DUKO LifeDUKO Life
Konica Minolta CM-3630A paper spectrophotometer

Konica Minolta

CM-3630A Paper and Pulp Spectrophotometer

The CM-3630A is a paper spectrophotometer with a vertical body, designed for whiteness and color measurement in the paper and pulp industry. It offers d:0° geometry, numerical UV control with three xenon lamps and two measurement apertures.

Request a quote
Geometryd:0° (ISO 2469, DIN 53145)
Wavelength360–740 nm, 10 nm pitch
UV adjustmentUV100, UV0, adjusted; 400 and 420 nm filters
Measurement apertureLAV Ø30 mm, MAV Ø8 mm
RepeatabilityΔE*ab 0.02

Product description

The CM-3630A is a paper spectrophotometer designed around the d:0° measurement geometry used by paper and pulp laboratories. Its measurement conditions conform to ISO 2469, JIS P8148, DIN 53145-1 and DIN 53145-2; whiteness and color values can therefore be compared directly with the industry's established test methods.

In paper production, the effect of optical brighteners depends on the UV content of the measuring light. The three pulsed xenon lamps and numerical UV control (NUVC) of the CM-3630A generate UV100, UV0 and adjusted UV conditions instantly, without mechanical filter movement. This allows the contribution of optical brighteners to be separated quickly and reproducibly.

The vertical body makes it easy to place paper sheets at the sample port. The built-in camera, used with suitable software, displays the measurement spot.

In addition to ISO standards, results can be reported according to the TAPPI, SCAN, CPPA, DIN and AFNOR methods common in the paper industry. ISO brightness (ISO 2470), opacity, fluorescence, whiteness and tint values are evaluated on a single screen with PaperManager software.

Applications

The manufacturer positions the instrument for the pulp and paper industry.

  • Whiteness measurement of paper and board
  • Comparison of UV-included and UV-excluded measurements for products containing optical brighteners
  • Color and whiteness monitoring of pulp
  • Color difference control of colored paper and packaging board
  • Paper-industry-specific reporting of measurement results with PaperManager software

Technical evaluation of the paper spectrophotometer

The measurement area is selected between LAV (Ø30 mm) and MAV (Ø8 mm). The large aperture averages out the variability caused by the fibrous, non-uniform structure of paper and gives a more representative result; the small aperture is suitable for narrow strips and label samples.

Repeatability is specified as ΔE*ab 0.02 on the white calibration plate and 0.1% in spectral reflectance, with inter-instrument agreement of ΔE*ab 0.2. A measurement is completed within 1.5 seconds; the interval between measurements is 2 seconds for UV100 and 3 seconds for UV0 and adjusted UV.

The paper-industry-specific PaperManager software can be used for data evaluation. The instrument connects to a computer via USB 2.0.

For paper samples, one of the factors with the greatest influence on the result is the opacity of the sample and the background behind it. Reflectance measurements are therefore taken on an opaque pad made of the number of sheets specified by the method, and samples are protected from fingerprints.

Selection criteria

If reflectance and transmittance measurement with d:8° geometry is required for materials other than paper, the CM-3700A Plus or the CM-36dG series is more suitable. For high-speed, non-contact at-line measurement, the CF-300 can be considered.

Other models in the category are listed under color and gloss measuring instruments. Test methods used in the paper industry are also published by TAPPI.

Technical specifications

GeometryReflectance d:0° (diffuse illumination, 0° viewing); ISO 2469, JIS P8148, DIN 53145-1, DIN 53145-2
DetectorDual 40-element silicon photodiode array, diffraction grating
Wavelength range360–740 nm, 10 nm pitch
Reflectance range0–200%, resolution 0.01%
Light source3 pulsed xenon lamps
Measurement timeWithin 1.5 s
Interval between measurementsUV100: within 2 s; UV0 / adjusted UV: within 3 s
Measurement / illumination areaLAV Ø30/34 mm; MAV Ø8/11 mm
RepeatabilityΔE*ab 0.02; spectral reflectance 0.1%
Inter-instrument agreementΔE*ab 0.2 (average of 12 BCRA Series II tiles)
UV adjustment100% / 0% / adjusted; 400 nm and 420 nm UV cut filters (NUVC)
ViewfinderBuilt-in camera; requires software (not included)
InterfaceUSB 2.0 Full Speed
SoftwarePaperManager (for the paper industry)
Operating environment13–33 °C, 80% relative humidity or less, non-condensing
Dimensions / weight300 × 612 × 315 mm; 16 kg

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

Why is d:0° geometry used for paper measurement?

Whiteness and reflectance factor test methods in the paper and pulp industry are based on d:0° geometry. An instrument measuring with this geometry delivers results that can be compared directly with industry standards.

How does numerical UV control differ from a mechanical filter?

With numerical UV control, the UV100, UV0 and adjusted UV conditions are obtained by computationally combining the measurements of three xenon lamps. Because no filter movement is required, switching between conditions is fast and there is no mechanical wear.

Which measurement aperture should be selected?

The Ø30 mm LAV is used for standard paper samples to reduce the variability caused by the fiber structure. The Ø8 mm MAV is preferred for narrow or small samples.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote