DUKO LifeDUKO Life
Texture analyzer with compression and tension modes

Viscosity and Rheology

Texture Analyzer

The texture analyzer measures force in compression and tension mode. It offers interchangeable load cells from 10 N to 500 N, a speed of 0.1–10 mm/s, 200 mm travel and compression, relaxation, tension, TPA cycle and penetrometry modes.

Request a quote
Load cells10 · 20 · 50 · 100 · 250 · 500 N
Resolution0.001 N (10–100 N) · 0.01 N (250–500 N)
Speed0.1–10 mm/s, ±0.2%
Travel200 mm, 0.1 mm resolution
ModesCompression, relaxation, tension, TPA, penetrometry

Product description

The texture analyzer quantifies the physical structure of a product through force measurement. Sensory attributes such as hardness, springiness, adhesiveness, chewiness and fracturability are converted into measurable force-distance data.

The instrument operates in compression and tension directions. The measuring probe descends onto the sample at a defined speed, presses to a defined depth, and the force-distance curve is recorded. The quantities calculated from the curve describe the structural properties of the product.

Sensory panel evaluations are subjective and costly, and a panel cannot be expected to give the same result every time. Texture analysis measures the same properties numerically and repeatably. The panel is not eliminated entirely, but routine control is performed with the instrument.

The load cell is interchangeable. With the 10 N cell, very soft products are measured at a resolution of 0.001 N, while the 500 N cell is used for hard and resistant samples. Choosing the right cell is the first step that determines measurement quality.

Operating modes

Compression

The probe is pressed into the sample to a defined depth. The maximum force measured is an indicator of hardness. This is the most commonly used mode.

Relaxation

The sample is held at a given deformation and the decrease in force over time is monitored. It is an indicator of viscoelastic behavior and is used for gel and dough systems.

Tension

Force is measured as the probe moves away from the sample. Adhesiveness and extensibility are determined in this mode. It is preferred for adhesives and gel systems.

TPA cycle

Texture profile analysis compresses the sample twice in succession. Hardness, adhesiveness, springiness, cohesiveness, gumminess and chewiness are calculated from the resulting two-peak curve. It is the most widely used analysis method in the food industry.

Penetrometry

A thin probe is pushed into the sample and the penetration resistance is measured. Fruit ripeness, gel firmness and paste consistency are evaluated in this mode.

All modes are available on the same instrument. The measurement method is stored; the same product is measured every time with the same probe, speed and depth.

Probe and fixture selection

The second factor that determines the result is the probe. The probe geometry directly defines the quantity being measured; the same sample gives different results with different probes.

  • Cylindrical probes: General-purpose compression measurements; the diameter is selected according to sample size.
  • Needle and conical probes: Penetrometry; gels, butter and paste-like products.
  • Blade and cutting fixtures: Cutting resistance of meat, vegetables and dough products.
  • Three-point bending fixture: Fracturability of biscuits, crackers and crisp products.
  • Extrusion cells: Back extrusion of fluid and semi-solid products.
  • Tensile grips: Elongation and break of films, gels and adhesives.

Custom probes can be manufactured; material, shape and dimensions are determined according to the sample type. The integrated rotating table is Ø160 mm; the fixture mounting table measures 120 × 220 mm.

Applications of the texture analyzer

  • Food: Softness of bread and bakery products, tenderness of meat, sliceability of cheese, springiness of gummy candies, fracturability of chocolate.
  • Cosmetics: Spreadability and hardness of creams and stick products.
  • Pharmaceutical: Tablet hardness, consistency of gels and ointments, strength of film coatings.
  • Packaging: Opening force and tear resistance of films and closure systems.
  • Polymers and adhesives: Tack, breaking strength and elastic recovery.

For flow behavior and viscosity measurement, the rotational rheometer, and for moisture control in food products, the halogen moisture analyzer can be used as complementary instruments. Other instruments are in the viscosity and rheology category.

Technical specifications

Load cells10 N · 20 N · 50 N · 100 N · 250 N · 500 N
Resolution0.001 N (10–100 N) · 0.01 N (250–500 N)
Accuracy0.5% of full scale
Speed0.1–10 mm/s, ±0.2%
Travel200 mm, 0.1 mm resolution
Operating modesCompression, relaxation, tension, TPA cycle, penetrometry, relative compression
TemperaturePT100, -50 °C … +300 °C
Rotating tableØ160 mm, height-adjustable
Fixture table120 × 220 mm
Display7-inch color touchscreen
Data outputRS232, USB; PCL/5-compatible printer
CalibrationCalibration kits according to load cell class
DimensionsØ610 × W340 × H710 mm
Weight25 kg
Power supply90–240 VAC, 50/60 Hz

Values are taken from the manufacturer's published technical documentation. They may vary by configuration and are confirmed against the current datasheet before quotation.

Frequently asked questions

What does TPA analysis measure?

Texture profile analysis compresses the sample twice and calculates hardness, adhesiveness, springiness, cohesiveness, gumminess and chewiness in a single run. It is the standard method for quantifying sensory attributes in the food industry.

Which load cell should be selected?

The measured force should remain between 10% and 90% of the cell's full scale. A 10 N cell is used for very soft products, and a 250 N or 500 N cell for hard and resistant samples. If different product groups are tested, more than one cell is recommended; the cell is interchangeable.

Does probe selection affect the result?

Directly. The same sample gives different force values with probes of different geometry. For this reason, probe, speed and depth are defined as a method and kept the same for all measurements.

Does it replace a sensory panel?

For routine control, largely yes. The panel measures consumer perception; the instrument measures physical structure. The right approach is to establish a correlation between panel and instrument results once and then carry out routine control with the instrument.

Can custom probes be made?

Yes. Custom probes can be manufactured with material, shape and dimensions determined according to the sample type. This approach is used for non-standard sample geometries.

How are results reported?

Measurement methods are stored on the instrument; results are exported via USB flash drive or sent to a PCL/5-compatible printer. With optional software, PC control and advanced data processing are possible.

What is the measurement accuracy?

Accuracy is 0.5% of full scale for force measurement and ±0.2% for speed control. Travel resolution is 0.1 mm.

Request a quote for this model

A suitable configuration and pricing are prepared based on sample type and workload.

Request a quote