DUKO LifeDUKO Life
Konica Minolta CF-300 non-contact spectrophotometer

Konica Minolta

CF-300 Non-Contact High-Speed Spectrophotometer

The CF-300 is a non-contact spectrophotometer that measures the color of small parts and components in approximately 0.1 seconds and can also operate in contact mode when needed. With a 0.75×1 mm measurement area, vertical or horizontal mounting and an RS-232C interface, it can be integrated into automation systems.

Request a quote
Measurement timeApprox. 0.1 s
Measurement areaØ8 mm or 0.75×1 mm
Non-contact distance1.0 mm (0.7 mm with glass mask)
RepeatabilityΔE*ab 0.02
Light sourceHigh-CRI white LED

Product description

The CF-300 is a spectrophotometer developed for rapidly measuring the color of large numbers of small parts on or near the production line. With a measurement time of approximately 0.1 seconds and an interval of 0.2 seconds between measurements, it can reach up to 5 measurements per second.

The distinguishing feature of the instrument is its ability to measure without touching the sample. With the non-contact (NC) target mask, the measurement distance is 1.0 mm; with the glass non-contact mask, it is 0.7 mm. Delicate surfaces, wet coatings or parts that must not be contaminated are thus measured without damage.

With the XUSAV target mask, the measurement area shrinks to as small as 0.75×1 mm, allowing small components such as buttons, connectors and caps to be evaluated individually. The instrument can be mounted in a vertical or horizontal position.

Applications

For the CF-300, the manufacturer highlights automotive interior, pharmaceutical and cosmetics, and apparel applications.

  • Color control of small plastic parts and buttons in automotive interiors
  • Measurement of caps, tablets and small components in pharmaceutical and cosmetic packaging
  • Color matching of buttons, zippers and accessories in apparel
  • Automated inspection stations fed by robots or conveyors
  • Non-contact measurement of wet or delicate surfaces

Technical evaluation

The optical system is built around a Ø152 mm integrating sphere and a white LED with a high color rendering index (CRI). With di:8° / de:8° geometry, it can switch between SCI and SCE; measurements are taken over 400–700 nm at 10 nm pitch.

Repeatability is ΔE*ab 0.02 for MAV/SCI contact measurement, and inter-instrument agreement is ΔE*ab 0.15. The instrument has no display of its own; color systems, indices and color difference formulas are displayed in the separately sold SpectraMagic NX2 software.

USB 2.0 and RS-232C interfaces allow the instrument to work with automation and machine vision systems. A sample holder with base for benchtop use and a camera set for positioning are offered as options.

The operating temperature is limited to 15–30 °C. For installations close to production areas, keeping the ambient temperature within this range should be assessed before installation.

Non-contact spectrophotometer selection criteria

If a wide wavelength range (360–740 nm), UV control and transmittance measurement are required rather than measurement speed, the CM-36dG series or the CM-3700A Plus is more suitable. If handheld small-area measurement outside the laboratory is required, the CM-17d with SAV aperture and camera can be considered.

Other models in the category are listed under color and gloss measuring instruments. Color values are calculated according to the illuminant and observer conditions defined by the CIE colorimetry principles.

Technical specifications

Geometrydi:8° / de:8°, SCI and SCE switchable; JIS Z 8722 condition c, ISO 7724/1
Integrating sphereØ152 mm
DetectorDual 40-element silicon photodiode array, plane diffraction grating
Wavelength range400–700 nm, 10 nm pitch
Measurement range0–175%, resolution 0.01%
Light sourceHigh-CRI white LED
Measurement / illumination areaMAV Ø8/11 mm; XUSAV 0.75×1 / 5×7 mm; illumination Ø34 mm in non-contact measurement
Measurement distanceContact 0.0 mm; non-contact 1.0 mm; glass non-contact mask 0.7 mm
Measurement timeApprox. 0.1 s; minimum interval between measurements approx. 0.2 s
RepeatabilityΔE*ab 0.02 (MAV/SCI, contact)
Inter-instrument agreementΔE*ab 0.15 (MAV/SCI, 12 BCRA Series II tiles)
InterfaceUSB 2.0, RS-232C
SoftwareColor values and indices displayed with SpectraMagic NX2 (sold separately)
PowerAC adapter, 100–240 V, 50/60 Hz
Operating environment15–30 °C, 80% relative humidity or less, non-condensing
Dimensions / weight186 × 202 × 317 mm (height 246 mm with handle); approx. 7.3 kg

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

When is non-contact measurement required?

Wet coatings, surfaces that scratch easily or must not be contaminated, and parts moving on an automated line should be measured without contact. In these cases, the CF-300 measures from a distance of 1.0 mm, or 0.7 mm with the glass mask.

How many measurements can be taken per second?

The measurement time is approximately 0.1 seconds and the shortest interval between measurements is approximately 0.2 seconds. With these values, up to 5 measurements per second can be achieved.

Can the CF-300 be used on a laboratory bench?

Yes. The optional sample holder with base allows the instrument to be used like a conventional benchtop spectrophotometer.

Does the instrument have a display?

No. The CF-300 operates connected to a computer or automation system; measurement results are displayed in SpectraMagic NX2 software or in the system into which it is integrated.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote