DUKO LifeDUKO Life
Konica Minolta PaperManager paper measurement software

Konica Minolta

PaperManager Paper and Pulp Measurement Software

PaperManager is paper measurement software developed for the pulp and paper industry that calculates color and optical properties. Together with the CM-3630A spectrophotometer with d:0° geometry, it calculates ISO brightness, CIE whiteness, opacity and color values in accordance with industry standards.

Request a quote
Compatible instrumentCM-3630A spectrophotometer (d:0°)
MeasuredISO brightness, CIE whiteness and tint, opacity, color
StandardsISO 2469, 2470, 2471, 5631, 11475
Operating systemWindows 7, 8 and 10
LicenseDongle-protected

Product description

PaperManager is dedicated software developed for daily quality control measurements in paper and pulp laboratories. It was developed by NoviProfibre, which has long served the paper industry, and is based on the current color measurement standards of the sector.

The software works only with the CM-3630A paper spectrophotometer. When used together with this instrument, which has d:0° measurement geometry, it forms a measurement system fully compliant with paper-industry-specific standards such as ISO 2469 and ISO 2470.

Measurements are stored in a database, and by defining user profiles, separate measurement layouts can be created for different products or production lines. The screen design can be customized by the user, and the software can be operated with a touchscreen.

Applications

  • ISO brightness and CIE whiteness measurement of paper and board
  • Brightness and color monitoring of pulp
  • Opacity and transparency measurement of paper
  • Evaluation of fluorescence effects in products containing optical brightening agents
  • Measuring deinking performance on recycled paper
  • Daily quality control and reporting of production line samples

Key features

Calculations specific to the paper industry

In addition to CIELAB, Hunter Lab, XYZ, Yxy and Rx, Ry and Rz color values, the software calculates CIE whiteness and tint, ISO brightness (R457, TAPPI), opacity, transparency, and light absorption and scattering coefficients. For recycled paper, deinking efficiency is given as a percentage according to the INGEDE method.

UV calibration

UV calibration is performed for CIE whiteness and tint, ISO brightness and spectral profile data. This ensures that measurements on papers containing optical brightening agents are made with a defined UV content.

Supported standards

The software supports the methods for reflectance factor (ISO 2469), ISO brightness (ISO 2470), opacity (ISO 2471), pulp brightness (ISO 3688), color determination under different illuminants (ISO 5631-1, -2, -3), light scattering and absorption coefficients (ISO 9416), CIE whiteness (ISO 11475), indoor whiteness (ISO 11476), as well as ISO 12625-7 and ISO 12625-15 for tissue products.

Selection criteria for paper measurement software

In paper and pulp laboratories, PaperManager should be planned together with the CM-3630A. For general color quality control of non-paper products or with other Konica Minolta instruments, SpectraMagic NX2 is the more suitable software.

The software is licensed via USB dongle and is stated to be compatible with Windows 7, 8 and 10. The operating system of the computer on which it will be installed should be checked before ordering.

Other models in the category are listed under color and gloss measuring instruments. Test methods used in the paper industry are also published by TAPPI.

Technical specifications

Compatible instrumentCM-3630A (d:0° geometry)
DeveloperNoviProfibre
Color valuesCIELAB, Hunter Lab, XYZ, Yxy, Rx / Ry / Rz
Whiteness and brightnessCIE whiteness and tint; ISO brightness R457 (TAPPI)
Optical propertiesOpacity, transparency, light absorption and scattering coefficients
RecyclingINGEDE deinking (IE700, %)
CalibrationUV calibration for CIE whiteness and tint, ISO brightness and spectral profile
ISO standardsISO 2469, 2470, 2471, 3688, 5631-1, 5631-2, 5631-3, 9416, 11475, 11476, 12625-7, 12625-15
Data managementMeasurement storage in a database, user profiles
InterfaceUser-customizable screen, touchscreen support
Operating systemWindows 7, 8 and 10
LicenseDongle-protected

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Which instrument does PaperManager work with?

PaperManager works only with the CM-3630A spectrophotometer, which has d:0° measurement geometry. This geometry is the measurement condition required by the ISO brightness and opacity standards of the paper industry.

What is the difference between ISO brightness (R457) and CIE whiteness?

ISO brightness is the reflectance factor measured in the blue region around 457 nm and indicates the degree of bleaching of pulp and paper. CIE whiteness takes the entire visible region into account and expresses whiteness as perceived by the eye.

Can deinking be measured on recycled paper?

Yes. The software calculates deinking efficiency as a percentage according to the INGEDE method.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote