Konica Minolta
PaperManager Paper and Pulp Measurement Software
PaperManager is paper measurement software developed for the pulp and paper industry that calculates color and optical properties. Together with the CM-3630A spectrophotometer with d:0° geometry, it calculates ISO brightness, CIE whiteness, opacity and color values in accordance with industry standards.
Request a quote| Compatible instrument | CM-3630A spectrophotometer (d:0°) |
|---|---|
| Measured | ISO brightness, CIE whiteness and tint, opacity, color |
| Standards | ISO 2469, 2470, 2471, 5631, 11475 |
| Operating system | Windows 7, 8 and 10 |
| License | Dongle-protected |
Product description
PaperManager is dedicated software developed for daily quality control measurements in paper and pulp laboratories. It was developed by NoviProfibre, which has long served the paper industry, and is based on the current color measurement standards of the sector.
The software works only with the CM-3630A paper spectrophotometer. When used together with this instrument, which has d:0° measurement geometry, it forms a measurement system fully compliant with paper-industry-specific standards such as ISO 2469 and ISO 2470.
Measurements are stored in a database, and by defining user profiles, separate measurement layouts can be created for different products or production lines. The screen design can be customized by the user, and the software can be operated with a touchscreen.
Applications
- ISO brightness and CIE whiteness measurement of paper and board
- Brightness and color monitoring of pulp
- Opacity and transparency measurement of paper
- Evaluation of fluorescence effects in products containing optical brightening agents
- Measuring deinking performance on recycled paper
- Daily quality control and reporting of production line samples
Key features
Calculations specific to the paper industry
In addition to CIELAB, Hunter Lab, XYZ, Yxy and Rx, Ry and Rz color values, the software calculates CIE whiteness and tint, ISO brightness (R457, TAPPI), opacity, transparency, and light absorption and scattering coefficients. For recycled paper, deinking efficiency is given as a percentage according to the INGEDE method.
UV calibration
UV calibration is performed for CIE whiteness and tint, ISO brightness and spectral profile data. This ensures that measurements on papers containing optical brightening agents are made with a defined UV content.
Supported standards
The software supports the methods for reflectance factor (ISO 2469), ISO brightness (ISO 2470), opacity (ISO 2471), pulp brightness (ISO 3688), color determination under different illuminants (ISO 5631-1, -2, -3), light scattering and absorption coefficients (ISO 9416), CIE whiteness (ISO 11475), indoor whiteness (ISO 11476), as well as ISO 12625-7 and ISO 12625-15 for tissue products.
Selection criteria for paper measurement software
In paper and pulp laboratories, PaperManager should be planned together with the CM-3630A. For general color quality control of non-paper products or with other Konica Minolta instruments, SpectraMagic NX2 is the more suitable software.
The software is licensed via USB dongle and is stated to be compatible with Windows 7, 8 and 10. The operating system of the computer on which it will be installed should be checked before ordering.
Other models in the category are listed under color and gloss measuring instruments. Test methods used in the paper industry are also published by TAPPI.
Technical specifications
| Compatible instrument | CM-3630A (d:0° geometry) |
|---|---|
| Developer | NoviProfibre |
| Color values | CIELAB, Hunter Lab, XYZ, Yxy, Rx / Ry / Rz |
| Whiteness and brightness | CIE whiteness and tint; ISO brightness R457 (TAPPI) |
| Optical properties | Opacity, transparency, light absorption and scattering coefficients |
| Recycling | INGEDE deinking (IE700, %) |
| Calibration | UV calibration for CIE whiteness and tint, ISO brightness and spectral profile |
| ISO standards | ISO 2469, 2470, 2471, 3688, 5631-1, 5631-2, 5631-3, 9416, 11475, 11476, 12625-7, 12625-15 |
| Data management | Measurement storage in a database, user profiles |
| Interface | User-customizable screen, touchscreen support |
| Operating system | Windows 7, 8 and 10 |
| License | Dongle-protected |
Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.
Frequently asked questions
Which instrument does PaperManager work with?
PaperManager works only with the CM-3630A spectrophotometer, which has d:0° measurement geometry. This geometry is the measurement condition required by the ISO brightness and opacity standards of the paper industry.
What is the difference between ISO brightness (R457) and CIE whiteness?
ISO brightness is the reflectance factor measured in the blue region around 457 nm and indicates the degree of bleaching of pulp and paper. CIE whiteness takes the entire visible region into account and expresses whiteness as perceived by the eye.
Can deinking be measured on recycled paper?
Yes. The software calculates deinking efficiency as a percentage according to the INGEDE method.
From the same category

CM-26dG / CM-26d Portable Spectrophotometer
Portable spectrophotometer that captures color and 60° gloss in a single measurement and measures SCI and SCE simultaneously.

CM-25d Portable Spectrophotometer
Single-aperture portable spectrophotometer that measures SCI and SCE simultaneously and operates in the 400–700 nm range.

CM-23d Portable Spectrophotometer
Entry-level portable spectrophotometer that measures SCI and SCE values together for basic color quality control.

CM-17d / CM-16d Portable Spectrophotometer
Next-generation portable spectrophotometer with vertical body, camera viewfinder and interchangeable apertures.
Request a quote for this model
A suitable configuration and pricing are prepared based on sample type and workload.
Request a quote