DUKO LifeDUKO Life
Rhopoint IQ-S gloss and haze meter

Rhopoint Instruments

IQ-S 20/60/85 Gloss and Appearance Meter

The Rhopoint IQ-S is a portable gloss and haze meter that combines three-angle gloss measurement with reflection haze, distinctness of image (DOI), reflected image quality (RIQ) and Rspec data. On high-gloss paints and coatings, it quantifies appearance differences that the GU value alone cannot explain.

Request a quote
Measurement angles20° · 60° · 85°
Additional parametersHaze, DOI, RIQ, Rspec
Measurement range20°: 0–2000 GU · 60°: 0–1000 GU
ConnectivityUSB and Bluetooth
Weight390 g

Product description

The Rhopoint IQ-S is a three-angle gloss meter measuring with 20°, 60° and 85° geometries. Unlike a conventional gloss meter, it analyzes not only the amount but also the distribution of light reflected from the surface. As a result, the appearance difference between two surfaces with the same GU value can be distinguished by additional parameters such as haze, DOI and RIQ.

On high-gloss paints, a hazy or milky reflection is usually a sign of surface defects related to dispersion, curing or polishing. Reflection haze measurement quantifies this condition following the ASTM E430 and ASTM D4039 approach. DOI and RIQ evaluate the sharpness of the reflected image, revealing the visual effect of structural defects such as orange peel and waviness.

Applications

  • Gloss, haze and image clarity control of automotive exterior paints
  • Batch approval and formulation development in paint and coating production
  • Monitoring gloss and appearance differences caused by mold surfaces on plastic parts
  • Process-level investigation of defect sources on polished and high-gloss surfaces

Key features

Full range at three angles

Measurements are made up to 2000 GU at 20°, up to 1000 GU at 60° and up to 199 GU at 85°. Resolution is 0.1 GU. Measurement conforms to ISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530 and JIS Z8741.

Appearance parameters

Haze is reported over 0–500 Log HU, DOI and RIQ over 0–100, and Rspec over 0–2000. Because these parameters are obtained during the same measurement, no separate instrument is required.

Data and power

The internal 8 MB memory stores 2,000 readings. Data can be transferred directly to Excel via USB or Bluetooth. The Li-ion battery provides more than 17 hours of operation and more than 20,000 readings per charge.

Gloss and haze meter selection criteria

If measurements are to be made at 20° only on curved or narrow parts, the IQ FLEX 20-S with remote measuring head is more suitable. For routine quality control where haze and DOI are not required, the three-angle Multi Gloss 268A is an economical alternative. If color and 60° gloss must be captured in the same measurement, the CM-25cG should be considered.

For detailed analysis of larger-scale surface structures such as orange peel and waviness, the imaging-based Rhopoint TAMS appearance meter is recommended.

Different geometry and aperture options can be compared in the color and gloss measuring instruments catalog. Haze and image clarity measurement on high-gloss surfaces is described in ASTM E430.

Technical specifications

Measurement angles20°, 60°, 85°
20° range0–2000 GU
60° range0–1000 GU
85° range0–199 GU
Resolution0.1 GU
Repeatability (60°)0–10 GU: 0.1 GU · 10–100 GU: 0.2 GU · above 100 GU: 0.2%
Reproducibility (60°)0–10 GU: 0.2 GU · 10–100 GU: 0.5 GU · above 100 GU: 0.5%
Measurement area20°: 6×6.4 mm · 60°: 6×12 mm · 85°: 4.4×44 mm
Haze0–500 Log HU; repeatability 1, reproducibility 10 (ASTM E430, ASTM D4039)
DOI / RIQ0–100; repeatability 0.2, reproducibility 0.5
Rspec0–2000; repeatability 0.2%, reproducibility 0.5%
StandardsISO 2813, ISO 7668, ASTM D523, ASTM D2457, DIN 67530, JIS Z8741
Memory8 MB, 2,000 readings
ConnectivityUSB and Bluetooth, direct transfer to Excel
PowerLi-ion battery; more than 17 hours of operation, more than 20,000 readings per charge
Dimensions140 × 50 × 65 mm
Weight390 g
CalibrationISO 17025 UKAS-accredited certificate

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the difference between the 20°, 60° and 85° measurement angles?

The 60° angle is the reference geometry for medium-gloss surfaces and is used as the starting point for most measurements. On high-gloss surfaces reading above 70 GU at 60°, 20° is preferred to increase differentiation, and on matte surfaces below 10 GU, 85° is preferred. This classification is consistent with the approach in ISO 2813 and ASTM D523.

What does haze (reflection haze) indicate?

Haze is a measure of the milky or cloudy appearance that forms around the reflection on a glossy surface. Two paints with the same gloss value look different to the eye if their haze values differ. This value is used to monitor dispersion, curing and polishing conditions.

What is the difference between DOI and RIQ?

Both parameters evaluate the sharpness of the image reflected on the surface. RIQ is more sensitive than DOI to small differences in sharpness on high-quality surfaces; for this reason, the two are reported together in demanding applications such as automotive.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote