DUKO LifeDUKO Life
Konica Minolta CR-410C coffee colorimeter

Konica Minolta

CR-410C Coffee Colorimeter

The CR-410C is a coffee colorimeter built on the CR-410 platform and running coffee-specific software. It measures the color of coffee in various forms, from green beans to roasted and freeze-dried coffee, using the SCAA index.

Request a quote
IndexSCAA coffee color scale
Measurement apertureØ50 mm
Sample formGreen, roasted, freeze-dried
RepeatabilityWithin ΔE*ab 0.07 standard deviation
WeightApprox. 570 g

Product description

Coffee color measurement is the most direct way to keep the roast degree consistent from batch to batch. The CR-410C is based on the CR-410 colorimeter head with its Ø50 mm aperture, with coffee-specific software and a sample fixture added. The instrument firmware includes the Specialty Coffee Association of America (SCAA) coffee color index.

In addition to color values, each measurement provides the color difference from the standard, the roast level (light, medium, medium-dark, dark) and a pass/fail assessment against defined tolerances. The roaster's visual judgment is thus turned into a numerical value that can be documented.

The large measurement area produces a result from the average of a wide area rather than a single point for samples with uneven surfaces such as beans and ground coffee. This improves consistency across repeated measurements of the same sample.

The roast degree is reported in the light, medium, medium-dark and dark classes of the SCAA specialty coffee index. This classification creates a common language between the roastery and the buyer.

Applications

  • Supply and incoming inspection of green coffee beans
  • Tracking the roast profile across batches
  • Quality control of roasted beans and ground coffee
  • Color consistency of freeze-dried (lyophilized) coffee
  • Establishing a common color standard between the roastery and the laboratory

Technical evaluation

The hardware is identical to the CR-410: d:0° wide-area illumination, six silicon photocells and a pulsed xenon lamp. Repeatability on the white plate is within ΔE*ab 0.07 standard deviation, and inter-instrument agreement averaged over 12 BCRA Series II tiles is ΔE*ab 0.8.

A measurement takes 1 second, and the minimum interval between two measurements is 3 seconds. The instrument runs on 4 AAA batteries or an AC adapter and can be used in the field, next to the roaster. 1,000 measurements and 100 target colors are stored in memory.

In coffee color measurement, the result depends directly on how the sample is prepared. Grind size, fill level in the sample container and surface flatness should be kept the same for every measurement; the sample fixture supplied with the instrument is used for this standardization.

Coffee colorimeter selection criteria

If other food products besides coffee are also to be measured, the general-purpose CR-400 / CR-410 without an industry-specific index is a more flexible option. The CR-410T, which uses the same head, for tomato products and the BC-10 Plus for baked goods are industry-specific alternatives.

Other models in the category are listed under color and gloss measuring instruments.

Technical specifications

Base instrumentCR-410 measuring head with coffee software
Optical geometryWide-area illumination, 0° viewing, specular component included
Detector6 silicon photocells
Light sourcePulsed xenon lamp
Measurement / illumination areaØ50 / Ø53 mm
RepeatabilityWithin ΔE*ab 0.07 standard deviation
Inter-instrument agreementΔE*ab 0.8 (average of 12 BCRA Series II tiles)
Observer / illuminantCIE 2° · C, D65
Color dataXYZ, Yxy, L*a*b*, Hunter Lab, L*C*h, CMC, CIE1994, CIE2000, SCAA scale
Measurement time1 s; minimum measurement interval 3 s
Memory1,000 measurements; 100 target colors
InterfaceRS-232
Power4 × AAA batteries or AC adapter; approx. 800 measurements on batteries
Dimensions102 × 244 × 63 mm
WeightApprox. 570 g, including batteries

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What is the SCAA index used for?

The SCAA index converts the color of coffee into a scale commonly accepted in the industry. The roast degree is thus classified as light, medium, medium-dark and dark, and different sites and suppliers can communicate on the same scale.

Which coffee forms can be measured?

The manufacturer states that green beans, roasted beans, and roasted and freeze-dried coffee can be measured. Keeping the sample preparation method constant for each form is recommended.

What is the difference between a colorimeter and a spectrophotometer?

A colorimeter measures tristimulus values directly with three filters approximating the color sensitivity of the human eye; it is a fast and economical solution for color difference control. A spectrophotometer measures reflectance wavelength by wavelength; it is required for tasks such as evaluation under different illuminants, metamerism analysis and color formulation.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote