, 9×15 mm for 60° and 5×38 mm for 85°. Measurement takes 0.5 seconds per angle. The instrument complies with the gloss geometries of ISO, ASTM, DIN, BS and JIS standards.

Measurements at all three angles are taken at the same position and the results are displayed together. Statistics, pass/fail and continuous measurement modes simplify uniformity checks on large surfaces; an automatic diagnostic function prevents faulty measurements.

Applications

  • Batch approval in paint, varnish and coating production
  • Gloss control of plastics, furniture surfaces and building materials
  • Quality control departments measuring both matte and high-gloss products in the same laboratory
  • Verification of gloss specifications between suppliers and customers
  • Gloss measurement on mirror-like metal surfaces

Technical evaluation

Resolution is 0.1 GU below 100 GU and 1 GU at 100 GU and above. Repeatability is 0.2 GU below 100 GU and 0.2% of reading above. Inter-instrument agreement is 0.5 GU below 100 GU and 0.5% of reading above.

The instrument performs approximately 4,000 measurements on an AA battery and stores 999 measurements. Data is transferred via USB 2.0 and can be evaluated with Smart-Lab Gloss software. Operating temperature is 15-40 °C.

The angle is selected according to the gloss level of the surface being measured: the first measurement is taken at 60°; if the value is high, the 20° angle is used, and if it is low, the 85° angle. Having all three angles in one instrument allows product groups with different gloss levels to be monitored in the same laboratory. However, the specification should state which angle is the reference, because values obtained at different angles cannot be converted into one another.

Selection criteria for a three-angle gloss meter

If appearance parameters such as haze, DOI and RIQ are also required, the Rhopoint IQ-S should be preferred. If only medium-gloss measurements are needed, the single-angle Uni Gloss 60A or Novo-Gloss 60 KM is more economical. If color and gloss are to be measured with the same instrument, the CM-26dG can be considered.

The general framework of color and gloss measurement is summarized on the laboratory technologies page; other models are listed under color and gloss measuring instruments. The method for specular gloss measurement is defined in the ASTM D523 standard.

Technical specifications

Measurement angles and areas20°: 10×10 mm · 60°: 9×15 mm · 85°: 5×38 mm
Measurement range20°: 0–2000 GU · 60°: 0–1000 GU · 85°: 0–160 GU
ResolutionBelow 100 GU: 0.1 GU · 100 GU and above: 1 GU
RepeatabilityBelow 100 GU: 0.2 GU · 100 GU and above: 0.2%
Inter-instrument agreementBelow 100 GU: 0.5 GU · 100 GU and above: 0.5%
StandardsISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z8741, BS 3900, BS 6161-12
Measurement time0.5 seconds per angle
Memory999 measurements
InterfaceUSB 2.0; Smart-Lab Gloss software
PowerAA battery, approx. 4,000 measurements
Operating temperature15–40 °C
Dimensions155 × 73 × 48 mm
Weight400 g

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between the 20°, 60° and 85° measurement angles?

The 60° angle is the reference geometry for medium-gloss surfaces and serves as the starting point for most measurements. On high-gloss surfaces reading above 70 GU at 60°, 20° is preferred to increase differentiation, while 85° is preferred for matte surfaces below 10 GU. This classification is consistent with the approach in ISO 2813 and ASTM D523.

How often should a gloss meter be calibrated?

The instrument is checked against its own calibration standard before each measurement session. Periodic verification of the calibration standard and the instrument should be performed by an authorized service provider at the interval defined in the quality system.

In what unit are measurement results reported?

Gloss is reported in GU (gloss units). The value expresses the amount of light reflected from the surface at a given angle relative to a polished black glass reference standard.