DUKO LifeDUKO Life
Entry-level digital rotational viscometer

Viscosity and Rheology

Entry-Level Rotational Viscometer

The digital rotational viscometer is designed with a springless measuring system for routine viscosity control. It offers unlimited speed selection between 0.3 and 250 rpm, a torque range of 0.05–13 mNm and a measuring range from 200 mPa·s to 240,000,000 mPa·s depending on geometry.

Request a quote
Speed0.3–250 rpm, unlimited selection
Torque0.05–13 mNm (LR: 0.005–0.8 mNm)
Viscosity200–240,000,000 mPa·s (depending on geometry)
Accuracy1% of full scale
Weight6.1 kg

Product description

The entry-level rotational viscometer answers a single question in daily quality control: what is the viscosity of the sample in mPa·s under the specified conditions? It answers this question quickly, repeatably and in a form that can be recorded.

The measuring principle is rotational. The spindle immersed in the sample is rotated at constant speed, the resistance the sample exerts on the spindle is measured as torque and converted to viscosity using the geometry constant. Speed is selected steplessly between 0.3 rpm and 250 rpm; users are not restricted to fixed steps for intermediate values.

In addition to viscosity, the instrument displays shear rate, shear stress and torque percentage. When the sample density is entered, kinematic viscosity is also calculated. For thixotropic samples, a measurement time can be defined, so that the reading is taken after the same time every time and comparable results are obtained.

This model does not include method programming or on-screen flow curve generation. It is the right choice for laboratories that measure and report under a single condition; if rheological characterization is required, a higher class should be chosen.

Common technical platform

All instruments in this class operate on the springless measuring principle. In classic designs with a spiral spring, spring fatigue leads to calibration drift over time; in the springless system, torque is measured directly and this drift is eliminated.

The spindle connection is a bayonet type rather than threaded. The spindle is attached and removed in a single movement; thread wear or cross-threading over time is not an issue. In laboratories that change spindles frequently, this detail reduces the daily workload.

  • Accuracy: 1% of full scale
  • Repeatability: 0.2%
  • Temperature sensor: PT100, -50 °C … +300 °C
  • Display: 7-inch color touchscreen, Turkish-language menu
  • Values shown on the display: viscosity, speed, shear rate, torque, shear stress, time, temperature
  • Power supply: 90–240 VAC, 50/60 Hz

Measuring geometries

In a rotational viscometer, the main factor determining the result is the geometry in contact with the sample. The same instrument covers very different viscosity ranges with different geometries.

  • Standard cylindrical spindles: Measurement in a large container for medium- and high-viscosity products.
  • Low-viscosity geometries: Operate in the low torque range for solvents, resin solutions and liquid foods.
  • Small sample adapter: Temperature-controlled measurement with a jacketed chamber for limited sample quantities.
  • Coaxial cylinder (DIN) geometry: Measurement at a defined shear rate according to DIN 53019 and ISO 3219.
  • Vane geometry: Measurement without disrupting the structure of gels, pastes and suspensions prone to settling.
  • Krebs geometry: Measurement in KU units for the paint industry.
  • Ultra-low viscosity geometry: Measurements down to the order of 1 mPa·s.

Geometry selection determines both the viscosity range and the required sample volume. Once the product type and expected viscosity band are provided, the right set is recommended.

Related standards

Rotational viscosity measurement is reported according to different standards depending on the industry. The instruments can be configured to operate under the measurement conditions defined in the following families of standards.

  • ASTM: D2196 (rotational viscosity), D789 (polyamides), D1084 and D2556 (adhesives), D1417 and D1439 (latex and cellulose derivatives), D4878 (polyols), D6279, D3236, D3794, D4016
  • ISO: 2555, 3219, 1652, 2884-2
  • DIN: 53019, 3219, 2555, 52007-1, 54453
  • EN: 12092, 12802, 15425, 15564, 2555, 3219

The standard to be applied directly determines the measuring geometry and shear rate. When the standard number is specified in the quotation request, the right geometry set is recommended.

Digital rotational viscometer setup and use

The instrument is used on a stand with feet or on a rack-type stand. The height adjustment on the stand fixes the immersion depth of the spindle in the sample; if the immersion depth changes, the result also changes, so the immersion mark must be observed.

A jacketed chamber or circulating bath is added for temperature control. Since viscosity changes exponentially with temperature, a deviation of 1 °C can cause a difference of up to 10% for some products.

Data transfer is via USB. The printer connection works with PCL/5-compatible devices.

The scope of delivery includes a spindle set, stand, user manual, calibration certificate and verification report.

If a temperature probe, Ethernet connection and LIMS integration are required, the LIMS-compatible viscometer is preferred. Other options in the series and basic models are on the rotational and KU viscometer models page, and all instruments are in the viscosity and rheology category. Relative viscosity measurement of paints and varnishes with a disc or sphere rotor at specified speeds is defined in the ISO 2884-2 standard.

Technical specifications

Speed range0.3–250 rpm, stepless
Torque (standard)0.05–13 mNm
Torque (low range)0.005–0.8 mNm
Viscosity200–240,000,000 mPa·s
Low-range viscosity15–22,000,000 mPa·s (down to 1 mPa·s with special geometry)
Accuracy1% of full scale
Repeatability0.2%
TemperaturePT100, -50 °C … +300 °C (optional probe)
Display7-inch color touchscreen
Data outputUSB
DimensionsHead Ø115 × H243 × W138 mm · stand 340 × 305 × 70 mm · shaft 500 mm
Weight6.1 kg
Power supply90–240 VAC, 50/60 Hz

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Which laboratories is this model suitable for?

It is suitable for laboratories performing routine viscosity control under a single measurement condition. It is widely used for incoming and outgoing inspection in paint, adhesive, cosmetics and liquid food production.

Can it plot a flow curve?

No. This model takes single-point measurements; it does not generate flow curves on screen and does not save methods. If curves, yield point and thixotropy calculations are required, a rheometer-class instrument should be chosen.

What is the advantage of the springless design?

In spiral spring viscometers, the spring fatigues over time and calibration drifts. In the springless system, torque is measured directly; this source of drift is eliminated and the instrument delivers more stable results throughout its life.

Which spindle should be selected?

Spindle selection is based on the expected viscosity range. The torque percentage read should remain between 10% and 90%; outside this band, the result is not reliable. The instrument displays the valid viscosity limits for the spindle and speed on screen.

Is the temperature probe standard?

On this model, the temperature probe is optional. For applications where temperature must be reported, the probe or a higher model is recommended.

What is the measurement accuracy?

The accuracy of 1% of full scale and repeatability of 0.2% apply to all instruments. These values should be evaluated together with the selected measuring geometry; the geometry determines the measurable viscosity range.

How is temperature measured?

The PT100 sensor reads the sample temperature between -50 °C and +300 °C. Since viscosity depends strongly on temperature, the measurement report must also include the temperature. A jacketed chamber or circulating bath is used to keep the temperature constant.

Is a Turkish-language menu available?

Yes. The 7-inch color touchscreen offers a multilingual menu including Turkish. Users can be defined with an operator name and a four-digit code; in protected mode, the measurement conditions are locked.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote